False-Positive Mammography and Its Association With Health Service Use

被引:0
作者
Gunn, Christine M. [1 ,2 ,3 ]
Bokhour, Barbara
Battaglia, Tracy A. [1 ,2 ]
Silliman, Rebecca A. [4 ,5 ]
Hanchate, Amresh [6 ]
机构
[1] Boston Med Ctr, Evans Dept Med, Sect Gen Internal Med, Womens Hlth Unit, Boston, MA USA
[2] Womens Hlth Interdisciplinary Res Ctr, Boston, MA USA
[3] Boston Univ, Sch Publ Hlth, Dept Hlth Law Policy & Management, Boston, MA USA
[4] Boston Univ, Sch Publ Hlth, Dept Epidemiol, Boston, MA USA
[5] Boston Univ, Sch Med, Dept Med, Boston, MA 02118 USA
[6] Boston Univ, Sch Med, Sect Gen Internal Med, Boston, MA 02118 USA
关键词
SHARED DECISION-MAKING; BREAST-CANCER; SCREENING MAMMOGRAPHY; INSURANCE REFORM; FAMILY-HISTORY; WOMEN; RISK; EXPERIENCES; CHOICES; IMPACT;
D O I
暂无
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
OBJECTIVES: A false-positive mammogram can result in anxiety, distress, and increased perceptions of breast cancer risk, potentially changing how women utilize healthcare. This study examined whether having an abnormal mammogram, considered a proxy for elevated risk perception, was associated with greater future health service use (outpatient visits and referrals). STUDY DESIGN: A retrospective cohort study using electronic health record data, spanning 2008 to 2012, from Boston Medical Center, a safety-net hospital. METHODS: We grouped 3920 women aged 40 to 75 years receiving primary care and who had a mammogram between 2010 and 2011 into 3 categories: false-positive mammogram at index date; previous false positive, but normal index mammogram; and no history of false-positive mammograms. We contrasted the longitudinal changes in outpatient visits and provider referrals, before versus after the index mammogram, between women with false-positive mammogram and those without using Poisson regression models with a difference-in-differences specification. Clinical, visit, and demographic data were obtained from the institutional clinical data warehouse. RESULTS: Adjusting for baseline differences in sociodemographic characteristics across risk groups and for secular changes between pre- and postindex periods, a current false-positive mammogram was associated with an 18% increase in overall outpatient visits (incidence rate ratio [IRR], 1.18; 95% CI, 1.07-1.51), but no corresponding increase in provider referrals (IRR, 1.15; 95% CI, 0.99-1.34), relative to never having a false positive. A previous false-positive mammogram had no associated change in outpatient utilization (IRR, 0.99; 95% CI, 0.91-1.07). CONCLUSIONS: Providers should discuss the implications of mammography findings at the time of screening to help mitigate potential detrimental effects and promote appropriate engagement in health services.
引用
收藏
页码:131 / +
页数:9
相关论文
共 47 条
[1]  
[Anonymous], ACC CAR ORG 2015 PRO
[2]  
[Anonymous], ANN INTERN MED
[3]  
[Anonymous], 2002, EXPT QUASIEXPERIMENT
[4]  
[Anonymous], 2003, BREAST IM REP DAT SY
[5]   False-positive findings in mammography screening induces shortterm distress - breast cancer-specific concern prevails longer [J].
Aro, AR ;
Absetz, SP ;
van Elderen, TM ;
van der Ploeg, E ;
van der Kamp, LJT .
EUROPEAN JOURNAL OF CANCER, 2000, 36 (09) :1089-1097
[6]  
Barton MB, 2001, J GEN INTERN MED, V16, P150, DOI 10.1046/j.1525-1497.2001.00329.x
[7]   How much should we trust differences-in-differences estimates? [J].
Bertrand, M ;
Duflo, E ;
Mullainathan, S .
QUARTERLY JOURNAL OF ECONOMICS, 2004, 119 (01) :249-275
[8]   Systematic review: The long-term effects of false-positive mammograms [J].
Brewer, Noel T. ;
Salz, Talya ;
Lillie, Sarah E. .
ANNALS OF INTERNAL MEDICINE, 2007, 146 (07) :502-510
[9]   Propensity Score Methods for Confounding Control in Nonexperimental Research [J].
Brookhart, M. Alan ;
Wyss, Richard ;
Layton, J. Bradley ;
Stuerner, Til .
CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2013, 6 (05) :604-611
[10]  
Carney PA, 2003, ANN INTERN MED, V138, P168, DOI 10.7326/0003-4819-138-3-200302040-00008