Time and reliability issues associated with automatic vs. manual measurements of Ankle to Brachial pressure Index (ABI) following heavy load exercise

被引:3
作者
Congnard, Florian [1 ]
Bruneau, Antoine [2 ]
Abraham, Pierre [2 ,3 ]
Colas-Ribas, Christophe [2 ]
Picquet, Jean [3 ,4 ]
Noury-Desvaux, Benedicte [1 ]
机构
[1] Phys Act & Sport Learning Inst IFEPSA, Angers, France
[2] Univ Hosp Angers, Lab Sport & Vasc Invest, Angers, France
[3] Univ Med, UMR INSERM CNRS6214 1083, Angers, France
[4] Univ Hosp Angers, Dept Thorac & Cardiovasc Surg, Angers, France
关键词
Ankle Brachial Index; Automatic; Measurements; Exercise; Healthy volunteers; PERIPHERAL ARTERIAL-DISEASE; BLOOD-PRESSURE; OSCILLOMETRIC MEASUREMENT; VALIDATION; PREVALENCE; DEVICE; ENDOFIBROSIS; DIAGNOSIS;
D O I
10.1016/j.jsams.2014.10.007
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives: Ankle to brachial index after heavy load exercise is the most accurate way of diagnosing minor arterial lesions in athletes, such as endofibrosis. The reliability and practical aspects of ankle to brachial index measurements after heavy-load exercise have not been studied. The purpose of this study was to analyze the interest of oscillometric automatic vs. manual Doppler measurements, for the calculation of ankle to brachial index, after heavy-load exercise in athletes. Design: Prospective single-center study. Methods: Fifteen healthy trained athletes performed an incremental test twice. Ankle to brachial index measurements were performed at Rest, as soon as possible after exercise (Rec-0), and then started at the 3rd minute of recovery (Rec-3), by two operators using each one of the two ankle to brachial index measurement methods. Results: Mean times for automatic vs. manual ankle to brachial availability were 99 +/- 18 s vs. 113 +/- 25 s (p = 0.005) and 44 +/- 25 s vs. 53 +/- 12s (p = 0.001) respectively at Rec-0 and Rec-3. Ankle to brachial index values from the two methods were highly correlated (r = 0.89). Mean absolute differences of automatic vs. manual ankle to brachial values from test-retest were 0.04 +/- 0.05 vs. 0.08 +/- 0.08 (p > 0.05) and 0.07 +/- 0.05 vs. 0.09 +/- 0.10 (p > 0.05) at Rest and Rec-0. Conclusions: Automatic method allows obtaining faster and simultaneously post-exercise ankle to brachial index measurement compare to the manual Doppler. This time issue does not result in a significant change in absolute ankle to brachial index values, nor in the absolute differences of these in test-retest. Nevertheless, the test-retest variability of post-exercise ankle to brachial index results seems smaller with the automatic than the manual method. (C) 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:737 / 741
页数:5
相关论文
共 27 条
  • [1] Diagnosis of peripheral arterial disease in general practice: can the ankle-brachial index be measured either by pulse palpation or an automatic blood pressure device?
    Aboyans, V.
    Lacroix, P.
    Doucet, S.
    Preux, P. -M.
    Criqui, M. H.
    Laskar, M.
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2008, 62 (07) : 1001 - 1007
  • [2] Measurement and Interpretation of the Ankle-Brachial Index A Scientific Statement From the American Heart Association
    Aboyans, Victor
    Criqui, Michael H.
    Abraham, Pierre
    Allison, Matthew A.
    Creager, Mark A.
    Diehm, Curt
    Fowkes, F. Gerry R.
    Hiatt, William R.
    Joensson, Bjoern
    Lacroix, Philippe
    Marin, Benoit
    McDermott, Mary M.
    Norgren, Lars
    Pande, Reena L.
    Preux, Pierre-Marie
    Stoffers, H. E.
    Treat-Jacobson, Diane
    [J]. CIRCULATION, 2012, 126 (24) : 2890 - +
  • [3] Pressure measurements at rest and after heavy exercise to detect moderate arterial lesions in athletes
    Abraham, P
    Bickert, S
    Vielle, B
    Chevalier, EM
    Saumet, JL
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 33 (04) : 721 - 727
  • [4] Automated oscillometric determination of the ankle - Brachial index provides accuracy necessary for office practice
    Beckman, JA
    Higgins, CO
    Gerhard-Herman, M
    [J]. HYPERTENSION, 2006, 47 (01) : 35 - 38
  • [5] Ankle brachial index using an automatic blood pressure device in occupational medicine: relevance in routine examination and comparison with Framingham cardio-vascular risk score
    Benchimol, D.
    Pillois, X.
    Oysel-Mestre, M.
    Sagardiluz, P.
    Bonnet, J.
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2012, 66 (09) : 862 - 866
  • [6] Endofibrosis in Athletes: Is a Simple Bedside Exercise Helpful or Sufficient for the Diagnosis?
    Bruneau, Antoine
    Le faucheur, Alexis
    Mahe, Guillaume
    Vielle, Bruno
    Leftheriotis, Georges
    Abraham, Pierre
    [J]. CLINICAL JOURNAL OF SPORT MEDICINE, 2009, 19 (04): : 282 - 286
  • [7] Clairotte C, 2009, DIABETES CARE, V32, P1231, DOI [10.2337/dc08-2015, 10.2337/dc08-2230]
  • [8] THE PREVALENCE OF PERIPHERAL ARTERIAL-DISEASE IN A DEFINED POPULATION
    CRIQUI, MH
    FRONEK, A
    BARRETTCONNOR, E
    KLAUBER, MR
    GABRIEL, S
    GOODMAN, D
    [J]. CIRCULATION, 1985, 71 (03) : 510 - 515
  • [9] Diehm N, 2009, SWISS MED WKLY, V139, P357, DOI smw-12636
  • [10] The long-term prognostic value of the resting and postexercise ankle-brachial index
    Feringa, HHH
    Bax, JJJ
    van Waning, VH
    Boersma, E
    Elhendy, A
    Schouten, O
    Tangelder, MJ
    van Sambeek, MHRM
    van den Meiracker, AH
    Poldermans, D
    [J]. ARCHIVES OF INTERNAL MEDICINE, 2006, 166 (05) : 529 - 535