A high-throughput continuous sample introduction interface for microfluidic chip-based capillary electrophoresis systems

被引:101
作者
Fang, Q [1 ]
Xu, GM [1 ]
Fang, ZL [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310028, Peoples R China
关键词
D O I
10.1021/ac010925c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of efficient sample introduction and pretreatment systems for microfluidic chip-based analytical systems is important for their application to real-life samples. In this work, world-to-chip interfacing was achieved by a novel flow-through sampling reservoir featuring a guided overflow design. The flow-through reservoir was fabricated on a 30 x 60 x 3 mm planar glass chip of crossed-channel design used for capillary electrophoresis separations. The 20-muL sample reservoir was produced from a section of plastic pipet tip and fixed at one end of the sampling channel. Sample change was performed by pumping 80-muL samples sandwiched between air segments at similar to0.48 mL/min flow rate through the flow-through reservoir, introduced from an access hole on the bottom side of the chip. A filter paper collar wrapped tightly around the reservoir guided the overflowing sample solution into a plastic trough surrounding the reservoir and then to waste. The performance of the system was demonstrated in the separation and determination of FITC-labeled arginine, glycine, phenylalanine, and glutamic acid with LIF detection, by continuously introducing a train of different samples through the system without electrical interruption. Employing a separation channel of 4 cm (2-cm effective separation length) and 1.4-kV separation voltage, maximum throughputs of 80/h were achieved with <4.1% carryover and precisions ranging from 1.5% for arginine to 2.6% RSD (n = 11) for glycine. The sampling system was tested in the continuous monitoring of the derivatizing process of amino acids by FITC over a period of 4 h, involving 166 analytical cycles. An outstanding overall precision of 4.8% RSD (n = 166) was achieved for the fluorescein internal standard.
引用
收藏
页码:1223 / 1231
页数:9
相关论文
共 29 条
[1]  
Attiya S, 2001, ELECTROPHORESIS, V22, P318, DOI 10.1002/1522-2683(200101)22:2<318::AID-ELPS318>3.0.CO
[2]  
2-G
[3]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[4]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[5]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[6]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457
[7]   Sequential injection sample introduction microfluidic-chip based capillary electrophoresis system [J].
Fang, Q ;
Wang, FR ;
Wang, SL ;
Liu, SS ;
Xu, SK ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :27-37
[8]  
Fang Z., 1993, FLOW INJECTION SEPAR
[9]   Combination of flow injection with capillary electrophoresis - Part 7. Microchip capillary electrophoresis system with flow injection sample introduction and amperometric detection [J].
Fu, CG ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 2000, 422 (01) :71-79
[10]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897