Using domain knowledge for robust and generalizable deep learning-based CT-free PET attenuation and scatter correction

被引:42
作者
Guo, Rui [1 ,2 ]
Xue, Song [3 ]
Hu, Jiaxi [3 ]
Sari, Hasan [3 ,4 ]
Mingels, Clemens [3 ]
Zeimpekis, Konstantinos [3 ]
Prenosil, George [3 ]
Wang, Yue [1 ,2 ]
Zhang, Yu [1 ,2 ]
Viscione, Marco [3 ]
Sznitman, Raphael [5 ,6 ]
Rominger, Axel [3 ]
Li, Biao [1 ,2 ]
Shi, Kuangyu [3 ,6 ,7 ]
机构
[1] Shanghai Jiao Tong Univ, Ruijin Hosp, Dept Nucl Med, Sch Med, Shanghai, Peoples R China
[2] Ruijin Ctr, Collaborat Innovat Ctr Mol Imaging Precis Med, Shanghai, Peoples R China
[3] Univ Bern, Dept Nucl Med, Inselspital, Bern Univ Hosp, Bern, Switzerland
[4] Siemens Healthcare AG, Adv Clin Imaging Technol, Lausanne, Switzerland
[5] Univ Bern, ARTORG Ctr, Bern, Switzerland
[6] Univ Bern, Ctr Artificial Intelligence Med CAIM, Bern, Switzerland
[7] Tech Univ Munich, Comp Aided Med Procedures & Augmented Real, Inst Informat I16, Munich, Germany
基金
中国国家自然科学基金; 瑞士国家科学基金会;
关键词
TIME-OF-FLIGHT; SIMULTANEOUS RECONSTRUCTION; RADIOMICS ANALYSIS; EMISSION; METASTASIS; IMAGES;
D O I
10.1038/s41467-022-33562-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Despite the potential of deep learning (DL)-based methods in substituting CT-based PET attenuation and scatter correction for CT-free PET imaging, a critical bottleneck is their limited capability in handling large heterogeneity of tracers and scanners of PET imaging. This study employs a simple way to integrate domain knowledge in DL for CT-free PET imaging. In contrast to conventional direct DL methods, we simplify the complex problem by a domain decomposition so that the learning of anatomy-dependent attenuation correction can be achieved robustly in a low-frequency domain while the original anatomy-independent high-frequency texture can be preserved during the processing. Even with the training from one tracer on one scanner, the effectiveness and robustness of our proposed approach are confirmed in tests of various external imaging tracers on different scanners. The robust, generalizable, and transparent DL development may enhance the potential of clinical translation. Deep learning-based methods have been proposed to substitute CT-based PET attenuation and scatter correction to achieve CT-free PET imaging. Here, the authors present a simple way to integrate domain knowledge in deep learning for CT-free PET imaging.
引用
收藏
页数:9
相关论文
共 59 条
[1]   Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT [J].
Alberts, Ian ;
Huenermund, Jan-Niklas ;
Prenosil, George ;
Mingels, Clemens ;
Bohn, Karl Peter ;
Viscione, Marco ;
Sari, Hasan ;
Vollnberg, Bernd ;
Shi, Kuangyu ;
Afshar-Oromieh, Ali ;
Rominger, Axel .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (08) :2395-2404
[2]   Deep learning-guided joint attenuation and scatter correction in multitracer neuroimaging studies [J].
Arabi, Hossein ;
Bortolin, Karin ;
Ginovart, Nathalie ;
Garibotto, Valentina ;
Zaidi, Habib .
HUMAN BRAIN MAPPING, 2020, 41 (13) :3667-3679
[3]   Role of Imaging in the Staging and Response Assessment of Lymphoma: Consensus of the International Conference on Malignant Lymphomas Imaging Working Group [J].
