Structural variants of biodegradable polyesterurethane in vivo evoke a cellular and angiogenic response that is dictated by architecture

被引:42
作者
Henry, Jerome A. [1 ,2 ]
Burugapalli, Krishna [1 ,2 ]
Neuenschwander, Peter [3 ]
Pandit, Abhay [1 ,2 ]
机构
[1] Natl Univ Ireland, Dept Mech & Biomed Engn, Galway, Ireland
[2] Natl Univ Ireland, Natl Ctr Biomed Engn Sci, Galway, Ireland
[3] Swiss Fed Inst Technol, Dept Mat, CH-8093 Zurich, Switzerland
关键词
Polyesterurethane; Tissue response; Scaffold; FIBRO-POROUS MESHES; TISSUE-RESPONSE; CIRCULATING FIBROCYTES; SURFACE; MEMBRANES; IMPLANTS; BIOCOMPATIBILITY; POLYMERS; COLLAGEN; CELLS;
D O I
10.1016/j.actbio.2008.08.020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate an in vivo tissue response to a biodegradable polyesterurethane, specifically the cellular and angiogenic response evoked by varying implant architectures in a subcutaneous rabbit implant model. A synthetic biodegradable polyester-urethane was synthesized and processed into three different configurations: a non-porous film, a porous mesh and a porous membrane. Glutaraldehyde cross-linked bovine pericardium was used as a control. Sterile polyesterurethane and control samples were implanted subcutaneously in six rabbits (n = 12). The rabbits were killed at 21 and 63 days and the implant sites were sectioned and histologically stained using haemotoxylin and eosin (H&E), Masson's trichrome, picosirius red and immunostain CD31. The tissue-implant interface thickness was measured from the H&E slides. Stereological techniques were used to quantify the tissue reaction at each time point that included volume fraction of inflammatory cells, fibroblasts, fibrocytes, collagen and the degree of vascularization. Stereological analysis inferred that porous scaffolds with regular topography are better tolerated in vivo compared to non-porous scaffolds, while increasing scaffold porosity promotes angiogenesis and cellular infiltration. The results suggest that this biodegradable polyesterurethane is better tolerated in vivo than the control and that structural variants of biodegradable polyester-urethane in vivo evoke a cellular and angiogenic response that is dictated by architecture. (C) 2008 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:29 / 42
页数:14
相关论文
共 48 条
[1]   Peripheral blood fibrocytes: Differentiation pathway and migration to wound sites [J].
Abe, R ;
Donnelly, SC ;
Peng, T ;
Bucala, R ;
Metz, CN .
JOURNAL OF IMMUNOLOGY, 2001, 166 (12) :7556-7562
[2]   Pitfalls in the use of acetabular reinforcement rings in total hip revision [J].
Bader, R ;
Mittelmeier, W ;
Zeiler, G ;
Tokar, I ;
Steinhauser, E ;
Schuh, A .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (08) :558-563
[3]   In vivo performance of a new biodegradable polyester urethane system used as a nerve guidance channel [J].
Borkenhagen, M ;
Stoll, RC ;
Neuenschwander, P ;
Suter, UW ;
Aebischer, P .
BIOMATERIALS, 1998, 19 (23) :2155-2165
[4]   The use of therapeutic gene eNOS delivered via a fibrin scaffold enhances wound healing in a compromised wound model [J].
Breen, Ailish M. ;
Dockery, Peter ;
O'Brien, Timothy ;
Pandit, Abhay S. .
BIOMATERIALS, 2008, 29 (21) :3143-3151
[5]   CIRCULATING FIBROCYTES DEFINE A NEW LEUKOCYTE SUBPOPULATION THAT MEDIATES TISSUE-REPAIR [J].
BUCALA, R ;
SPIEGEL, LA ;
CHESNEY, J ;
HOGAN, M ;
CERAMI, A .
MOLECULAR MEDICINE, 1994, 1 (01) :71-81
[6]   BOVINE PERICARDIUM - ANOTHER CAUTIONARY NOTE [J].
BULLABOY, CA .
ANNALS OF THORACIC SURGERY, 1989, 48 (05) :743-743
[7]  
Cheney-Coker S, 2004, POETRY WALES, V40, P54
[8]   Collagen in the scarless fetal skin wound: Detection with Picrosirius-polarization [J].
Cuttle, L ;
Nataatmadja, M ;
Fraser, JF ;
Kempf, M ;
Kimble, RM ;
Hayes, MT .
WOUND REPAIR AND REGENERATION, 2005, 13 (02) :198-204
[9]  
DAHN M, 1990, J THORAC CARDIOVASC, V99, P1082
[10]   An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements [J].
Davies, AP ;
Willert, HG ;
Campbell, PA ;
Learmonth, ID ;
Case, CP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :18-27