Robust ballistocardiogram acquisition for home monitoring

被引:191
作者
Inan, O. T. [1 ]
Etemadi, M. [1 ]
Wiard, R. M. [2 ]
Giovangrandi, L. [1 ]
Kovacs, G. T. A. [1 ,3 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Med, Stanford, CA 94305 USA
关键词
ballistocardiogram; home monitoring; heart monitoring; heart failure management; NOISE RATIO; SIGNAL;
D O I
10.1088/0967-3334/30/2/005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The ballistocardiogram (BCG) measures the reaction of the body to cardiac ejection forces, and is an effective, non-invasive means of evaluating cardiovascular function. A simple, robust method is presented for acquiring high-quality, repeatable BCG signals from a modified, commercially available scale. The measured BCG waveforms for all subjects qualitatively matched values in the existing literature and physiologic expectations in terms of timing and IJ amplitude. Additionally, the BCG IJ amplitude was shown to be correlated with diastolic filling time for a subject with premature atrial contractions, demonstrating the sensitivity of the apparatus to beat-by-beat hemodynamic changes. The signal-to-noise ratio (SNR) of the BCG was estimated using two methods, and the average SNR over all subjects was greater than 12 for both estimates. The BCG measurement was shown to be repeatable over 50 recordings taken from the same subject over a three week period. This approach could allow patients at home to monitor trends in cardiovascular health.
引用
收藏
页码:169 / 185
页数:17
相关论文
共 32 条
[1]  
ALAMETSA J, 2004, 2 OP ECG WORKSH INT
[2]  
BENJELLOUN H, 1983, EUR J NUCL MED, V8, P206
[3]  
Berne RM., 2001, CARDIOVASCULAR PHYSL, V8th
[4]   ESTIMATING SIGNAL-TO-NOISE RATIO USING SAMPLE CORRELATION COEFFICIENT [J].
BERSHAD, NJ ;
ROCKMORE, AJ .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1974, 20 (01) :112-113
[5]   CLINICAL EVALUATION OF THE BALLISTOCARDIOGRAM .2. HEART DISEASE - HYPERTENSION, ANGINA PECTORIS, AND MYOCARDIAL INFARCTION [J].
CHESKY, K ;
MOSER, M ;
TAYMOR, RC ;
MASTER, AM ;
PORDY, L .
AMERICAN HEART JOURNAL, 1951, 42 (03) :328-333
[6]  
Chung E.K., 1985, ELECTROCARDIOGRAPHY, V3rd
[7]  
Chung E.K., 1989, PRINCIPLES CARDIAC A, V4th
[8]   Drug therapy - The management of chronic heart failure [J].
Cohn, JN .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (07) :490-498
[9]   SIGNAL TO NOISE RATIO AND RESPONSE VARIABILITY MEASUREMENTS IN SINGLE TRIAL EVOKED-POTENTIALS [J].
COPPOLA, R ;
TABOR, R ;
BUCHSBAUM, MS .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1978, 44 (02) :214-222
[10]   SOME OBSERVATIONS ON THE RELATION OF THE HIGH-FREQUENCY BED BALLISTOCARDIOGRAM TO THAT OBTAINED FROM AN APERIODIC BED [J].
DEUCHAR, DC ;
TALBOT, SA ;
SCARBOROUGH, WR .
CIRCULATION, 1955, 11 (02) :228-239