A fast and sensitive nanosensor based on MgO nanoparticle room-temperature ionic liquid carbon paste electrode for determination of methyldopa in pharmaceutical and patient human urine samples

被引:53
作者
Vahedi, Javad [1 ]
Karimi-Maleh, Hassan [2 ]
Baghayeri, Mehdi [3 ]
Sanati, Asfaneh L. [2 ]
Khalilzadeh, Mohammad A. [4 ]
Bahrami, Mehrnaz [5 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Phys, Mazandaran, Iran
[2] Grad Univ Adv Technol, Dept Chem, Kerman, Iran
[3] Hakim Sabzevari Univ, Dept Chem, Fac Sci, Sabzevar, Iran
[4] Islamic Azad Univ, Sci & Res Branch, Dept Chem, Mazandaran, Iran
[5] Islamic Azad Univ, Sari Branch, Dept Phys, Sari, Iran
关键词
Methyldopa; Ionic liquid; MgO nanoparticle; Sensor; Modified electrode; NICOTINAMIDE ADENINE-DINUCLEOTIDE; SELECTIVE POTENTIOMETRIC SENSOR; POLYMERIC MEMBRANE ELECTRODES; PYROLYTIC-GRAPHITE ELECTRODE; VOLTAMMETRIC SENSOR; SPECTROPHOTOMETRIC DETERMINATION; ELECTROCHEMICAL SENSOR; GLASSY-CARBON; PVC MATRIX; CHROMATOGRAPHIC DETERMINATION;
D O I
10.1007/s11581-013-0940-z
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, we describe an ionic liquid-MgO nanoparticle modified carbon paste electrode (MgO/NPs/IL/CPE) was used as a simple, fast, and sensitive tool for the investigation of the electrochemical oxidation of methyldopa (MDOP) using voltammetric methods. The MgO/NPs was characterized with different methods such as TEM, SEM, and XRD. The oxidation peak potential of the MDOP at a surface of MgO/NPs/IL/CPE appeared at 450 mV that was about 100 mV lower than the oxidation peak potential at the surface of the traditional carbon paste electrode (CPE) under similar conditions. The electro-oxidation of MDOP occurred in a pH-dependent 2e(-) and 2H(+) process, and the electrode reaction followed a diffusion-controlled pathway. Under optimal conditions at pH 7.0, the anodic peak currents increased linearly with the concentration of MDOP in the range of 0.08-380 mu mol L-1 with a detection limit of 0.03 mu mol L-1 (3 sigma). The proposed sensor was successfully applied to the determination of MDOP in real samples such as drug and urine.
引用
收藏
页码:1907 / 1914
页数:8
相关论文
共 61 条
[1]   Electrochemical behavior of morphine at ZnO/CNT nanocomposite room temperature ionic liquid modified carbon paste electrode and its determination in real samples [J].
Afsharmanesh, Elahe ;
Karimi-Maleh, Hassan ;
Pahlavan, Ali ;
Vahedi, Javad .
JOURNAL OF MOLECULAR LIQUIDS, 2013, 181 :8-13
[2]   Determination of nifedipine using nanostructured electrochemical sensor based on simple synthesis of Ag nanoparticles at the surface of glassy carbon electrode: Application to the analysis of some real samples [J].
Baghayeri, Mehdi ;
Namadchian, Melika ;
Karimi-Maleh, Hassan ;
Beitollahi, Hadi .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 697 :53-59
[3]   A rapid high performance liquid chromatographic determination of methyldopa in human serum with fluorescence detection and alumina extraction: Application to a bioequivalence study [J].
Bahrami, G ;
Kiani, A ;
Mirzaeei, S .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (02) :197-201
[4]   Electrochemical behaviors and determination of carbidopa on carbon nanotubes ionic liquid paste electrode [J].
Beitollah, Hadis ;
Goodarzian, Maryam ;
Khalilzadeh, Mohammad A. ;
Karimi-Maleh, Hassan ;
Hassanzadeh, Marjan ;
Tajbakhsh, Mahgol .
JOURNAL OF MOLECULAR LIQUIDS, 2012, 173 :137-143
[5]   Stopped-flow spectrophotometric determination of dopamine and methyldopa with sodium hydroxide. [J].
Berzas, JJ ;
Lemus, JM ;
Buitrago, P .
ANALYTICAL LETTERS, 1997, 30 (06) :1109-1120
[6]   Application of ZnO/CNTs Nanocomposite Ionic Liquid Paste Electrode as a Sensitive Voltammetric Sensor for Determination of Ascorbic Acid in Food Samples [J].
Bijad, Majede ;
Karimi-Maleh, Hassan ;
Khalilzadeh, Mohammad A. .
FOOD ANALYTICAL METHODS, 2013, 6 (06) :1639-1647
[7]  
Buduwy SS, 1996, ELECTROANAL, V8, P1060
[8]   Simultaneous kinetic-spectrophotometric determination of carbidopa, levodopa and methyldopa in the presence of citrate with the aid of multivariate calibration and artificial neural networks [J].
Chamsaz, M. ;
Safavi, A. ;
Fadaee, J. .
ANALYTICA CHIMICA ACTA, 2007, 603 (02) :140-146
[9]   Direct high-performance liquid chromatographic determination of the enantiomeric purity of levodopa and methyldopa:: comparison with pharmacopoeial polarimetric methods [J].
Dolezalová, M ;
Tkaczyková, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (3-4) :555-567
[10]   Highly sensitive voltammetric sensor based on catechol-derivative-multiwall carbon nanotubes for the catalytic determination of captopril in patient human urine samples [J].
Ensafi, A. A. ;
Karimi-Maleh, H. ;
Mallakpour, S. ;
Rezaei, B. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 87 (02) :480-488