Relationship between transducer type and low-frequency hearing loss for patients with ventilation tubes

被引:2
作者
Tokar-Prejna, S.
Meinzen-Derr, J.
机构
[1] Div Audiol, Cincinnati, OH 45229 USA
[2] Ctr Biostat & Epidemiol, Cincinnati, OH 45229 USA
[3] Cincinnati Childrens Hosp Med Ctr, Hearing & Deafness Res Ctr, Div Pediat Otolaryngol, Cincinnati, OH 45229 USA
关键词
ventilation tubes; insert earphones; headphones; pediatric audiology;
D O I
10.1016/j.ijporl.2005.11.001
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: To determine the relationship between the type.,of transducer used to perform pure-tone audiometry and the appearance of low-frequency hearing loss at 250 Hz and 500 Hz for patients with ventilation tubes. Methods: Air conduction thresholds' at 250 Hz and 500 Hz were measured using Telephonics TDH-49 supra-aural headphones and EARTONE 3-A insert earphones for patients with normal ears (N = 16) and patients with ventilation tubes (N = 114). Tympanometry was performed on each patient prior to audiometric testing. Audiometric test results obtained in normal ears were compared to results for patients with ventilation tubes. For analysis, the ventilation tube patients were separated into two groups, representative of ventilation tube type. Results: Audiometric results obtained using the two transducer types at 250 Hz and 500 Hz revealed significant differences in threshold for patients with ventilation tubes. Thresholds obtained using insert earphones were generally worse than threshotds obtained using,supra-aural headphones for this group. On average, difference in threshold was 14.15 dB worse with insert earphones at 250 Hz and 9.75 d worse with insert earphones at 500 Hz for patients with Sheehy tubes. Average difference in threshold for patients with Donaldson tubes was 13.93 dB worse with insert earphones at 250 Hz and 8.93 dB worse with insert earphones at 500 Hz. In addition, thresholds were more variable for patients with ventilation tubes than normal ears at 500 Hz. There were no significant differences in threshold for normal ears using both transducers. Conclusions: When performing pure-tone audiometry, choice of transducer can influence the accurate identification of a low-frequency hearing toss in patients with ventilation tubes. Low-frequency thresholds were generally worse using insert-style earphones to test subjects with tubes, resulting in the apparent identification of a hearing loss. However, with supra-aural headphones, no tow-frequency hearing toss existed. There were no significant differences in threshold values using either transducer in normal ears. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1063 / 1067
页数:5
相关论文
共 14 条
[1]  
*ANSI, 1996, SPEC IMM
[2]  
*ANSI, 1996, SPEC AUD
[3]   NORMAL HEARING THRESHOLD LEVELS IN THE LOW-FREQUENCY RANGE DETERMINED BY AN INSERT EARPHONE [J].
ARLINGER, SD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (05) :2411-2414
[4]  
ARLINGER SD, 1998, SCAND AUDIOL, V26, P151
[5]   A CLINICAL COMPARISON OF GRASON STADLER INSERT EARPHONES AND TDH-50P STANDARD EARPHONES [J].
BLACKWELL, KL ;
OYLER, RF ;
SEYFRIED, DN .
EAR AND HEARING, 1991, 12 (05) :361-362
[6]  
BORTON TE, 1989, AUDIOLOGY, V28, P61
[7]   CLINICAL USE OF AN INSERT EARPHONE [J].
CLEMIS, JD ;
BALLAD, WJ ;
KILLION, MC .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1986, 95 (05) :520-524
[8]   Conductive hearing loss associated with pressure equalization tubes [J].
Estrem, SA ;
Batra, PS .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2000, 122 (03) :349-351
[9]   A COMPARISON OF THE VARIABILITY IN THRESHOLDS MEASURED WITH INSERT AND CONVENTIONAL SUPRAAURAL EARPHONES [J].
LINDGREN, F .
SCANDINAVIAN AUDIOLOGY, 1990, 19 (01) :19-23
[10]  
Luks S B, 1989, Entechnology, P21