Cross-validation in cryo-EM-based structural modeling

被引:40
|
作者
Falkner, Benjamin [1 ]
Schroeder, Gunnar F. [1 ,2 ]
机构
[1] Forschungszentrum Julich, Inst Complex Syst ICS 6, D-52425 Julich, Germany
[2] Univ Dusseldorf, Dept Phys, D-40225 Dusseldorf, Germany
关键词
flexible fitting; real-space structure refinement; ELECTRON-DENSITY MAPS; PROTEIN STRUCTURES; ATOMIC STRUCTURES; RESOLUTION; REFINEMENT; CRYSTALLOGRAPHY; BIAS;
D O I
10.1073/pnas.1119041110
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Single-particle cryo-EM is a powerful approach to determine the structure of large macromolecules and assemblies thereof in many cases at subnanometer resolution. It has become popular to refine or flexibly fit atomic models into density maps derived from cryo-EM experiments. These density maps are typically significantly lower in resolution than electron density maps obtained from X-ray diffraction experiments, such that the number of parameters that need to be determined is much larger than the number of experimental observables. Overfitting and misinterpretation of the density, thus, become a serious problem. For diffraction data, a cross-validation approach was introduced almost 20 y ago; however, no such approach has been described yet for structure refinement against cryo-EM density maps, although the overfitting problem is, because of the lower resolution, significantly larger. We present a cross-validation approach for real-space refinement against cryo-EM density maps in analogy to cross-validation typically used in crystallography. Our approach is able to detect overfitting and allows for optimizing the choice of restraints used in the refinement. The approach is shown on three protein structures with simulated data and experimental data of the rotavirus double-layer particle. Because cross-validation requires splitting the dataset into at least two independent sets, we further present an approach to quantify correlations between the structure factor sets. This analysis is also helpful for other cross-validation applications, such as refinements against diffraction data or 3D reconstructions of cryo-EM density maps.
引用
收藏
页码:8930 / 8935
页数:6
相关论文
共 50 条
  • [41] Improving cryo-EM structure validation
    Alexis Rohou
    Nature Methods, 2021, 18 : 130 - 131
  • [42] Improving cryo-EM structure validation
    Rohou, Alexis
    NATURE METHODS, 2021, 18 (02) : 130 - 131
  • [43] Single-particle Cryo-EM of calcium release channels: structural validation
    Ludtke, Steven J.
    Serysheva, Irina I.
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2013, 23 (05) : 755 - 762
  • [45] Cross-validation and permutations in MVPA: Validity of permutation strategies and power of cross-validation schemes
    Valente, Giancarlo
    Castellanos, Agustin Lage
    Hausfeld, Lars
    De Martino, Federico
    Formisano, Elia
    NEUROIMAGE, 2021, 238
  • [46] Dynamic weighting ensemble classifiers based on cross-validation
    Zhu Yu-Quan
    Ou Ji-Shun
    Chen Geng
    Yu Hai-Ping
    NEURAL COMPUTING & APPLICATIONS, 2011, 20 (03): : 309 - 317
  • [47] Dynamic weighting ensemble classifiers based on cross-validation
    Zhu Yu-Quan
    Ou Ji-Shun
    Chen Geng
    Yu Hai-Ping
    Neural Computing and Applications, 2011, 20 : 309 - 317
  • [49] A resolution criterion for electron tomography based on cross-validation
    Cardone, G
    Grünewald, K
    Steven, AC
    JOURNAL OF STRUCTURAL BIOLOGY, 2005, 151 (02) : 117 - 129
  • [50] Fast Cross-Validation for Kernel-Based Algorithms
    Liu, Yong
    Liao, Shizhong
    Jiang, Shali
    Ding, Lizhong
    Lin, Hailun
    Wang, Weiping
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2020, 42 (05) : 1083 - 1096