Barrington, Sally F. ;
Mikhaeel, N. George ;
Kostakoglu, Lale ;
Meignan, Michel ;
Hutchings, Martin ;
Mueeller, Stefan P. ;
Schwartz, Lawrence H. ;
Zucca, Emanuele ;
Fisher, Richard I. ;
Trotman, Judith ;
Hoekstra, Otto S. ;
Hicks, Rodney J. ;
O'Doherty, Michael J. ;
Hustinx, Roland ;
Biggi, Alberto ;
Cheson, Bruce D. .
JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (27) :3048-+
[4]   Attenuation correction in emission tomography using the emission data-A review [J].
Berker, Yannick ;
Li, Yusheng .
MEDICAL PHYSICS, 2016, 43 (02) :807-832
[5]   FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0 [J].
Boellaard, Ronald ;
Delgado-Bolton, Roberto ;
Oyen, Wim J. G. ;
Giammarile, Francesco ;
Tatsch, Klaus ;
Eschner, Wolfgang ;
Verzijlbergen, Fred J. ;
Barrington, Sally F. ;
Pike, Lucy C. ;
Weber, Wolfgang A. ;
Stroobants, Sigrid ;
Delbeke, Dominique ;
Donohoe, Kevin J. ;
Holbrook, Scott ;
Graham, Michael M. ;
Testanera, Giorgio ;
Hoekstra, Otto S. ;
Zijlstra, Josee ;
Visser, Eric ;
Hoekstra, Corneline J. ;
Pruim, Jan ;
Willemsen, Antoon ;
Arends, Bertjan ;
Kotzerke, Joerg ;
Bockisch, Andreas ;
Beyer, Thomas ;
Chiti, Arturo ;
Krause, Bernd J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (02) :328-354
[6]   PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients [J].
Burger, C ;
Goerres, G ;
Schoenes, S ;
Buck, A ;
Lonn, AHR ;
von Schulthess, GK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) :922-927
[7]   Head-to-head comparison of DFO* and DFO chelators: selection of the best candidate for clinical89Zr-immuno-PET [J].
Chomet, Marion ;
Schreurs, Maxime ;
Bolijn, Maria J. ;
Verlaan, Mariska ;
Beaino, Wissam ;
Brown, Kari ;
Poot, Alex J. ;
Windhorst, Albert D. ;
Gill, Herman ;
Marik, Jan ;
Williams, Simon ;
Cowell, Joseph ;
Gasser, Gilles ;
Mindt, Thomas L. ;
van Dongen, Guus A. M. S. ;
Vugts, Danielle J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (03) :694-707
[8]   JOINT ESTIMATION OF ACTIVITY DISTRIBUTION AND ATTENUATION MAP FOR TOF-PET USING ALTERNATING DIRECTION METHOD OF MULTIPLIER [J].
Chun, Se Young ;
Kim, Kyeong Yun ;
Lee, Jae Sung ;
Fessler, Jeffrey A. .
2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, :86-89
[9]   Evaluation of [89Zr]trastuzumab-PET/CT in differentiating HER2-positive from HER2-negative breast cancer [J].
Dehdashti, Farrokh ;
Wu, Ningying ;
Bose, Ron ;
Naughton, Michael J. ;
Ma, Cynthia X. ;
Marquez-Nostra, Bernadette V. ;
Diebolder, Philipp ;
Mpoy, Cedric ;
Rogers, Buck E. ;
Lapi, Suzanne E. ;
Laforest, Richard ;
Siegel, Barry A. .
BREAST CANCER RESEARCH AND TREATMENT, 2018, 169 (03) :523-530
[10]   Deep learning-based attenuation correction in the absence of structural information for whole-body positron emission tomography imaging [J].
Dong, Xue ;
Lei, Yang ;
Wang, Tonghe ;
Higgins, Kristin ;
Liu, Tian ;
Curran, Walter J. ;
Mao, Hui ;
Nye, Jonathon A. ;
Yang, Xiaofeng .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05)