Intensity matters: Therapist-dependent dose of spinal transcutaneous electrical nerve stimulation

被引:17
作者
Serrano-Munoz, Diego [1 ]
Gomez-Soriano, Julio [2 ]
Bravo-Esteban, Elisabeth [2 ]
Vazquez-Farinas, Maria [3 ]
Taylor, Julian [1 ,4 ,5 ]
Avendano-Coy, Juan [2 ]
机构
[1] Hosp Nacl Paraplej, Sensorimotor Funct Grp, Toledo, Spain
[2] Castilla Mancha Univ, Nursing & Physiotherapy Sch, Toledo Physiotherapy Res Grp GIFTO, Toledo, Spain
[3] Hosp Nacl Paraplej, SESCAM, Toledo, Spain
[4] NHS, Buckinghamshire Healthcare Trust, Natl Spinal Injuries Ctr, Stoke Mandeville Spinal Res, Aylesbury, Bucks, England
[5] Univ Oxford, Harris Manchester Coll, Oxford, England
关键词
H-REFLEX; PARAMETER MANIPULATION; HEMIPARETIC SUBJECTS; EXPERIMENTAL PAIN; TENS; SPASTICITY; EXCITABILITY; THRESHOLDS; FREQUENCY; PRESSURE;
D O I
10.1371/journal.pone.0189734
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The intensity used during transcutaneous electrical nerve stimulation (TENS) in both, clinical practice and research studies, is often based on subjective commands such as strong but comfortable sensation. There is no consensus regarding the effectiveness dose of TENS. The objective was to determine the difference in the effect of spinal TENS on soleus H-reflex modulation when applied by two therapists instructed to apply the stimulation at a strong but comfortable intensity. Twenty healthy volunteers divided into two groups: Therapist 1 (n = 10) and Therapist 2 (n = 10). Both therapist applied spinal TENS and sham stimulation at the T1012 spinal level for 40min in random order to each subject, at an intensity designed to produce a strong but comfortable sensation. To avoid habituation, the intensity was adjusted every 2min. Soleus H-reflex was recorded before, during, and 10min after TENS by an observer blinded to the stimulus applied. Despite the instruction to apply TENS at a strong comfortable level, a significant difference in current density was identified: Therapist 1 (0.67mA/cm(2), SD 0.54) applied more than Therapist 2 (0.53mA/cm(2), SD 0.57; p<0.001) at the onset of the intervention. Maximal peak-to-peak H-reflex amplitude was inhibited significantly more 10min following TENS applied by Therapist 1 (-0.15mV, SD 0.16) compared with Therapist 2 (0.04mV, SD 0.16; p = 0.03). Furthermore, current density significantly correlated with the inhibitory effect on peak-to-peak Soleus H-reflex amplitude 10 min after stimulation (Rho = -0.38; p = 0.04). TENS intensity dosage by the therapist based on the subjective perception of the participants alone is unreliable and requires objective standardization. In addition, higher current density TENS produced greater inhibition of the Soleus H-reflex
引用
收藏
页数:15
相关论文
共 41 条
[11]   Dose-specific Effects of Transcutaneous Electrical Nerve Stimulation (TENS) on Experimental Pain A Systematic Review [J].
Claydon, Leica S. ;
Chesterton, Linda S. ;
Barlas, Panos ;
Sim, Julius .
CLINICAL JOURNAL OF PAIN, 2011, 27 (07) :635-647
[12]  
Cramp FL, 2000, ARCH PHYS MED REHAB, V81, P324, DOI 10.1053/apmr.2000.0810324
[13]  
CRONE C, 1990, EXP BRAIN RES, V81, P35
[14]   The effects of unilateral transcutaneous electrical nerve stimulation of the median nerve on bilateral somatosensory thresholds [J].
Dean, Jaqueline ;
Bowsher, David ;
Johnson, Mark I. .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2006, 26 (05) :314-318
[15]   CAN TRIALS OF PHYSICAL TREATMENTS BE BLINDED - THE EXAMPLE OF TRANSCUTANEOUS ELECTRICAL NERVE-STIMULATION FOR CHRONIC PAIN [J].
DEYO, RA ;
WALSH, NE ;
SCHOENFELD, LS ;
RAMAMURTHY, S .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1990, 69 (01) :6-10
[16]   Peripheral nerve stimulation inhibits nociceptive processing: An electrophysiological study in healthy volunteers [J].
Ellrich, J ;
Lamp, S .
NEUROMODULATION, 2005, 8 (04) :225-232
[17]  
Fernandez-Tenorio E, 2016, NEUROLOGIA
[18]   Evaluation and quantification of spasticity: a review of the clinical, biomechanical and neurophysiological methods [J].
Gomez-Soriano, Julio ;
Cano-de-la-Cuerda, Roberto ;
Munoz-Hellin, Elena ;
Ortiz-Gutierrez, Rosa ;
Taylor, Julian S. .
REVISTA DE NEUROLOGIA, 2012, 55 (04) :217-226
[19]   ABSENCE OF CONSISTENT EFFECTS OF REPETITIVE TRANSCUTANEOUS ELECTRICAL-STIMULATION ON SOLEUS H-REFLEX IN NORMAL SUBJECTS [J].
GOULET, C ;
ARSENAULT, AB ;
LEVIN, MF ;
BOURBONNAIS, D ;
LEPAGE, Y .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1994, 75 (10) :1132-1136
[20]   The effect of transcutaneous electrical stimulation on spinal motor neuron excitability in people without known neuromuscular diseases: The roles of stimulus intensity and location [J].
Hardy, SG ;
Spalding, TB ;
Liu, H ;
Nick, TG ;
Pearson, RH ;
Hayes, AV ;
Stokic, DS .
PHYSICAL THERAPY, 2002, 82 (04) :354-363