DANTE-prepared pulse trains: A novel approach to motion-sensitized and motion-suppressed quantitative magnetic resonance imaging

被引:119
作者
Li, Linqing [1 ]
Miller, Karla L. [1 ]
Jezzard, Peter [1 ]
机构
[1] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB Ctr, Oxford OX3 9DU, England
关键词
DANTE; moving spin suppression; flow artifact suppression; black blood imaging; vessel wall imaging; carotid artery imaging; plaque imaging; STATE FREE PRECESSION; BALANCED SSFP SEQUENCES; FOURIER-TRANSFORM NMR; STEADY-STATE; FLOW; ATHEROSCLEROSIS; SATURATION; REDUCTION; ARTIFACTS; PHASE;
D O I
10.1002/mrm.24142
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Delay alternating with nutation for tailored excitation (DANTE) pulse trains are well appreciated as frequency-selective excitation methods in Fourier transform NMR and for spatial tagging in MRI. In this study, nonselective DANTE pulse trains are used in combination with gradient pulses and short repetition times as motion-sensitive preparation modules. We show that while the longitudinal magnetization of static tissue is mostly preserved, flowing spins are largely (or fully) attenuated as they fail to establish transverse steady state due to a spoiling effect caused by flow along the applied gradient. The attenuation of flowing spins is effectively insensitive to spin velocity (above a low threshold) and can be approximately quantified with a simple T1 longitudinal magnetization decay model. The relevant analytical equations for moving spins and static spins during DANTE module application are derived for both transient and steady state epochs. The equations are validated by comparing analytical solutions and numerical Bloch equation simulations against experimental observations in phantoms and in vivo. Based on this contrast mechanism, the application of the DANTE preparation to black blood vessel imaging is proposed. A simple demonstration of DANTE black blood imaging modules shows that it provides excellent blood signal suppression and static tissue signal preservation. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1423 / 1438
页数:16
相关论文
共 28 条
[1]   HEART WALL MOTION - IMPROVED METHOD OF SPATIAL MODULATION OF MAGNETIZATION FOR MR IMAGING [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 172 (02) :349-350
[2]   Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall Imaging in clinically significant atherosclerosis [J].
Balu, Niranjan ;
Chu, Baocheng ;
Hatsukami, Thomas S. ;
Yuan, Chun ;
Yarnykh, Vasily L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) :918-924
[3]   Flow compensation in balanced SSFP sequences [J].
Bieri, O ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) :901-907
[4]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[5]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[6]   EXTRACRANIAL CAROTID ARTERIES - EVALUATION WITH BLACK BLOOD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MATTLE, HP ;
WALLNER, B ;
BAJAKIAN, R ;
KLEEFIELD, J ;
KENT, C ;
SKILLMAN, JJ ;
MENDEL, JB ;
ATKINSON, DJ .
RADIOLOGY, 1990, 177 (01) :45-50
[7]   FAST SELECTIVE BLACK BLOOD MR IMAGING [J].
EDELMAN, RR ;
CHIEN, D ;
KIM, D .
RADIOLOGY, 1991, 181 (03) :655-660
[8]   PHASE AND INTENSITY ANOMALIES IN FOURIER TRANSFORM NMR [J].
FREEMAN, R ;
HILL, HDW .
JOURNAL OF MAGNETIC RESONANCE, 1971, 4 (03) :366-&
[9]   FOURIER TRANSFORM STUDY OF NMR SPIN-LATTICE RELAXATION BY PROGRESSIVE-SATURATION [J].
FREEMAN, R ;
HILL, HDW .
JOURNAL OF CHEMICAL PHYSICS, 1971, 54 (08) :3367-&
[10]  
Gyngell LM, 1988, MAGN RESON IMAGING, V6, P415