Synthesis, characterization, and bioactivity investigation of biomimetic biodegradable PLA scaffold fabricated by fused filament fabrication process

被引:84
作者
Singh, Daljeet [1 ]
Babbar, Atul [1 ]
Jain, Vivek [1 ]
Gupta, Dheeraj [1 ]
Saxena, Sanjai [2 ]
Dwibedi, Vagish [2 ]
机构
[1] Thapar Inst Engn & Technol, Dept Mech Engn, Patiala 147003, Punjab, India
[2] Thapar Inst Engn & Technol, Dept Biotechnol, Patiala, Punjab, India
关键词
Polylactic acid; Additive manufacturing; Simulated body fluid; Scaffolds; Degradation; MECHANICAL-PROPERTIES; ELECTROSPUN SCAFFOLDS; TISSUE; COMPOSITE; DEGRADATION; PARAMETERS; DESIGN;
D O I
10.1007/s40430-019-1625-y
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Nowadays polylactic acid (PLA) is widely used in orthopedics surgeries as implants material due to well mechanical characterization and biomedical properties. But the PLA implants suffer from slow degradation rate when it is used in real-life scenario. In the present research work, the PLA specimens using additive manufacturing technique are fabricated and further assessed for mechanical characterization and its degradation behavior with different parameters. The change in weight of scaffolds was measured using digital weight measure, and pH value was measured using pH meter. Morphology and elemental composition of PLA scaffolds were characterized by SEM and EDS, respectively, while compressive strength is measured by the universal testing machine. Apatite formation and biocompatible nature of fabricated scaffolds were analyzed by in vitro simulated body fluid study. The outcomes of characterization exposed that scaffold with 60% infill percentage had maximum porosity, which is beneficial for the apatite formation and osseointegration. The average change in compressive strength was measured as 49.79MPa after 14days and 46.11MPa after 28days, whereas the average change in pH value was measured as 5.67 and 5.27 after 14 and 28days of incubation period, respectively. The degradation rate of specimen 3 was 27.92% less than that of specimen 1, 35.69% less than that of specimen 5, and 87.98% more than that of specimen 9. This study concludes the positive effect of process parameters on degradation rate and biocompatible behavior of PLA implants.
引用
收藏
页数:13
相关论文
共 47 条
[1]   A study on mechanical behavior and wear performance of a metal-metal Co-30Cr biomedical alloy with different molybdenum addition and optimized using Taguchi experimental design [J].
Aherwar, Amit ;
Singh, Amit ;
Patnaik, Amar .
JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2018, 40 (04)
[2]   The potential to improve cell infiltration in composite fiber-aligned electrospun scaffolds by the selective removal of sacrificial fibers [J].
Baker, Brendon M. ;
Gee, Albert O. ;
Metter, Robert B. ;
Nathan, Ashwin S. ;
Marklein, Ross A. ;
Burdick, Jason A. ;
Mauck, Robert L. .
BIOMATERIALS, 2008, 29 (15) :2348-2358
[3]  
Basavaraj C. K., 2016, IOP C SERIES MAT SCI
[4]   Additive manufacturing of PLA structures using fused deposition modelling: Effect of process parameters on mechanical properties and their optimal selection [J].
Chacon, J. M. ;
Caminero, M. A. ;
Garcia-Plaza, E. ;
Nunez, P. J. .
MATERIALS & DESIGN, 2017, 124 :143-157
[5]  
Chang HI, 2011, REGENERATIVE MEDICINE AND TISSUE ENGINEERING - CELLS AND BIOMATERIALS, P569
[6]   Hyaluronic acid based scaffolds for tissue engineering-A review [J].
Collins, Maurice N. ;
Birkinshaw, Colin .
CARBOHYDRATE POLYMERS, 2013, 92 (02) :1262-1279
[7]   Chitosan-based biomaterials for tissue engineering [J].
Croisier, Florence ;
Jerome, Christine .
EUROPEAN POLYMER JOURNAL, 2013, 49 (04) :780-792
[8]  
De Ciurana J, 2013, PROCEDIA CIRP
[9]   3D Printing of Scaffolds for Tissue Regeneration Applications [J].
Do, Anh-Vu ;
Khorsand, Behnoush ;
Geary, Sean M. ;
Salem, Aliasger K. .
ADVANCED HEALTHCARE MATERIALS, 2015, 4 (12) :1742-1762
[10]   Physical and mechanical properties of PLA, and their functions in widespread applications - A comprehensive review [J].
Farah, Shady ;
Anderson, Daniel G. ;
Langer, Robert .