Determination of serum alcohol using a disposable biosensor

被引:22
作者
Luo, Peng [2 ]
Liu, Yi [3 ]
Xie, Guoming [2 ]
Xiong, Xingliang
Deng, Shixiong [4 ]
Song, Fangzhou [1 ]
机构
[1] Chongqing Med Univ, Coll Basic Med, Dept Biochem & Mol Biol, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Dept Lab Med, Minist Educ, Key Lab Lab Med Diagnost, Chongqing 400016, Peoples R China
[3] Chongqing Med & Pharmaceut Coll, Dept Med Tech, Chongqing 400030, Peoples R China
[4] Chongqing Med Univ, Coll Basic Med, Inst Forens Med, Chongqing 400016, Peoples R China
关键词
biosensor; scrum alcohol determination; drunk driving;
D O I
10.1016/j.forsciint.2008.06.002
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
This paper presents a disposable biosensor to detect serum alcohol concentration. The proposed biosensor is fabricated using the cross-linking method to immobilize Alcohol Dehydrogenase (ADH) and Nicotinamide Adenine Dinucleotide (NAD(+)) on the screen-printed electrode modified with Meldola's Blue (MB) absorbed on Nafion. It is based on the electrocatalytic properties of MB as,in electron transfer mediator, which can catalyze the oxidation of NADH to NAD(+) at a low oxidizing potential, thus avoiding interferences due to the presence of oxidizable substances in the real serum samples. The biosensor response for alcohol is investigated in terms of pH, buffer solution, temperature and some interferents. It presents the good specificity, reproducibility, stability, accuracy and provides a fast response. The biosensor has been satisfactorily used for the measurement of serum alcohol. (C). 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:192 / 198
页数:7
相关论文
共 32 条
[1]   Biosensors for analysis of ethanol in food: Effect of the pasting liquid [J].
Boujtita, M ;
Chapleau, M ;
ElMurr, N .
ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) :91-96
[2]   Amperometric biosensor for ethanol based on immobilization of alcohol dehydrogenase on a nickel hexacyanoferrate modified microband gold electrode [J].
Cai, CX ;
Xue, KH ;
Zhou, YM ;
Yang, H .
TALANTA, 1997, 44 (03) :339-347
[3]   ELECTROCATALYTIC OXIDATION OF REDUCED NICOTINAMIDE COENZYMES AT METHYLENE GREEN-MODIFIED ELECTRODES AND FABRICATION OF AMPEROMETRIC ALCOHOL BIOSENSORS [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1994, 285 (1-2) :125-133
[4]  
CRIDDLE WJ, 1995, ETHANOL ENCY ANAL SC, V2
[5]  
Custalow Catherine B, 2004, Prehosp Emerg Care, V8, P175, DOI 10.1016/S1090-3127(03)00279-X
[6]  
DONG S, 1991, BIOSENS BIOELECTRON, V7, P215
[7]   Policing the drunk driver: Measuring law enforcement involvement in reducing alcohol-impaired driving [J].
Dula, Chris S. ;
Dwyer, William O. ;
LeVerne, Gilbert .
JOURNAL OF SAFETY RESEARCH, 2007, 38 (03) :267-272
[8]   ELECTROCATALYTIC OXIDATION OF REDUCED NICOTINAMIDE COENZYMES BY GRAPHITE-ELECTRODES MODIFIED WITH AN ADSORBED PHENOXAZINIUM SALT, MELDOLA BLUE [J].
GORTON, L ;
TORSTENSSON, A ;
JAEGFELDT, H ;
JOHANSSON, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 161 (01) :103-120
[9]   The validity of police assessment of driver intoxication in motor vehicle crashes leading to hospitalization [J].
Grossman, DC ;
Mueller, BA ;
Kenaston, T ;
Salzberg, P ;
Cooper, W ;
Jurkovich, GJ .
ACCIDENT ANALYSIS AND PREVENTION, 1996, 28 (04) :435-442
[10]   A new amperometric enzyme electrode for alcohol determination [J].
Gülce, H ;
Gülce, A ;
Kavanoz, M ;
Coskun, H ;
Yildiz, A .