Pure-Tone Masking Patterns for Monopolar and Phantom Electrical Stimulation in Cochlear Implants

被引:1
|
作者
Saoji, Aniket A. [1 ,2 ]
Koka, Kanthaiah [1 ,2 ]
Litvak, Leonid M. [1 ,2 ]
Finley, Charles C. [1 ,2 ]
机构
[1] Adv Bion LLC, Res & Technol, 28515 Westinghouse Pl, Valencia, CA 91355 USA
[2] Adv Bion, Valencia, CA USA
来源
EAR AND HEARING | 2018年 / 39卷 / 01期
关键词
ACOUSTIC STIMULATION; AUDITORY-SYSTEM; HEARING; USERS; EAR;
D O I
10.1097/AUD.0000000000000471
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: Monopolar stimulation of the most apical electrode produces the lowest pitch sensation in cochlear implants clinically. A phantom electrode that uses out-of-phase electrical stimulation between the most apical and the neighboring basal electrode can produce a lower pitch sensation than that associated with the most apical electrode. However, because of the absence of contacts beyond the apical tip of the array, the ability to assess the spread of electrical excitation associated with phantom stimulation is limited in the typical cochlear implant subject with no residual hearing. In the present study, the spread of electrical excitation associated with monopolar and phantom stimulation of the most apical electrode was assessed using electrical masking of acoustic thresholds in cochlear implant subjects with residual, low-frequency, acoustic hearing. Design: Eight subjects with an Advanced Bionics cochlear implant and residual hearing in the implanted ear participated in this study (nine ears in total). Unmasked and masked thresholds for acoustic pure tones were measured at 125, 250, 500, 750, 1000, and 2000 Hz in the presence of monopolar and phantom electrode stimulation presented at the apical-most end of the array. The current compensation for phantom electrode stimulation was fixed at 50%. The two electrical maskers were loudness balanced. Differences between the unmasked and masked acoustic thresholds can be attributed to (1) the electrical stimulus-induced interference in the transduction/conduction of the acoustic signal through cochlear periphery and the auditory nerve and/or (2) masking at the level of the central auditory system. Results: The results show a significant elevation in pure-tone thresholds in the presence of the monopolar and phantom electrical maskers. The unmasked thresholds were subtracted from the masked thresholds to derive masking patterns as a function of the acoustic probe frequency. The masking patterns show that phantom stimulation was able to produce more masking than that associated with the monopolar stimulation of the most apical electrode. Conclusion: These results suggest that for some cochlear implant subjects, phantom electrode stimulation can shift the neural stimulation pattern more apically in the cochlea, which is consistent with reports that phantom electrode stimulation produces lower pitch sensations than those associated with monopolar stimulation of the most apical electrode alone.
引用
收藏
页码:124 / 130
页数:7
相关论文
共 50 条
  • [1] Masking patterns for monopolar and phantom electrode stimulation in cochlear implants
    Saoji, Aniket A.
    Landsberger, David M.
    Padilla, Monica
    Litvak, Leonid M.
    HEARING RESEARCH, 2013, 298 : 109 - 116
  • [2] MASKING PATTERNS OF PURE-TONE MASKERS
    SCHONE, P
    ACUSTICA, 1979, 43 (03): : 197 - 204
  • [3] PURE-TONE MASKING PATTERNS IN NONSIMULTANEOUS MASKING CONDITIONS
    MIYAZAKI, K
    SASAKI, T
    JAPANESE PSYCHOLOGICAL RESEARCH, 1984, 26 (02) : 110 - 119
  • [4] PURE-TONE MASKING IN NORMAL AND COCHLEAR IMPAIRED EARS
    RICHARDS, AM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1972, 52 (01): : 184 - &
  • [5] PURE-TONE MASKING IN COCHLEAR NERVE OF GOLDEN HAMSTER
    FINCK, A
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1965, 37 (06): : 1200 - &
  • [6] PURE-TONE MASKING
    SMALL, AM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1959, 31 (12): : 1619 - 1625
  • [7] PURE-TONE MASKING OF TINNITUS
    FORMBY, C
    GJERDINGEN, DB
    AUDIOLOGY, 1980, 19 (06): : 519 - 535
  • [8] MASKING IN PURE-TONE AUDIOMETRY
    DENES, P
    NAUNTON, RF
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1952, 45 (11): : 790 - 794
  • [9] DEPENDENCE OF MASKING PATTERNS OF PURE-TONE MASKERS ON THE MASKER FREQUENCY
    SONNTAG, B
    ACUSTICA, 1983, 52 (02): : 95 - 97
  • [10] COMBINATION OF NOISE AND PURE-TONE MASKING
    GREEN, DM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1962, 34 (05): : 745 - &