Regional differences of fMR signal changes induced by hyperventilation: Comparison between SE-EPI and GE-EPI at 3-T

被引:21
作者
Naganawa, S [1 ]
Norris, DG [1 ]
Zysset, S [1 ]
Mildner, T [1 ]
机构
[1] Nagoya Univ, Sch Med, Dept Radiol, Shouwa Ku, Nagoya, Aichi 4668550, Japan
关键词
hyperventilation; functional; magnetic resonance; spin-echo; gradient-echo; vascular reactivity;
D O I
10.1002/jmri.10028
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate whether reproducible signal change of brain tissues by hyperventilation (HV) can be seen on spin-echo (SE)-echo planar imaging (EPI) at 3-T and to examine the sensitivity of SE-EPI for measuring vascular reactivity in regions of the brain, such as the hippocampal formation, that are difficult to visualize with gradient-echo (GE)-EPI due to susceptibility artifacts. Materials and Methods: Six healthy human subjects performed a voluntary HV task. The task design was as follows: two minutes normal breathing (rest) followed by two minutes HV, giving a basic four-minute block that was repeated three times for a total scan time of 12 minutes for one run. Each subject performed the run both for SE-EPI and GE-EPI. Statistical analysis was performed to detect the area with significant cerebrovascular reactivity. The percentage signal change was also obtained for each cerebral region. Results: Both GE-EPI and SE-EPI showed globally significant signal decreases in the cerebral cortex. In GE-EPI, the frontal cortex showed a larger signal decrease than the other gray matter tissues (P < 0.05). In SE-EPI, the differences among gray matter tissues except for the hippocampal formation were not significant. The hippocampal formation showed the largest signal change (P < 0.05) in SE-EPI, but no significant signal change was observed in GE-EPI due to the presence of susceptibility artifacts. Conclusion: HV using SE-EPI at 3-T provides robust and reproducible signal decreases and may make the evaluation of the vascular reactivity in hippocampal formation feasible.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 47 条
[1]   SPIN-ECHO AND GRADIENT-ECHO EPI OF HUMAN BRAIN ACTIVATION USING BOLD CONTRAST - A COMPARATIVE-STUDY AT 1.5 T [J].
BANDETTINI, PA ;
WONG, EC ;
JESMANOWICZ, A ;
HINKS, RS ;
HYDE, JS .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :12-20
[2]   EFFECTS OF BIOPHYSICAL AND PHYSIOLOGICAL-PARAMETERS ON BRAIN ACTIVATION-INDUCED R(2)ASTERISK AND R(2) CHANGES - SIMULATIONS USING A DETERMINISTIC DIFFUSION-MODEL [J].
BANDETTINI, PA ;
WONG, EC .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (2-3) :133-152
[3]   HYPERVENTILATION-INDUCED REDUCTION IN CEREBRAL BLOOD-FLOW - ASSESSMENT BY POSITRON EMISSION TOMOGRAPHY [J].
BEDNARCZYK, EM ;
RUTHERFORD, WF ;
LEISURE, GP ;
MUNGER, MA ;
PANACEK, EA ;
MIRALDI, FD ;
GREEN, JA .
DICP-THE ANNALS OF PHARMACOTHERAPY, 1990, 24 (05) :456-460
[4]  
Bosch V, 2000, J MAGN RESON IMAGING, V11, P61, DOI 10.1002/(SICI)1522-2586(200001)11:1<61::AID-JMRI9>3.0.CO
[5]  
2-C
[6]   THE INTRAVASCULAR CONTRIBUTION TO FMRI SIGNAL CHANGE - MONTE-CARLO MODELING AND DIFFUSION-WEIGHTED STUDIES IN-VIVO [J].
BOXERMAN, JL ;
BANDETTINI, PA ;
KWONG, KK ;
BAKER, JR ;
DAVIS, TL ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :4-10
[7]   Dynamics of blood flow and oxygenation changes during brain activation: The balloon model [J].
Buxton, RB ;
Wong, EC ;
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :855-864
[8]   FUNCTIONAL NMR IMAGING USING FAST SPIN-ECHO AT 1.5 T [J].
CONSTABLE, RT ;
KENNAN, RP ;
PUCE, A ;
MCCARTHY, G ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :686-690
[9]   Acetazolamide vasoreactivity in vascular dementia: A positron emission tomographic study [J].
De Reuck, J ;
Decoo, D ;
Hasenbroekx, MC ;
Lamont, B ;
Santens, P ;
Goethals, P ;
Strijckmans, K ;
Lemahieu, I .
EUROPEAN NEUROLOGY, 1999, 41 (01) :31-36
[10]  
FORTUNE JB, 1995, J TRAUMA, V39, P463