Optimization of solid-phase microextraction using Taguchi design to quantify trace level polycyclic aromatic hydrocarbons in water

被引:13
作者
Anil, Ismail [1 ,3 ]
Ozturk, Naciye [2 ]
Alagha, Omar [3 ,4 ]
Ergenekon, Pinar [1 ]
机构
[1] Gebze Inst Technol, Dept Environm Engn, TR-41400 Kocaeli, Turkey
[2] Gebze Inst Technol, Dept Chem, TR-41400 Kocaeli, Turkey
[3] Fatih Univ, Dept Environm Engn, Istanbul, Turkey
[4] Univ Dammam, Dept Environm Engn, Dammam, Saudi Arabia
关键词
Method optimization; Polycyclic aromatic hydrocarbons; Solid-phase microextraction; Taguchi experimental design; MICRO-EXTRACTION SPME; GAS-CHROMATOGRAPHY; QUANTITATIVE-ANALYSIS; DEPOSITION; SAMPLES; PAHS; SELECTIVITY; DYNAMICS; COATINGS; MILK;
D O I
10.1002/jssc.201200550
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article introduces a simple, rapid, and reliable solid-phase microextraction (SPME) method coupled with GC-MS for the quantitative determination of 16 polycyclic aromatic hydrocarbons in water. In this study, the Taguchi experimental design was used to optimize extraction conditions of polycyclic aromatic hydrocarbons using SPME method to obtain highly enriched analytes. Consequently, quantitative determination of polycyclic aromatic hydrocarbons in water was achieved by GC-MS technique. The selected parameters affecting enrichment of polycyclic aromatic hydrocarbons were sample extraction time, stirring speed, temperature, ionic strength, and pH. The study revealed that optimal operating conditions were found to be 90-min extraction time, 1400 rpm stirring speed, and 60 degrees C sample temperature. The effect of ionic strength and pH were shown to be insignificant. Optimized conditions were also reevaluated by placing the 16 polycyclic aromatic hydrocarbons into several subgroups based on their molecular weight. The extraction efficiency of polycyclic aromatic hydrocarbons with low molecular weight was shown to be a function of only the extracting temperature. Satisfactory results were obtained for linearity (0.9830.999), detection limits (2.6718.02 ng/L), accuracy (71.299.3%), and precision (4.313.5%). The optimum conditions reported by other design approaches were evaluated and generalized optimum conditions were suggested.
引用
收藏
页码:3561 / 3568
页数:8
相关论文
共 50 条
[21]   Sources and Wet Deposition Fluxes of Polycyclic Aromatic Hydrocarbons (PAHs) in an Urban Site 1000 Meters High in Central Anatolia (Turkey) [J].
Gaga, Eftade O. ;
Tuncel, Guerdal ;
Tuncel, Semra G. .
ENVIRONMENTAL FORENSICS, 2009, 10 (04) :286-298
[22]   Solid phase microextraction-high performance liquid chromatographic determination of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1 3,5-trinitro-1,3,5-triazine (RDX) in the presence of sodium dodecyl sulfate surfactant [J].
Gaurav ;
Malik, Ashok Kumar ;
Rai, Parmod Kumar .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (12) :2173-2181
[23]   Theory of analyte extraction by selected porous polymer SPME fibres [J].
Górecki, T ;
Yu, XM ;
Pawliszyn, J .
ANALYST, 1999, 124 (05) :643-649
[24]   Automation of solid-phase microextraction on a 96-well plate format [J].
Hutchinson, Joseph P. ;
Setkova, Lucie ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1149 (02) :127-137
[25]   Determination of polycyclic aromatic hydrocarbons in water by solid-phase microextraction-gas chromatography-mass spectrometry [J].
King, AJ ;
Readman, JW ;
Zhou, JL .
ANALYTICA CHIMICA ACTA, 2004, 523 (02) :259-267
[26]   The application of solid-phase micro-extraction (SPME) to the analysis of polycyclic aromatic hydrocarbons (PAHs) [J].
King, AJ ;
Readman, JW ;
Zhou, JL .
ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2003, 25 (01) :69-75
[27]   Quantitative analysis of fuel-related hydrocarbons in surface water and wastewater samples by solid-phase microextraction [J].
Langenfeld, JJ ;
Hawthorne, SB ;
Miller, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :144-155
[28]   Evolution of solid-phase microextraction technology [J].
Lord, H ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :153-193
[29]   DYNAMICS OF ORGANIC-COMPOUND EXTRACTION FROM WATER USING LIQUID-COATED FUSED-SILICA FIBERS [J].
LOUCH, D ;
MOTLAGH, S ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1187-1199
[30]   Tuning the selectivity of polymeric ionic liquid sorbent coatings for the extraction of polycyclic aromatic hydrocarbons using solid-phase microextraction [J].
Meng, Yunjing ;
Anderson, Jared L. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (40) :6143-6152