摘要
GATE is currently considered in scintigraphic imaging as a powerful tool to develop, design and optimize nuclear medicine modalities. This paper describes the GATE simulation of a pixelated gamma camera which is dedicated to high resolution of small animals imaging. It consists of a CsI(Na) crystal array coupled to position sensitive photomultiplier tube. The simulation model includes photon tracking through low energy high resolution hexagonal parallel holes collimator, CsI(Na) pixelated crystal, back-compartment, and camera shielding. Simulations were compared with experimental results by some criteria such as energy spectrum, energy resolution, spatial resolution, sensitivity and count profiles obtained from line and point sources imaging. The acquired energy resolution show good agreement with measured spectra. Difference between calculated and experimental values is about 0.3% for absolute sensitivity measurement. The result of the image uniformity is more consistent after implementation of non-uniformity correction. These values were about 1.3 and 1.2% for experimental and simulation study in the central field of view, respectively. Measurements showed that the spatial resolutions differences at the head surface along the long dimensions of gamma camera for simulation and experimental differed by no more than 4%.Differences along the short axis were about 6%. The FWHMs of images of point and line sources show good consistency between experimental images and corresponding simulated ones. The difference between experimental and simulated system parameters was within 11%. Our results demonstrate the ability and flexibility of the Monte Carlo simulation for modeling pixelated gamma camera with position sensitive detector by selecting the appropriate parameters for digitizer chain and collimator position on the detector surface.
引用
收藏
页码:31 / 39
页数:9
相关论文
共 50 条
  • [31] High resolution and sensitivity gamma camera with active septa. A first Monte Carlo study
    Ilisie, Victor
    Moliner, Laura
    Oliver, Sandra
    Sanchez, Filomeno
    Gonzalez, Antonio J.
    Seimetz, Michael
    Rodriguez-Alvarez, Maria J.
    Maria Benlloch, Jose
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [32] High resolution and sensitivity gamma camera with active septa. A first Monte Carlo study
    Victor Ilisie
    Laura Moliner
    Sandra Oliver
    Filomeno Sánchez
    Antonio J. González
    Michael Seimetz
    Maria J. Rodríguez-Álvarez
    Jose Maria Benlloch
    Scientific Reports, 9
  • [33] Monte Carlo simulation of a SPECT system: GATE, MCNPX or SIMIND? (a comparative study)
    Taheri, A.
    Heidary, S.
    Shahrabi, H.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [34] Performance estimation of high resolution SPECT for the human brain by Monte Carlo simulation of scintillation lights
    Hirano, Y.
    Zeniya, T.
    Watabe, H.
    Iida, H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3602 - 3605
  • [35] Performance estimation of high resolution SPECT for the human brain by Monte Carlo simulation of scintillation lights
    Hirano, Y.
    Zeniya, T.
    Watabe, H.
    Iida, H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3353 - 3356
  • [36] Monte Carlo simulation of a SPECT system: GATE, MCNPX or SIMIND? (a comparative study)
    Taheri, A.
    Heidary, S.
    Shahrabi, H.
    Journal of Instrumentation, 2017, 12 (12):
  • [38] Monte-Carlo simulation of pinhole collimator of a small field of view gamma camera for small animal imaging
    Zhu Jie
    Ma Wenyan
    Zhu Yufeng
    Ma Hongguang
    Wu Yuelei
    Hu Huasi
    Zhang Boping
    Huo Yonggang
    Liu Silu
    Han Bin
    Wang Zhaomin
    NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (01) : 37 - 41
  • [39] Optimization of pinhole collimator for small animal SPECT using Monte Carlo simulation
    Song, TY
    Choi, Y
    Chung, YH
    Jung, JH
    Choe, YS
    Lee, KH
    Kim, SE
    Kim, BT
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 811 - 815
  • [40] Performance evaluation of high-resolution square parallel-hole collimators with a CZT room temperature pixelated semiconductor SPECT system: a Monte Carlo simulation study
    Lee, Y.
    Kang, W.
    JOURNAL OF INSTRUMENTATION, 2015, 10