Biodistribution, kinetics, and biological fate of SPION microbubbles in the rat

被引:38
作者
Barrefelt, Asa [1 ,2 ,3 ]
Saghafian, Maryam [3 ]
Kuiper, Raoul [4 ]
Ye, Fei [5 ]
Egri, Gabriella [6 ]
Klickermann, Moritz [6 ]
Brismar, Torkel B. [1 ,2 ]
Aspelin, Peter [1 ,2 ]
Muhammed, Mamoun [5 ]
Daehne, Lars [6 ]
Hassan, Moustapha [3 ,7 ]
机构
[1] Karolinska Inst, Dept Clin Sci Intervent & Technol, Div Med Imaging & Technol, Stockholm, Sweden
[2] Karolinska Univ Hosp Huddinge, Dept Radiol, SE-14186 Stockholm, Sweden
[3] Karolinska Inst, Dept Lab Med, Stockholm, Sweden
[4] Karolinska Univ Hosp Huddinge, Clin Res Ctr, Karolinska Inst Core Facil Morphol Phenotype Anal, SE-14186 Stockholm, Sweden
[5] Royal Inst Technol, Dept Mat & Nano Phys, Div Funct Mat, Stockholm, Sweden
[6] Surflay Nanotec GmbH, Berlin, Germany
[7] Karolinska Univ Hosp Huddinge, Clin Res Ctr, SE-14186 Stockholm, Sweden
关键词
biodistribution; microbubbles; superparamagnetic iron oxide; pharmacokinetics; magnetic resonance imaging; histopathology; IRON-OXIDE NANOPARTICLES; MRI CONTRAST AGENTS; RATIONAL DESIGN; IN-VIVO; COORDINATION GEOMETRY; COLORECTAL-CANCER; MACROPHAGE UPTAKE; LIVER METASTASES; DRUG; COMPLEXES;
D O I
10.2147/IJN.S49948
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Background: In the present investigation, we studied the kinetics and biodistribution of a contrast agent consisting of poly(vinyl alcohol) (PVA) microbubbles containing superparamagnetic iron oxide (SPION) trapped between the PVA layers (SPION microbubbles). Methods: The biological fate of SPION microbubbles was determined in Sprague-Dawley rats after intravenous administration. Biodistribution and elimination of the microbubbles were studied in rats using magnetic resonance imaging for a period of 6 weeks. The rats were sacrificed and perfusion-fixated at different time points. The magnetic resonance imaging results obtained were compared with histopathologic findings in different organs. Results: SPION microbubbles could be detected in the liver using magnetic resonance imaging as early as 10 minutes post injection. The maximum signal was detected between 24 hours and one week post injection. Histopathology showed the presence of clustered SPION microbubbles predominantly in the lungs from the first time point investigated (10 minutes). The frequency of microbubbles declined in the pulmonary vasculature and increased in pulmonary, hepatic, and splenic macrophages over time, resulting in a relative shift from the lungs to the spleen and liver. Meanwhile, macrophages showed increasing signs of cytoplasmic iron accumulation, initially in the lungs, then followed by other organs. Conclusion: The present investigation highlights the biological behavior of SPION microbubbles, including organ distribution over time and indications for biodegradation. The present results are essential for developing SPION microbubbles as a potential contrast agent and/or a drug delivery vehicle for specific organs. Such a vehicle will facilitate the use of multimodality imaging techniques, including ultrasound, magnetic resonance imaging, and single positron emission computed tomography, and hence improve diagnostics, therapy, and the ability to monitor the efficacy of treatment.
引用
收藏
页码:3241 / 3254
页数:14
相关论文
共 44 条
[1]  
Albukhaty Salim, 2013, Iranian Biomedical Journal, V17, P71, DOI 10.6091/ibj.1114.2013
[2]  
BACON BR, 1987, J LAB CLIN MED, V110, P164
[3]   Multimodality imaging using SPECT/CT and MRI and ligand functionalized 99mTc-labeled magnetic microbubbles [J].
Barrefelt, Asa A. ;
Brismar, Torkel B. ;
Egri, Gabriella ;
Aspelin, Peter ;
Olsson, Annie ;
Oddo, Letizia ;
Margheritelli, Silvia ;
Caidahl, Kenneth ;
Paradossi, Gaio ;
Daehne, Lars ;
Axelsson, Rimma ;
Hassan, Moustapha .
EJNMMI RESEARCH, 2013, 3 :1-14
[4]   Facilitated Monocyte-Macrophage Uptake and Tissue Distribution of Superparmagnetic Iron-Oxide Nanoparticles [J].
Beduneau, Arnaud ;
Ma, Zhiya ;
Grotepas, Cassi B. ;
Kabanov, Alexander ;
Rabinow, Barrett E. ;
Gong, Nan ;
Mosley, R. Lee ;
Dou, Huanyu ;
Boska, Michael D. ;
Gendelman, Howard E. .
PLOS ONE, 2009, 4 (02)
[5]   Towards the rational design of MRI contrast agents: Electron spin relaxation is largely unaffected by the coordination geometry of Gadolinium(III)-DOTA-Type complexes [J].
Borel, Alain ;
Bean, Jonathan F. ;
Clarkson, Robert B. ;
Helm, Lothar ;
Moriggi, Loick ;
Sherry, A. Dean ;
Woods, Mark .
CHEMISTRY-A EUROPEAN JOURNAL, 2008, 14 (09) :2658-2667
[6]   Clearance of iron oxide particles in rat liver - Effect of hydrated particle size and coating material on liver metabolism [J].
Briley-Saebo, Karen C. ;
Johansson, Lars O. ;
Hustvedt, Svein Olaf ;
Haldorsen, Anita G. ;
Bjornerud, Atle ;
Fayad, Zahi A. ;
Ahlstrom, Haakan K. .
INVESTIGATIVE RADIOLOGY, 2006, 41 (07) :560-571
[7]   Long-term imaging effects in rat liver after a single injection of an iron oxide nanoparticle based MR contrast agent [J].
Briley-Sæbo, K ;
Hustvedt, SA ;
Haldorsen, A ;
Bjornerud, A .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (04) :622-631
[8]   Magnetite Nanoparticles Can Be Coupled to Microbubbles to Support Multimodal Imaging [J].
Brismar, Torkel B. ;
Grishenkov, Dmitry ;
Gustafsson, Bjorn ;
Harmark, Johan ;
Barrefelt, Asa ;
Kothapalli, Satya V. V. N. ;
Margheritelli, Silvia ;
Oddo, Letizia ;
Caidahl, Kenneth ;
Hebert, Hans ;
Paradossi, Gaio .
BIOMACROMOLECULES, 2012, 13 (05) :1390-1399
[9]   Towards the Rational Design of MRI Contrast Agents: δ-Substitution of Lanthanide(III) NB-DOTA-Tetraamide Chelates Influences but Does Not Control Coordination Geometry [J].
Carney, Christiane E. ;
Tran, Anh D. ;
Wang, Jing ;
Schabel, Matthias C. ;
Sherry, A. Dean ;
Woods, Mark .
CHEMISTRY-A EUROPEAN JOURNAL, 2011, 17 (37) :10372-10378
[10]   SPION@liposomes hybrid nanoarchitectures with high density SPION association [J].
Floris, Alice ;
Ardu, Andrea ;
Musinu, Anna ;
Piccaluga, Giorgio ;
Fadda, Anna M. ;
Sinico, Chiara ;
Cannas, Carla .
SOFT MATTER, 2011, 7 (13) :6239-6247