Effect of Structural Design of Silver/Silver Chloride Electrodes on Stability and Response Time and the Implications for Improved Accuracy in pH Measurement

被引:20
作者
Brewer, Paul J. [1 ]
Brown, Richard J. C. [1 ]
机构
[1] Natl Phys Lab, Analyt Sci Team, Teddington TW11 0LW, Middx, England
关键词
pH; Harned cell; Ag/AgCl chloride electrode; stability; primary methods;
D O I
10.3390/s90100118
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The response time of thermal electrolytic Ag/AgCl reference electrodes is defined by the porous structure that limits the rate at which traces of any previous solution are diluted by any new solution environment. The electrode stabilisation time when transferred from one electrolyte to another has been shown to change when different structural designs to the conventional sphere of Ag/AgCl are used. Electrodes fabricated with cylindrical architectures of Ag/AgCl have shown improved stability and reach equilibrium faster than spherical electrodes. This work has positive implications for the accuracy and throughput of primary pH measurements made using the Harned cell.
引用
收藏
页码:118 / 130
页数:13
相关论文
共 19 条
[1]  
BATES RG, 1973, DETERMINATION PH
[2]  
*BRIT STAND I, 1979, 25861979 BS BRIT STA
[3]   The microporous structure of silver/silver chloride electrodes and the implications for Harned cell operation [J].
Brown, RJC ;
Milton, MJT .
ACCREDITATION AND QUALITY ASSURANCE, 2005, 10 (07) :352-355
[4]   Observation of a combined dilution and salting effect in buffers under conditions of high dilution and high ionic strength [J].
Brown, RJC ;
Milton, MJT .
ACCREDITATION AND QUALITY ASSURANCE, 2003, 8 (11) :505-510
[5]   Measurement of pH. Definition, standards, and procedures [J].
Buck, RP ;
Rondinini, S ;
Covington, AK ;
Baucke, FGK ;
Brett, CMA ;
Camoes, MF ;
Milton, MJT ;
Mussini, T ;
Naumann, R ;
Pratt, KW ;
Spitzer, P ;
Wilson, GS .
PURE AND APPLIED CHEMISTRY, 2002, 74 (11) :2169-2200
[6]   pH electrode performance under automated management conditions [J].
Comer, JEA ;
Hibbert, C .
JOURNAL OF AUTOMATIC CHEMISTRY, 1997, 19 (06) :213-224
[7]  
COVINGTON AK, 1969, NBS SPEC PUBL, V314, P107
[8]  
Galster H., 1991, Ph measurement, V1st
[9]   Potentiometric method for the accurate measurement of hydrogen-ion activity [J].
Hamer, WJ ;
Acree, SF .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1939, 23 :647-662
[10]   The electromotive forces of uni-univalent halides in concentrated aqueous solutions [J].
Harned, HS .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1929, 51 (1-4) :416-427