Effect of electrolyte pH on CIEF with narrow pH range ampholytes

被引:11
作者
Pager, Csilla [1 ]
Vargova, Andrea [2 ]
Takacsi-Nagy, Anna [1 ]
Doernyei, Agnes [1 ]
Kilar, Ferenc [1 ,2 ]
机构
[1] Univ Pecs, Fac Med, Inst Bioanal, H-7624 Pecs, Hungary
[2] Univ Pecs, Fac Sci, Dept Analyt & Environm Chem, H-7624 Pecs, Hungary
关键词
Capillary isoelectric focusing; Carrier ampholytes; pH of electrolyte; pI markers; Sequential injection; ELECTROOSMOTIC ZONE DISPLACEMENT; CARRIER AMPHOLYTES; FOCUSING PROPERTIES; MASS-DISTRIBUTION; ELECTROPHORETIC MOBILIZATION; IEF; POLYDISPERSITY; INTERVALS; PROTEINS; MS;
D O I
10.1002/elps.201200175
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
CIEF of components following sequential injection of ampholytes and the sample zone offers unique advantages for analysis. The most important one of these is the efficient separation of amphoteric compounds having pIs outside the pH range of the ampholytes applied, but the resolution of the components can be increased by an adequate setup in the injection protocol. In this study, the effect of the pH of the anolyte and catholyte on the selectivity and speed of the isoelectric focusing was investigated. Changes in the pH values significantly influenced the resolution and the length of the pH gradient, while changes in the charge state of components were also observed. Three ampholyte solutions (from different suppliers) covering only two pH units were used for the analyses of substituted nitrophenol dyes in uncoated capillary. With appropriate setup, the components, with pIs not covered by the ampholyte pH range, migrated in charged state outside the pH gradient. This phenomenon is preferable for coupling isoelectric focusing to MS detection, by evading the undesirable ion suppression effect of ampholytes.
引用
收藏
页码:3269 / 3275
页数:7
相关论文
共 28 条
[1]   BEHAVIOR OF SUBSTITUTED AMINOMETHYLPHENOL DYES IN CAPILLARY ISOELECTRIC-FOCUSING WITH ELECTROOSMOTIC ZONE DISPLACEMENT [J].
CASLAVSKA, J ;
MOLTENI, S ;
CHMELIK, J ;
SLAIS, K ;
MATULIK, F ;
THORMANN, W .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (02) :549-559
[2]   Capillary electrophoretic separations of proteins using carrier ampholytes [J].
Chartogne, A ;
Reeuwijk, B ;
Hofte, B ;
van der Heijden, R ;
Tjaden, UR ;
van der Greef, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 959 (1-2) :289-298
[3]   Quantitation of glycated hemoglobins in human adult blood by capillary isoelectric focusing [J].
Conti, M ;
Gelfi, C ;
Bosisio, AB ;
Righetti, PG .
ELECTROPHORESIS, 1996, 17 (10) :1590-1596
[4]   Multistage isoelectric focusing in a polymeric microfluidic chip [J].
Cui, HC ;
Horiuchi, K ;
Dutta, P ;
Ivory, CF .
ANALYTICAL CHEMISTRY, 2005, 77 (24) :7878-7886
[5]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[6]   THEORETICAL AND EXPERIMENTAL-STUDY OF HIGH-PERFORMANCE ELECTROPHORETIC MOBILIZATION OF ISOELECTRICALLY FOCUSED PROTEIN ZONES [J].
HJERTEN, S ;
LIAO, JL ;
YAO, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :127-138
[7]  
Hjerten S., 1986, ELECTROPHORESIS, P451
[8]   Adaptation of capillary isoelectric focusing to microchannels on a glass chip [J].
Hofmann, O ;
Che, DP ;
Cruickshank, KA ;
Müller, UR .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :678-686
[9]   New set-up for capillary isoelectric focusing in uncoated capillaries [J].
Kilár, F ;
Végvári, A ;
Mód, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 813 (02) :349-360
[10]   On-line capillary isoelectric focusing-mass spectrometry for quantitative analysis of peptides and proteins [J].
Kuroda, Y ;
Yukinaga, H ;
Kitano, M ;
Noguchi, T ;
Nemati, M ;
Shibukawa, A ;
Nakagawa, T ;
Matsuzaki, K .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (03) :423-428