Interface phenomena in stator winding insulation -: Challenges in design, diagnosis, and service experience

被引:39
作者
Kaufhold, M [1 ]
Schäfer, K [1 ]
Bauer, K [1 ]
Bethge, A [1 ]
Risse, J [1 ]
机构
[1] Siemens AG, A&D Large Drives, Berlin, Germany
关键词
thermo-mechanical stress; electrical stress; microscopic interfaces; macroscopic interfaces;
D O I
10.1109/57.995396
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The service life of insulation systems for high-voltage, traction and low-voltage motors is determined by phenomena at their internal and external macroscopic and microscopic interfaces. The properties of these interfaces are matched specifically to the stresses during testing and in operation. To date, advances have been made in new materials, manufacturing technology, and diagnostic tools for insulation systems for machines. Models of the behavior of different interfaces verify the long-term performance under extreme service conditions.
引用
收藏
页码:27 / 36
页数:10
相关论文
共 17 条
[1]  
BAUER K, 1998, P INSUCON 98 HARR MA
[2]   Preliminary evaluation of CR Kapton®-backed mica paper tape for high voltage, coil groundwall insulation using vacuum pressure impregnation [J].
Emery, FT .
IEEE ELECTRICAL INSULATION MAGAZINE, 1998, 14 (05) :12-15
[3]   Problems with modern air-cooled generator stator winding insulation [J].
Griffith, G ;
Tucker, S ;
Milsom, J ;
Stone, G .
IEEE ELECTRICAL INSULATION MAGAZINE, 2000, 16 (06) :6-10
[4]  
*IEC, 6003418 IEC
[5]   Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled inverters [J].
Kaufhold, M ;
Borner, G ;
Eberhardt, M ;
Speck, J .
IEEE ELECTRICAL INSULATION MAGAZINE, 1996, 12 (05) :9-16
[6]   Electrical stress and failure mechanism of the winding insulation in PWM-inverter-fed low-voltage induction motors [J].
Kaufhold, M ;
Auinger, H ;
Berth, M ;
Speck, J ;
Eberhardt, M .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (02) :396-402
[7]  
KAUFHOLD M, 1995, VDI VERLAG 21, V172
[8]  
KAUFHOLD M, 1999, BAND HIGH VOLT K GER
[9]  
LANGER J, 1992, 40 ETG
[10]  
Meyer H., 1962, ISOLIERUNG GROSSER E