In vitro Study on the Dimensional Stability of Interocclusal Recording Materials

被引:0
作者
Cerghizan, Diana [1 ]
Earar, Kamel [2 ]
Scutariu, Mihaela Monica [3 ]
Dimofte, Alina Ramona [2 ]
Grecu, Gina Paunita [2 ]
Janosi, Kinga [1 ]
机构
[1] Univ Med & Pharm Targu Mures, Fac Med Dent, 38 Gh Marinescu Str, Targu Mures 540139, Romania
[2] Dunarea de Jos Univ Galati, Fac Med & Pharm, Dept Dent, 47 Domneasca Str, Galati 800008, Romania
[3] Univ Med & Pharm Grigore T Popa Iasi, Fac Dent Med, 16 Univ Str, Iasi 700115, Romania
关键词
interocclusal relations; silicones; occlusal relations; morphological components; dental prosthetics; THERAPY;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The teeth are found in the alveolar processes of both the upper and lower jaw and they form the two maxillary and mandibular dental arches, the various relations of which support the performance of the dental apparatus functions, one of the most important of which is mastication. These relations are also known as interocclusal relations, among which the moments in which the dento-dental contacts (occlusal relations) play an important role. Maximum intercuspation (MI) is the most frequent mandibulo-cranial functional position with dento-dental contact. The vast majority of functional food incision and mastication cycles end in MI. The highest number of dento-dental contacts, and the largest possible stability and surface of these contacts are also achieved in MI. Given the relative easiness of determination, recording and transfer of the MI position, it is used in many clinical situations to report the models of the two arches. The interocclusal recording materials used in our study were seven silicones, six of which with addition reaction, five with special destination for interocclusal relation determination and a putty-like silicone normally used for dental arch impression - Elite HD and one condensation silicone used for impressions. The reason for choosing the last two materials was the fact that some practitioners frequently use putty-like impression silicone to determine interocclusal relations. According to the findings of the measurements shown in table 1, further to the initial impression process, at the time TO, satisfactory results were obtained both for addition silicones and for condensation silicones, Registrado X-tra being the only recording material which exhibited major deviation from the standard dimension (3 mm). As for the Optosil condensation silicone, we noted a significant increase of the thickness of the material starting with the first hour after impression and reaching considerable values on the 5th day, which were 0.3 mm higher than the standard value. Rigid addition silicones have the lowest dimensional stability; putty-like silicones are frequently used to record interocclusal relations for fixed prosthetics, which is wrong since they grow rapidly and this impedes on the space between the treated tooth and the opposite tooth, the result being a high restoration, which may determine premature contacts. Except for Optosil, which exhibited a continuous increase, most materials may be used to mount models in the simulator after 24 h.
引用
收藏
页码:557 / 564
页数:8
相关论文
共 50 条
  • [21] Synthesis, Radiolabelling and in vitro Stability Study of 99mTc(CO)3+ Labeled Dendrimer PAMAM-Folic Acid Conjugate
    Zhang Yuanqing
    Xu Xiaoping
    Sun Yanhong
    Shen Yumei
    CHINESE JOURNAL OF CHEMISTRY, 2010, 28 (12) : 2447 - 2450
  • [22] In vitro three-dimensional tumor microenvironment models for anticancer drug discovery
    Smalley, Keiran S. M.
    Lioni, Mercedes
    Noma, Kazuhiro
    Haass, Nikolas K.
    Herlyn, Meenhard
    EXPERT OPINION ON DRUG DISCOVERY, 2008, 3 (01) : 1 - 10
  • [23] Effect of Metallic Flask Closure and Investment Materials on the Stability of the Denture Base Resin
    Xediek Consani, Rafael Leonardo
    Mesquita, Marcelo Ferraz
    Correr Sobrinho, Lourenco
    Coelho Sinhoreti, Mario Alexandre
    JOURNAL OF APPLIED POLYMER SCIENCE, 2010, 116 (03) : 1467 - 1474
  • [24] In vitro and in vivo study of a nanoliposomal cisplatin as a radiosensitizer
    Zhang, Xiaomeng
    Yang, Huanjun
    Gu, Ke
    Chen, Jian
    Rui, Mengjie
    Jiang, Guo-Liang
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2011, 6 : 437 - 444
  • [25] Study of Octaplex dosing accuracy: An in vitro analysis
    Patriquin, Christopher J.
    Chin-Yee, Ian H.
    Kovacs, Michael J.
    Lazo-Langner, Alejandro
    Keeney, Michael
    Hsia, Cyrus C.
    THROMBOSIS AND HAEMOSTASIS, 2012, 107 (02) : 248 - 252
  • [26] The effect of dalteparin on thromboelastography in pregnancy: an in vitro study
    Chow, L.
    Carr, A.
    MacKenzie, L.
    Walker, A.
    Archer, D.
    Lee, A.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2016, 28 : 22 - 27
  • [27] Succinylated Polyethylenimine Derivatives Greatly Enhance Polyplex Serum Stability and Gene Delivery In Vitro
    Warriner, Logan W.
    Duke, Joseph R., III
    Pack, Daniel W.
    DeRouchey, Jason E.
    BIOMACROMOLECULES, 2018, 19 (11) : 4348 - 4357
  • [28] Comparative Study of Toxicity of Alkoxyamines In Vitro and In Vivo
    Popova, N. A.
    Sysoeva, G. M.
    Nikolin, V. P.
    Kaledin, V. I.
    Tretyakov, E. V.
    Edeeva, M. V.
    Balakhnin, S. M.
    Lushnikova, E. L.
    Audran, G.
    Mark, S.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2017, 164 (01) : 49 - 53
  • [29] Association of ranibizumab (Lucentis®) or bevacizumab (Avastin®) with dexamethasone and triamcinolone acetonide: An in vitro stability assessment
    Veurink, Marieke
    Stella, Cinzia
    Tabatabay, Cyrus
    Pournaras, Constantin J.
    Gurny, Robert
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2011, 78 (02) : 271 - 277
  • [30] Laser treatment of onychomycosis: an in vitro pilot study
    Hees, Henrik
    Raulin, Christian
    Baeumler, Wolfgang
    JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2012, 10 (12): : 913 - 917