Performance of methods of occlusal caries detection in permanent teeth under clinical and laboratory conditions

被引:56
作者
Reis, A
Mendes, FM
Angnes, V
Angnes, G
Grande, RHM
Loguercio, AD
机构
[1] Univ Oeste Santa Catarina, Sch Dent, Dept Dent Mat & Operat Dent, Joacaba, Brazil
[2] Univ Sao Paulo, Sch Dent, Dept Pediat Dent, Sao Paulo, Brazil
[3] Univ Sao Paulo, Sch Dent, Dept Dent Mat, Sao Paulo, Brazil
关键词
diagnosis; visual inspection; laser fluorescence; occlusal dental caries; permanent teeth;
D O I
10.1016/j.jdent.2005.04.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare performance of visual inspection and Laser fluorescence methods to detect occlusal caries lesions under clinical and laboratory conditions in permanent teeth. Methods: One hundred and ten sites in 57 third molars scheduled for extraction were examined with visual inspection and Laser fluorescence (DIAGNOdent) device by two trained examiners. After the extraction, teeth were re-examined. Then, teeth were sectioned to perform histological validation. Best cut-off points were calculated with ROC analysis, and sensitivity, specificity and accuracy were calculated at D2 and D3 thresholds. Comparisons between the methods and conditions of examination were performed using McNemar test. Inter-examiner agreement in the same conditions and agreement between the methods performed in vivo and in vitro conditions were assessed by Kappa test. Laser fluorescence values obtained in two conditions were compared with Wilcoxon test. Results: No difference was observed with visual inspection in both conditions. Laser fluorescence performed in vitro presented higher specificity and accuracy at D3 threshold. Visual inspection showed higher reproducibility. After adjustment of cutoff points for laser fluorescence method, there was no difference between the evaluated parameters. Conclusion: Only slightly differences were observed between the examinations performed under clinical and laboratory conditions in the detection of occlusal caries lesions in permanent teeth. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 33 条
[1]   Reliability and validity issues of laser fluorescence measurements in occlusal caries diagnosis [J].
Alwas-Danowska, HA ;
Plasschaert, AJM ;
Suliborski, S ;
Verdonschot, EH .
JOURNAL OF DENTISTRY, 2002, 30 (04) :129-134
[2]  
[Anonymous], 2002, J DENT CHILD
[3]   A systematic review of the performance of a laser fluorescence device for detecting caries [J].
Bader, JD ;
Shugars, DA .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (10) :1413-1426
[4]   A systematic review of the performance of methods for identifying carious lesions [J].
Bader, JD ;
Shugars, DA ;
Bonito, AJ .
JOURNAL OF PUBLIC HEALTH DENTISTRY, 2002, 62 (04) :201-213
[5]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[6]   An in vitro comparison of a combined FOTI/visual examination of occlusal caries with other caries diagnostic methods and the effect of stain on their diagnostic performance [J].
Côrtes, DF ;
Ellwood, RP ;
Ekstrand, KR .
CARIES RESEARCH, 2003, 37 (01) :8-16
[7]   CONCURRENT VALIDITY OF AN EPIDEMIOLOGICAL DIAGNOSTIC SYSTEM FOR CARIES WITH HISTOLOGICAL APPEARANCE OF EXTRACTED TEETH AS VALIDATING CRITERION [J].
DOWNER, MC .
CARIES RESEARCH, 1975, 9 (03) :231-246
[8]  
Ekstrand K R, 2004, J Dent Res, V83 Spec No C, pC67
[9]   Detection, diagnosing, monitoring and logical treatment of occlusal caries in relation to lesion activity and severity: An in vivo examination with histological validation [J].
Ekstrand, KR ;
Ricketts, DNJ ;
Kidd, EAM ;
Qvist, V ;
Schou, S .
CARIES RESEARCH, 1998, 32 (04) :247-254
[10]   Reproducibility and accuracy of three methods for assessment of demineralization depth on the occlusal surface: An in vitro examination [J].
Ekstrand, KR ;
Ricketts, DNJ ;
Kidd, EAM .
CARIES RESEARCH, 1997, 31 (03) :224-231