Motor cortex activation by H-coil and figure-8 coil at different depths. Combined motor threshold and electric field distribution study

被引:66
作者
Roth, Yiftach [1 ]
Pell, Gaby S. [1 ]
Chistyakov, Andrei V. [2 ,3 ]
Sinai, Alon [2 ,4 ]
Zangen, Abraham [1 ]
Zaaroor, Menashe [2 ,3 ]
机构
[1] Ben Gurion Univ Negev, Dept Life Sci, IL-84105 Beer Sheva, Israel
[2] Rambam Hlth Care Campus, Dept Neurosurg, Haifa, Israel
[3] Technion Israel Inst Technol, Fac Med, Haifa, Israel
[4] Rambam Hlth Care Campus, Dept Neurol, Haifa, Israel
关键词
Transcranial magnetic stimulation; H-coil; Motor threshold; Electric field; Hand motor cortex; Leg motor cortex; TRANSCRANIAL MAGNETIC STIMULATION; DEEP BRAIN-REGIONS; CORTICAL STIMULATION; CONSCIOUS HUMANS; LEG AREA; ADD-ON; MECHANISMS; SITE; LOCALIZATION; FEASIBILITY;
D O I
10.1016/j.clinph.2013.07.013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To compare the ability of an H-coil and figure-8 coil to stimulate different motor cortex regions. Methods: The resting (rMT) and active (aMT) motor thresholds were measured for the right hand APB and leg AHB muscles in 10 subjects, using an H-coil and a figure-8 coil. The electric field distribution induced by the coils was measured in a head model. The combination of the hand and leg MTs with the field measurements was used to determine the depth of hand and leg motor areas via the intersection points. Results: The rMT and aMT of both APB and AHB were significantly lower for the H-coil. The ratio and difference between the leg and hand rMT and aMT were significantly lower for the H-Coil. Electric field measurements revealed significantly more favorable depth profile and larger volume of stimulation for the H-coil. The averaged intersection for the APB was at a distance from coil of 1.83 +/- 0.54 cm and at an intensity of 97.8 +/- 21.4 V/m, while for the AHB it was at a distance of 2.73 +/- 0.44 cm and at an intensity of 118.6 +/- 21.3 V/m. Conclusion: The results suggest a more efficient activation of deeper motor cortical regions using the H-coil. Significance: The combined evaluation of MTs by H-and figure-8 coils allows measurement of the individual depth of different motor cortex regions. This could be helpful for optimizing stimulation parameters for TMS treatment. (C) 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:336 / 343
页数:8
相关论文
共 43 条
[1]   Localization of functional regions of human mesial cortex by somatosensory evoked potential recording and by cortical stimulation [J].
Allison, T ;
McCarthy, G ;
Luby, M ;
Puce, A ;
Spencer, DD .
EVOKED POTENTIALS-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1996, 100 (02) :126-140
[2]   Electric field depth-focality tradeoff in transcranial magnetic stimulation: Simulation comparison of 50 coil designs [J].
Deng, Zhi-De ;
Lisanby, Sarah H. ;
Peterchev, Angel V. .
BRAIN STIMULATION, 2013, 6 (01) :1-13
[3]   The physiological basis of transcranial motor cortex stimulation in conscious humans [J].
Di Lazzaro, V ;
Oliviero, A ;
Pilato, F ;
Saturno, E ;
Dileone, M ;
Mazzone, P ;
Insola, A ;
Tonali, PA ;
Rothwell, JC .
CLINICAL NEUROPHYSIOLOGY, 2004, 115 (02) :255-266
[4]   Descending spinal cord volleys evoked by transcranial magnetic and electrical stimulation of the motor cortex leg area in conscious humans [J].
Di Lazzaro, V ;
Oliviero, A ;
Profice, P ;
Meglio, M ;
Cioni, B ;
Tonali, P ;
Rothwell, JC .
JOURNAL OF PHYSIOLOGY-LONDON, 2001, 537 (03) :1047-1058
[5]   ELECTRIC-FIELD INDUCED IN A SPHERICAL VOLUME CONDUCTOR FROM ARBITRARY COILS - APPLICATION TO MAGNETIC STIMULATION AND MEG [J].
EATON, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (04) :433-440
[6]   LOCALIZING THE SITE OF MAGNETIC BRAIN-STIMULATION IN HUMANS [J].
EPSTEIN, CM ;
SCHWARTZBERG, DG ;
DAVEY, KR ;
SUDDERTH, DB .
NEUROLOGY, 1990, 40 (04) :666-670
[7]   Reply to "Motor evoked potential latency, motor threshold and electric field measurements as indices of transcranial magnetic stimulation depth" [J].
Fadini, Tommaso ;
Matthaeus, Lars ;
Rothkegel, Holger ;
Sommer, Martin ;
Tergau, Frithjof ;
Schweikard, Achim ;
Paulus, Walter ;
Nitsche, Michael .
CLINICAL NEUROPHYSIOLOGY, 2010, 121 (02) :258-259
[8]   H-coil: Induced electric field properties and input/output curves on healthy volunteers, comparison with a standard figure-of-eight coil [J].
Fadini, Tommaso ;
Matthaeus, Lars ;
Rothkegel, Holger ;
Sommer, Martin ;
Tergau, Frithjof ;
Schweikard, Achim ;
Paulus, Walter ;
Nitsche, Michael A. .
CLINICAL NEUROPHYSIOLOGY, 2009, 120 (06) :1174-1182
[9]   A practical guide to diagnostic transcranial magnetic stimulation: Report of an IFCN committee [J].
Groppa, S. ;
Oliviero, A. ;
Eisen, A. ;
Quartarone, A. ;
Cohen, L. G. ;
Mall, V. ;
Kaelin-Lang, A. ;
Mima, T. ;
Rossi, S. ;
Thickbroom, G. W. ;
Rossini, P. M. ;
Ziemann, U. ;
Valls-Sole, J. ;
Siebner, H. R. .
CLINICAL NEUROPHYSIOLOGY, 2012, 123 (05) :858-882
[10]   H-coil repetitive transcranial magnetic stimulation for the treatment of bipolar depression: an add-on, safety and feasibility study [J].
Harel, Eiran Vadim ;
Zangen, Abraham ;
Roth, Yiftach ;
Reti, Irving ;
Braw, Yoram ;
Levkovitz, Yechiel .
WORLD JOURNAL OF BIOLOGICAL PSYCHIATRY, 2011, 12 (02) :119-126