Development of GATE Monte Carlo simulation for a CsI pixelated gamma camera dedicated to high resolution animal SPECT

被引:11
|
作者
Taherparvar, Payvand [1 ]
Sadremomtaz, Alireza [1 ]
机构
[1] Univ Guilan, Dept Phys, Fac Sci, Namjoo Ave,POB 41635-1914, Rasht 4193833697, Gilan, Iran
关键词
GATE; Pixelated gamma camera; Spatial resolution; PET; VALIDATION; MODEL;
D O I
10.1007/s13246-017-0607-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
GATE is currently considered in scintigraphic imaging as a powerful tool to develop, design and optimize nuclear medicine modalities. This paper describes the GATE simulation of a pixelated gamma camera which is dedicated to high resolution of small animals imaging. It consists of a CsI(Na) crystal array coupled to position sensitive photomultiplier tube. The simulation model includes photon tracking through low energy high resolution hexagonal parallel holes collimator, CsI(Na) pixelated crystal, back-compartment, and camera shielding. Simulations were compared with experimental results by some criteria such as energy spectrum, energy resolution, spatial resolution, sensitivity and count profiles obtained from line and point sources imaging. The acquired energy resolution show good agreement with measured spectra. Difference between calculated and experimental values is about 0.3% for absolute sensitivity measurement. The result of the image uniformity is more consistent after implementation of non-uniformity correction. These values were about 1.3 and 1.2% for experimental and simulation study in the central field of view, respectively. Measurements showed that the spatial resolutions differences at the head surface along the long dimensions of gamma camera for simulation and experimental differed by no more than 4%.Differences along the short axis were about 6%. The FWHMs of images of point and line sources show good consistency between experimental images and corresponding simulated ones. The difference between experimental and simulated system parameters was within 11%. Our results demonstrate the ability and flexibility of the Monte Carlo simulation for modeling pixelated gamma camera with position sensitive detector by selecting the appropriate parameters for digitizer chain and collimator position on the detector surface.
引用
收藏
页码:31 / 39
页数:9
相关论文
共 50 条
  • [21] LumaGEM: High-resolution dedicated gamma camera
    MacDonald, LR
    Patt, BE
    Iwanczyk, JS
    McElroy, D
    Hoffman, EJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 56P - 56P
  • [22] Monte Carlo simulation of scatter effect for clinical gamma camera
    Saikouk, H.
    El Khayati, N.
    2014 MIDDLE EAST CONFERENCE ON BIOMEDICAL ENGINEERING (MECBME), 2014, : 305 - 308
  • [23] Effects of Crystal Pixel Size and Collimator Geometry on the Performance of a Pixelated Crystal gamma-Camera Using Monte Carlo Simulation
    Rasouli, Mahmoud
    Takavar, Abbas
    Ay, Mohammad Reza
    Saber, Sasan
    Loudos, George
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2010, 38 (04) : 199 - 204
  • [24] The effect of high-resolution parallel-hole collimator materials with a pixelated semiconductor SPECT system at equivalent sensitivities: Monte Carlo simulation studies
    Young-Jin Lee
    Dae-Hong Kim
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2014, 64 : 1055 - 1062
  • [25] The Effect of High-resolution Parallel-hole Collimator Materials with a Pixelated Semiconductor SPECT System at Equivalent Sensitivities: Monte Carlo Simulation Studies
    Lee, Young-Jin
    Kim, Dae-Hong
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (07) : 1055 - 1062
  • [26] Design and development of a high resolution animal SPECT scanner dedicated for rat and mouse imaging
    Sajedi, Salar
    Zeraatkar, Navid
    Moji, Vahideh
    Farahani, Mohammad Hossein
    Sarkar, Saeed
    Arabi, Hossein
    Teymoorian, Behnoosh
    Ghafarian, Pardis
    Rahmim, Arman
    Ay, Mohammad Reza
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 741 : 169 - 176
  • [27] Simulation of Intrinsic Resolution of Scintillation Camera in Monte Carlo Environment
    Dong, Xianling
    Saad, Wira Hidayat Mohd
    Adnan, Wan Azizun Wan
    Hashim, Suhairul
    Hassan, Nor Pai'za Mohd.
    Nordin, Abd Jalil
    Saripan, M. Iqbal
    2013 IEEE INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING APPLICATIONS (IEEE ICSIPA 2013), 2013, : 11 - 14
  • [28] Ultra High Resolution SPECT with CdTe for Small Animal Imaging applications: Monte Carlo Simulation Study Using Voxelized Phantom
    Park, Su Jin
    Lee, Chang-Lae
    Cho, Hyo-Min
    Kim, Hee-Joung
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3030 - 3033
  • [29] Quantitative validation of Monte Carlo SPECT simulation: application to a Mediso AnyScan GATE simulation
    Pells, Sophia
    Cullen, David M.
    Deidda, Daniel
    Denis-Bacelar, Ana M.
    Fenwick, Andrew
    Ferreira, Kelley M.
    Hamilton, David
    Heetun, Warda
    Julyan, Peter
    Needham, George
    Pietras, Ben
    Price, Emlyn
    Scuffham, James
    Tipping, Jill
    Robinson, Andrew P.
    EJNMMI PHYSICS, 2023, 10 (01)
  • [30] Quantitative validation of Monte Carlo SPECT simulation: application to a Mediso AnyScan GATE simulation
    Sophia Pells
    David M. Cullen
    Daniel Deidda
    Ana M. Denis-Bacelar
    Andrew Fenwick
    Kelley M. Ferreira
    David Hamilton
    Warda Heetun
    Peter Julyan
    George Needham
    Ben Pietras
    Emlyn Price
    James Scuffham
    Jill Tipping
    Andrew P. Robinson
    EJNMMI Physics, 10