A systematic comparison of motion artifact correction techniques for functional near-infrared spectroscopy

被引:333
作者
Cooper, Robert J. [1 ]
Seib, Juliette [1 ]
Gagnon, Louis [1 ,2 ,3 ]
Phillip, Dorte [4 ]
Schytz, Henrik W. [4 ]
Iversen, Helle K. [4 ,5 ]
Ashina, Messoud [4 ]
Boas, David A. [1 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Radiol,Athinoula A Martinos Ctr Biomed Imagi, Charlestown, MA 02129 USA
[2] Harvard MIT Div Hlth Sci & Technol, Cambridge, MA USA
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[4] Univ Copenhagen, Fac Hlth Sci, Glostrup Hosp, Danish Headache Ctr,Dept Neurol, Copenhagen, Denmark
[5] Univ Copenhagen, Fac Hlth Sci, Glostrup Hosp, Stroke Unit,Dept Neurol, Copenhagen, Denmark
关键词
near-infrared spectroscopy; functional near-infrared spectroscopy; NIRS; motion artifact; hemodynamic response;
D O I
10.3389/fnins.2012.00147
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Near-infrared spectroscopy (NIRS) is susceptible to signal artifacts caused by relative motion between NIRS optical fibers and the scalp. These artifacts can be very damaging to the utility of functional NIRS, particularly in challenging subject groups where motion can be unavoidable. A number of approaches to the removal of motion artifacts from NIRS data have been suggested. In this paper we systematically compare the utility of a variety of published NIRS motion correction techniques using a simulated functional activation signal added to 20 real NIRS datasets which contain motion artifacts. Principle component analysis, spline interpolation, wavelet analysis, and Kalman filtering approaches are compared to one another and to standard approaches using the accuracy of the recovered, simulated hemodynamic response function (HRF). Each of the four motion correction techniques we tested yields a significant reduction in the mean-squared error (MSE) and significant increase in the contrast-to-noise ratio (CNR) of the recovered HRF when compared to no correction and compared to a process of rejecting motion-contaminated trials. Spline interpolation produces the largest average reduction in MSE (55%) while wavelet analysis produces the highest average increase in CNR (39%). On the basis of this analysis, we recommend the routine application of motion correction techniques (particularly spline interpolation or wavelet analysis) to minimize the impact of motion artifacts on functional NI RS data.
引用
收藏
页数:10
相关论文
共 25 条
[1]   Automatic Detection of Motion Artifacts in Infant Functional Optical Topography Studies [J].
Blasi, Anna ;
Phillips, Derrick ;
Lloyd-Fox, Sarah ;
Koh, Peck Hui ;
Elwell, Clare E. .
OXYGEN TRANSPORT TO TISSUE XXXI, 2010, 662 :279-284
[2]   Transient haemodynamic events in neurologically compromised infants: A simultaneous EEG and diffuse optical imaging study [J].
Cooper, R. J. ;
Hebden, Jeremy C. ;
O'Reilly, H. ;
Mitra, S. ;
Michell, A. W. ;
Everdell, N. L. ;
Gibson, A. P. ;
Austin, T. .
NEUROIMAGE, 2011, 55 (04) :1610-1616
[3]   Functional near infrared spectroscopy (NIRS) signal improvement based on negative correlation between oxygenated and deoxygenated hemoglobin dynamics [J].
Cui, Xu ;
Bray, Signe ;
Reiss, Allan L. .
NEUROIMAGE, 2010, 49 (04) :3039-3046
[4]   Hemodynamic evoked response of the sensorimotor cortex measured noninvasively with near-infrared optical imaging [J].
Franceschini, MA ;
Fantini, S ;
Thomspon, JH ;
Culver, JP ;
Boas, DA .
PSYCHOPHYSIOLOGY, 2003, 40 (04) :548-560
[5]   Short separation channel location impacts the performance of short channel regression in NIRS [J].
Gagnon, Louis ;
Cooper, Robert J. ;
Yuecel, Meryem A. ;
Perdue, Katherine L. ;
Greve, Douglas N. ;
Boas, David A. .
NEUROIMAGE, 2012, 59 (03) :2518-2528
[6]   Improved recovery of the hemodynamic response in diffuse optical imaging using short optode separations and state-space modeling [J].
Gagnon, Louis ;
Perdue, Katherine ;
Greve, Douglas N. ;
Goldenholz, Daniel ;
Kaskhedikar, Gayatri ;
Boas, David A. .
NEUROIMAGE, 2011, 56 (03) :1362-1371
[7]  
Grewal M. S., 2003, KALMAN FILTERING THE
[8]   HomER: a review of time-series analysis methods for near-infrared spectroscopy of the brain [J].
Huppert, Theodore J. ;
Diamond, Solomon G. ;
Franceschini, Maria A. ;
Boas, David A. .
APPLIED OPTICS, 2009, 48 (10) :D280-D298
[9]   Motion artifact cancellation in NIR spectroscopy using Wiener filtering [J].
Izzetoglu, M ;
Devaraj, A ;
Bunce, S ;
Onaral, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (05) :934-938
[10]   Motion artifact cancellation in NIR spectroscopy using discrete Kalman filtering [J].
Izzetoglu, Meltem ;
Chitrapu, Prabhakar ;
Bunce, Scott ;
Onaral, Banu .
BIOMEDICAL ENGINEERING ONLINE, 2010, 9