Full-Feedforward Schemes of Grid Voltages for a Three-Phase LCL-Type Grid-Connected Inverter

被引:159
作者
Li, Weiwei [1 ]
Ruan, Xinbo [1 ,2 ]
Pan, Donghua [1 ]
Wang, Xuehua [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Aeropower Sci Tech Ctr, Nanjing 210016, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Feedforward; grid-connected inverter; LCL filter; total harmonic distortion (THD); CURRENT CONTROLLER; POWER-GENERATION; FILTER; CONVERTERS; DISTORTION; DESIGN;
D O I
10.1109/TIE.2012.2193864
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper investigates the feedforward schemes of grid voltages for a three-phase LCL-type grid-connected inverter. The full-feedforward functions of grid voltages are derived for the stationary alpha - beta frame, synchronous d - q frame, and decoupled synchronous d - q frame-controlled three-phase LCL-type grid-connected inverters. The derived full-feedforward functions mainly consist of three parts which are proportional, derivative, and second derivative parts. The use of the traditional proportional feedforward function in the three-phase LCL-type grid-connected inverter will result in the amplification of the high-frequency injected grid current harmonics. With the proposed full-feedforward schemes, the injected grid current harmonics and unbalance caused by grid voltages can be greatly reduced. The effectiveness of the proposed feedforward schemes is verified by the experimental results.
引用
收藏
页码:2237 / 2250
页数:14
相关论文
共 25 条
[1]   Suppression of line voltage related distortion in current controlled grid connected inverters [J].
Abeyasekera, T ;
Johnson, CM ;
Atkinson, DJ ;
Armstrong, M .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) :1393-1401
[2]  
[Anonymous], CONTROL SYSTEM DESIG
[3]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[4]   Characterisation of voltage sags experienced by three-phase adjustable-speed drives [J].
Bollen, MHJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) :1666-1671
[5]  
Dahono PA, 2002, IEEE POWER ELECTRON, P1630
[6]   Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters [J].
Dannehl, Joerg ;
Fuchs, Friedrich Wilhelm ;
Hansen, Steffan ;
Thogersen, Paul Bach .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (04) :1509-1517
[7]   Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter [J].
Figueres, Emilio ;
Garcera, Gabriel ;
Sandia, Jesus ;
Gonzalez-Espin, Francisco ;
Calvo Rubio, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (03) :706-717
[8]   Optimized Design of Stationary Frame Three Phase AC Current Regulators [J].
Holmes, D. G. ;
Lipo, T. A. ;
McGrath, B. P. ;
Kong, W. Y. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (11) :2417-2426
[9]   An Improved Maximum Power Point Tracking for Photovoltaic Grid-Connected Inverter Based on Voltage-Oriented Control [J].
Kadri, Riad ;
Gaubert, Jean-Paul ;
Champenois, Gerard .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (01) :66-75
[10]  
KIM JS, 1993, IEEE POWER ELECTRON, P300, DOI 10.1109/PESC.1993.471913