Improving the efficiency of natural draft cooling towers

被引:59
|
作者
Smrekar, J [1 ]
Oman, J [1 ]
Sirok, B [1 ]
机构
[1] Univ Ljubljana, Fac Mech Engn, SI-1000 Ljubljana, Slovenia
关键词
cooling tower; entropy generation; exergy destruction; cooling tower efficiency; heat transfer;
D O I
10.1016/j.enconman.2005.07.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study shows how the efficiency of a natural draft cooling tower can be improved by optimising the heat transfer along the cooling tower (CT) packing using a suitable water distribution across the plane area of the cooling tower. On the basis of cooling air measurements, it is possible to distribute the water in such a way that it approaches the optimal local water/air mass flow ratio and ensures the homogeneity of the heat transfer and a reduction of entropy generation, thus minimising the amount of exergy lost. The velocity and temperature fields of the air flow were measured with the aid of a remote control mobile robot unit that was developed to enable measurements at an arbitrary point above the spray zone over the entire plane area of the cooling tower. The topological structures of the moist air velocity profiles and the temperature profiles above the spray zone were used as input data for calculation of the local entropy generation in the tower. On the basis of the measured boundary conditions, a numerical analysis of the influence of the water distribution across the cooling tower's plane area on entropy generation and exergy destruction in the cooling tower was conducted. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1086 / 1100
页数:15
相关论文
共 50 条
  • [1] Improving the Efficiency of Natural Draft Wet Cooling Towers by Using Smart Metering Systems
    Opris, Ioana
    Costinas, Sorina
    Ionescu, Cristina-Sorana
    Gogoase-Nistoran, Daniela-Elena
    2017 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM) & 2017 INTL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS (ACEMP), 2017, : 134 - 139
  • [2] Novel method for improving the cooling performance of natural draft wet cooling towers
    Chen, Xuehong
    Sun, Fengzhong
    Chen, Youliang
    Gao, Ming
    APPLIED THERMAL ENGINEERING, 2019, 147 : 562 - 570
  • [3] IMPROVING DESIGN OF NATURAL DRAFT COOLING-TOWERS AGAINST BUCKLING FAILURE
    LI, LY
    CROLL, JGA
    CIVIL ENGINEERING SYSTEMS, 1994, 11 (02): : 143 - 157
  • [4] NATURAL DRAFT COOLING TOWERS AND THEIR INFLUENCE ON ENVIRONMENT
    MIKYSKA, L
    BRENNSTOFF-WARME-KRAFT, 1973, 25 (02): : 48 - 51
  • [5] Design of large Natural Draft Cooling Towers
    Kraetzig, Wilfried B.
    Andres, Matthias
    Arntz, Matthias
    Eckstein, Ulrich
    Harte, Reinhard
    Woermann, Ralf
    BAUTECHNIK, 2016, 93 (03) : 151 - 161
  • [6] PERFORMANCE TESTING OF LARGE NATURAL DRAFT COOLING TOWERS
    MORGENWE.FE
    MECHANICAL ENGINEERING, 1969, 91 (05) : 106 - &
  • [7] PERFORMANCE TESTING OF LARGE NATURAL DRAFT COOLING TOWERS
    MORGENWE.FE
    COMBUSTION, 1969, 40 (11): : 16 - &
  • [8] A review of the crosswind effect on the natural draft cooling towers
    Li, Xiaoxiao
    Gurgenci, Hal
    Guan, Zhiqiang
    Wang, Xurong
    Xia, Lin
    APPLIED THERMAL ENGINEERING, 2019, 150 : 250 - 270
  • [9] Natural draft cooling towers with flue gas inlet
    Eisenkrein, Helena
    Kotz-Pollklaesener, Christian
    CONCRETE SOLUTIONS: PROCEEDINGS OF CONCRETE SOLUTIONS, 5TH INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, 2014, : 719 - 726
  • [10] PLUME EFFECTS OF NATURAL DRAFT HYPERBOLIC COOLING TOWERS
    VISBISKY, RF
    BIERMAN, GF
    BITTING, CH
    COMBUSTION, 1970, 42 (04): : 54 - &