Spectroflourimetric assessment of UO22+ by the quenching of the fluorescence intensity of Clopidogrel embedded in PMMA matrix

被引:32
作者
Elabd, A. A. [1 ]
Attia, M. S. [2 ,3 ]
机构
[1] Nucl & Radiol Regulatory Author, Nucl Safeguards & Phys Protect Dept, Cairo, Egypt
[2] Univ Jeddah, Fac Sci, Dept Chem, Jeddah, Saudi Arabia
[3] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
关键词
Optical sensor; Fluorescence quenching; Emission intensity; Clopidogrel; PMMA; LIQUID-LIQUID MICROEXTRACTION; ION-SELECTIVE ELECTRODES; OPTICAL SENSOR; BULK OPTODE; SPECTROPHOTOMETRIC DETERMINATION; URANIUM; URANYL; EXTRACTION; MEMBRANE; SAMPLES;
D O I
10.1016/j.jlumin.2015.08.007
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new fluorescent optical sensor for highly sensitive and selective assessment of UO22+ in aqueous samples was introduced. The response of the sensor is based on the fluorescence quenching of [( +)-(S)-methyl 2-(2-chlorophenyl)-2-(6,7-dihydrothieno[3,2-clpyridin-5(4H)-yl)acetatel (Clopidogrel) embedded in polymethylmethacrylate (PMMA) polymer by UO22+. The sensor displays; wide concentration range from 1.0 x 10(-9) to 4.0 x 10(-6) MOI L-1, limit of detection (LOD) and limit of quantification (LOQ) are 2.6 x 10(-10) and 7.8 x 10(-10) mol L-1, respectively with a relatively fast response time of less than 60 s. The present sensor was revealed good response characteristics with respect to stability, reproducibility, sensitive and selectivity. Also, the response and quenching mechanisms for the present sensor were discussed. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:313 / 318
页数:6
相关论文
共 48 条
[1]  
Alfimoy M.V., 1999, APPL FLUORESCENCE CH, P1999
[2]  
[Anonymous], 2005, URANIUM DRINKING WAT
[3]   Excited state interaction between Hydrochlorothiazide and europium ion in PMMA polymer and its application as optical sensor for Hydrochlorothiazide in tablet and serum samples [J].
Attia, M. S. ;
Othman, A. M. ;
Youssef, A. O. ;
El-Raghi, E. .
JOURNAL OF LUMINESCENCE, 2012, 132 (08) :2049-2053
[4]   Spectrofluorimetric Assessment of Doxycycline Hydrochloride in Pharmaceutical Tablets and Serum Sample Based on the Enhancement of the Luminescence Intensity of the Optical Sensor Sm3+ Ion (vol 21, pg 1739, 2011) [J].
Attia, M. S. ;
Mahmoud, W. H. ;
Ramsis, M. N. ;
Khalil, L. H. ;
Othman, A. M. ;
Hashem, S. G. ;
Mostafa, M. S. .
JOURNAL OF FLUORESCENCE, 2011, 21 (05) :2035-2035
[5]   Spectrofluorimetric Assessment of Metoclopramide Hydrochloride Using Terbium Doped in PMMA Matrix Optical Sensor [J].
Attia, M. S. ;
Othman, A. M. ;
Elraghi, E. ;
Aboul-Enein, Hassan Y. .
JOURNAL OF FLUORESCENCE, 2011, 21 (02) :739-745
[6]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[7]   REFLECTANCE PROBE FOR URANIUM(VI) BASED ON THE COLORIMETRIC INDICATOR ARSENAZO-III [J].
BAYLOR, LC ;
BUCHANAN, BR .
APPLIED SPECTROSCOPY, 1995, 49 (05) :679-681
[8]   Sequential determination of 210Po and uranium radioisotopes in drinking water by alpha-particle spectrometry [J].
Benedik, L. ;
Vasile, M. ;
Spasova, Y. ;
Waetjen, U. .
APPLIED RADIATION AND ISOTOPES, 2009, 67 (05) :770-775
[9]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[10]   DETERMINATION OF TRACES OF URANIUM WITH 1-(2-PYRIDYLAZO)-2-NAPHTHOL [J].
CHENG, KL .
ANALYTICAL CHEMISTRY, 1958, 30 (06) :1027-1030