Design and Analysis of a Non-Vision-Based System for Detecting Unstable Gait

被引:0
作者
Chen, Chin-Hsing [1 ]
Yu, Yao-Ming [2 ]
Tan, Sun-Yen [3 ]
Tseng, Hung-Li [4 ]
Huang, Wen-Tzeng [4 ]
机构
[1] Cent Taiwan Univ Sci & Technol, Dept Management Informat Syst, Tainan, Taiwan
[2] Natl Taipei Univ Educ, Dept Math & Informat Educ, Taipei, Taiwan
[3] Natl Taipei Univ Educ, Dept Elect Engn, Taipei, Taiwan
[4] Minghsin Univ Sci & Technol, Dept Comp Sci & Informat Engn, Taipei, Taiwan
来源
MECHATRONICS AND APPLIED MECHANICS II, PTS 1 AND 2 | 2013年 / 300-301卷
关键词
Gait; Prevention vs. treatment; Pressure sensor; 3D accelerometer; Non-vision-based; WALKING; KNEE;
D O I
10.4028/www.scientific.net/AMM.300-301.561
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
An unstable gait provides early warning of more serious conditions. In this study, we propose the use of pressure sensors embedded into a shoe pad along with a 3D accelerometer fastened to the knee. We have implemented a portable gait-measuring device integrated with a ZigBee wireless sensor network. Moreover, the step length, step speed, and step distance are easily calculated in the user interface. These data can then be used to distinguish the seven decision points of a complete gait cycle. Analysis of the gait cycle is done using fuzzy logic. The detected gait phases can be compared with standard gait parameters from the literature. Thus, the analyzed gait parameters can provide early detection of the emergence of an unstable gait. Finally, because our system measures knee flexion angle, it can detect the swing phase of the gait cycle.
引用
收藏
页码:561 / +
页数:2
相关论文
共 11 条
[1]   Gait Evaluation of a Novel Hip Constraint Orthosis With Implication for Walking in Paraplegia [J].
Audu, Musa L. ;
To, Curtis S. ;
Kobetic, Rudi ;
Triolo, Ronald J. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2010, 18 (06) :610-618
[2]   Assessment of foot disease in the home environment of diabetic patients using a new photographic foot imaging deviceet al. [J].
Bus S.A. ;
Hazenberg C.E.V.B. ;
Klein M. ;
Van Baal J.G. .
Journal of Medical Engineering and Technology, 2010, 34 (01) :43-50
[3]  
Chen M.R., 2009, NEW PEDICURE MING RE
[4]   Ambulatory measurement of 3D knee joint angle [J].
Favre, J. ;
Jolles, B. M. ;
Aissaoui, R. ;
Aminian, K. .
JOURNAL OF BIOMECHANICS, 2008, 41 (05) :1029-1035
[5]   Smooth and continuous human gait phase detection based on foot pressure patterns [J].
Kong, Kyoungchul ;
Tomizuka, Masayoshi .
2008 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-9, 2008, :3678-3683
[6]  
OBERG T, 1993, J REHABIL RES DEV, V30, P210
[7]   Application of Force Sensing Resistor (FSR) in Design of Pressure Scanning System for Plantar Pressure Measurement [J].
Rana, N. K. .
SECOND INTERNATIONAL CONFERENCE ON COMPUTER AND ELECTRICAL ENGINEERING, VOL 2, PROCEEDINGS, 2009, :678-685
[8]  
Riley P O, 1999, IEEE Trans Rehabil Eng, V7, P420, DOI 10.1109/86.808945
[9]   Computational Intelligent Gait-Phase Detection System to Identify Pathological Gait [J].
Senanayake, Chathuri M. ;
Senanayake, S. M. N. Arosha .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (05) :1173-1179
[10]  
Smith B P, 1994, Biomed Sci Instrum, V30, P153