Assessment of knee cartilage in cadavers with dual-detector spiral CT arthrography and MR imaging

被引:79
作者
Vande Berg, BC
Lecouvet, FE
Poilvache, P
Jamart, J
Materne, R
Lengele, B
Maldague, B
Malghem, J
机构
[1] Catholic Univ Louvain, Clin Univ St Luc, Dept Radiol, B-1200 Brussels, Belgium
[2] Catholic Univ Louvain, Clin Univ St Luc, Dept Orthopaed Surg, B-1200 Brussels, Belgium
[3] Catholic Univ Louvain, Clin Univ St Luc, Dept Anat, B-1200 Brussels, Belgium
关键词
knee; CT; ligaments; menisci; and cartilage; MR; arthritis;
D O I
10.1148/radiol.2222010597
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess dual-detector spiral CT arthrography in the evaluation of the entire knee cartilage obtained from cadavers. MATERIALS AND METHODS: Two independent observers characterized articular cartilage in 12 cadaver knees in which MR imaging and dual-detector spiral CT arthrography were performed and compared their findings to those found during macroscopic assessment. The sensitivity and specificity of MR imaging and spiral CT arthrography for detecting grade 2A or higher and grade 2B or higher cartilage lesions, the Spearman correlation coefficient between arthrographic and macroscopic grading, and kappa statistics for assessing interobserver reproducibility were determined. RESULTS: At spiral CT arthrography, sensitivities and specificities ranged between 80% and 88% for the detection of grade 2A or higher cartilage lesions and ranged between 85% and 94% for the detection of grade 2B or higher cartilage lesions. At MR imaging, sensitivities and specificities ranged between 78% and 86% and between 76% and 91% for the detection of grade 2A or higher and grade 2B or higher cartilage lesions, respectively. Spearman correlation coefficients between spiral CT arthrography or MR imaging and macroscopic grading of articular surfaces were 0.797 and 0.702, respectively. CONCLUSION: Dual-detector spiral CT arthrography of the knee is a valuable method for the assessment of open cartilage lesions of the entire knee.
引用
收藏
页码:430 / 436
页数:7
相关论文
共 38 条
[1]   Evaluation of patellar cartilage in cadavers with a low-field-strength extremity-only magnet: Comparison of MR imaging sequences, with macroscopic findings as the standard [J].
Ahn, JM ;
Kwak, SM ;
Kang, HS ;
Muhle, C ;
Pedowitz, PA ;
Frank, LR ;
Trudell, D ;
Haghighi, P ;
Resnick, D .
RADIOLOGY, 1998, 208 (01) :57-62
[2]   Multidetector-array CT: Once again, technology creates new opportunities [J].
Berland, LL ;
Smith, JK .
RADIOLOGY, 1998, 209 (02) :327-329
[3]  
BERLAND LL, 1987, PRACTICAL CT TECHNOL, P56
[4]   THE VALUE OF COMPUTED-TOMOGRAPHY SCANNING IN CHONDROMALACIA PATELLAE [J].
BOVEN, F ;
BELLEMANS, MA ;
GEURTS, J ;
DEBOECK, H ;
POTVLIEGE, R .
SKELETAL RADIOLOGY, 1982, 8 (03) :183-185
[5]   Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients [J].
Bredella, MA ;
Tirman, PFJ ;
Peterfy, CG ;
Zarlingo, M ;
Feller, JF ;
Bost, FW ;
Belzer, JP ;
Wischer, TK ;
Genant, HK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1073-1080
[6]   HELICAL CT - PRINCIPLES AND TECHNICAL CONSIDERATIONS [J].
BRINK, JA ;
HEIKEN, JP ;
WANG, G ;
MCENERY, KW ;
SCHLUETER, FJ ;
VANNIER, MW .
RADIOGRAPHICS, 1994, 14 (04) :887-893
[7]  
BRINK JA, 1995, HELICAL SPIRAL CT PR, P1
[8]   Short echo time projection reconstruction MR imaging of cartilage: Comparison with fat-suppressed spoiled GRASS and magnetization transfer contrast MR imaging [J].
Brossmann, J ;
Frank, LR ;
Pauly, JM ;
Boutin, RD ;
Pedowitz, RA ;
Haghighi, P ;
Resnick, D .
RADIOLOGY, 1997, 203 (02) :501-507
[9]   KNEE HYALINE CARTILAGE EVALUATED WITH MR IMAGING - A CADAVERIC STUDY INVOLVING MULTIPLE IMAGING SEQUENCES AND INTRAARTICULAR INJECTION OF GADOLINIUM AND SALINE SOLUTION [J].
CHANDNANI, VP ;
HO, C ;
CHU, P ;
TRUDELL, D ;
RESNICK, D .
RADIOLOGY, 1991, 178 (02) :557-561
[10]   COMPARISON OF CORRELATED CORRELATIONS [J].
COHEN, A .
STATISTICS IN MEDICINE, 1989, 8 (12) :1485-1495