Auto-calibrated parallel spiral imaging

被引:42
作者
Heberlein, K [1 ]
Hu, XP [1 ]
机构
[1] Emory Univ, Dept Biomed Engn, Biomed Technol Ctr, Atlanta, GA 30322 USA
关键词
spiral; parallel imaging; MRI; GRAPPA; image reconstruction;
D O I
10.1002/mrm.20811
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work describes an auto-calibrated method for parallel imaging with spiral trajectory. The method is a k-space approach where an interpolation kernel, accounting for coil sensitivity factors, is derived from experimental data and used to interpolate the reduced data set in parallel imaging to estimate the missing k-space data. For the case of spiral imaging, this interpolation kernel is defined along radial directions so that missing spiral interleaves can be estimated directly from neighboring interleaves. This kernel is invariant along the radial direction but varies azimuthally. Therefore, the k-space is divided into angular sectors and sector-specific kernels are used. It is demonstrated experimentally that relatively few sectors are sufficient for accurate reconstruction, allowing for efficient implementation. The interpolation kernels can be derived either from a separate calibration scan or self-calibration data available with a dual-density spiral acquisition. The reconstruction method is implemented with two sampling strategies and experimentally demonstrated to be robust. Magn Reson Med 55:619-625, 2006. (c) 2006 Wiley-Liss, Inc.
引用
收藏
页码:619 / 625
页数:7
相关论文
共 34 条
[1]  
ANDERSON E, 1999, LA PACK USERS GUIDE
[2]   Rapid MR imaging by sensitivity profile indexing and deconvolution reconstruction (SPID) [J].
Azhari, H ;
Sodickson, DK ;
Edelman, RR .
MAGNETIC RESONANCE IMAGING, 2003, 21 (06) :575-584
[3]   Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA) [J].
Breuer, FA ;
Kellman, P ;
Griswold, MA ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) :981-985
[4]   Generalized SMASH imaging [J].
Bydder, M ;
Larkman, DJ ;
Hajnal, JV .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :160-170
[5]   IMAGING TIME REDUCTION THROUGH MULTIPLE RECEIVER COIL DATA ACQUISITION AND IMAGE-RECONSTRUCTION [J].
CARLSON, JW ;
MINEMURA, T .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :681-688
[6]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[7]  
Griswold MA, 2000, MAGN RESON MED, V44, P602, DOI 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO
[8]  
2-5
[9]  
Griswold MA, 2003, P INT SOC MAGN RESON, V11, P2349
[10]   BROAD-BAND NUCLEAR MAGNETIC-RESONANCE PULSES WITH TWO-DIMENSIONAL SPATIAL SELECTIVITY [J].
HARDY, CJ ;
CLINE, HE .
JOURNAL OF APPLIED PHYSICS, 1989, 66 (04) :1513-1516