Optimal Design of Hybrid PV-Battery System in Residential Buildings: End-User Economics, and PV Penetration

被引:22
作者
Worighi, Imane [1 ,2 ,3 ,4 ]
Geury, Thomas [1 ,2 ,3 ]
El Baghdadi, Mohamed [1 ,2 ,3 ]
Van Mierlo, Joeri [1 ,2 ,3 ]
Hegazy, Omar [1 ,2 ,3 ]
Maach, Abdelilah [4 ]
机构
[1] VUB, ETEC Dept, Pleinlaan 2, B-1050 Brussels, Belgium
[2] VUB, MOBI Res Grp 2, Pleinlaan 2, B-1050 Brussels, Belgium
[3] Flanders Make, B-3001 Heverlee, Belgium
[4] Mohammed V Univ Rabat, Mohammadia Sch Engineers, Rabat 10106, Morocco
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 05期
关键词
multi-objective optimization; Smart grid; Nano-grids; Renewable Energy Sources; Energy Storage Systems; cost-effectiveness analysis; Fuzzy Logic Controller; Genetic Algorithm; RENEWABLE ENERGY; ELECTRIC VEHICLES; OPTIMIZATION TECHNIQUES; GENETIC ALGORITHM; FREQUENCY CONTROL; FUZZY-LOGIC; STORAGE; MANAGEMENT; POWER; COST;
D O I
10.3390/app9051022
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper proposes an optimal design for hybrid grid-connected Photovoltaic (PV) Battery Energy Storage Systems (BESSs). A smart grid consisting of PV generation units, stationary Energy Storage Systems (ESSs), and domestic loads develops a multi-objective optimization algorithm. The optimization aims at minimizing the Total Cost of Ownership (TCO) and the Voltage Deviation (VD) while considering the direct and indirect costs for the prosumer, and the system stability with regard to intermittent PV generation. The optimal solution for the optimization of the PV-battery system sizing with regard to economic viability and the stability of operation is found while using the Genetic Algorithm (GA) with the Pareto front. In addition, a fuzzy logic-based controller is developed to schedule the charging and discharging of batteries while considering the technical and economic aspects, such as battery State of Charge (SoC), voltage profile, and on/off-peak times to shave the consumption peaks. Thus, a hybrid approach that combines a Fuzzy Logic Controller (FLC) and the GA is developed for the optimal sizing of the combined Renewable Energy Sources (RESs) and ESSs, resulting in reductions of approximately 4% and 17% for the TCO and the VD, respectively. Furthermore, a sensitivity cost-effectiveness analysis of the complete system is conducted to highlight and assess the profitability and the high dependency of the optimal system configuration on battery prices.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Optimal Design Model for a Residential PV Storage System an Application to the Spanish Case
    Ballesteros-Gallardo, Juan Antonio
    Arcos-Vargas, Angel
    Nunez, Fernando
    SUSTAINABILITY, 2021, 13 (02) : 1 - 25
  • [32] Enhancement of maximum power point tracking technique based on PV-Battery system using hybrid BAT algorithm and fuzzy controller
    Pan, Zhen
    Nguyen Vu Quynh
    Ali, Ziad M.
    Dadfar, Sajjad
    Kashiwagi, Tetsuya
    JOURNAL OF CLEANER PRODUCTION, 2020, 274
  • [33] Model Predictive for Reactive Power Scheduling Control Strategy for PV-Battery Hybrid System in Competitive Energy Market
    Lupangu, Cedrick
    Justo, Jackson J.
    Bansal, Ramesh C.
    IEEE SYSTEMS JOURNAL, 2020, 14 (03): : 4071 - 4078
  • [34] An application of LAPO: Optimal design of a stand alone hybrid system consisting of WTG/PV/diesel generator/battery
    Shiva, Navid
    Rahiminejad, Abolfazl
    Nematollahi, Amin Foroughi
    Vahidi, Behrooz
    ADVANCES IN ENERGY RESEARCH, 2020, 7 (01): : 67 - 84
  • [35] Optimal sizing of hybrid PV-Wind-Battery storage system for Net Zero Energy Buildings to reduce grid burden
    Niveditha, N.
    Singaravel, M. M. Rajan
    APPLIED ENERGY, 2022, 324
  • [36] Multivariable Coordinated Nonlinear Gain Droop Control for PV-Battery Hybrid DC Microgrid Access System via a T-S Fuzzy Decision Approach
    Mao, Jingfeng
    Zhang Xiaotong
    Yin Chunyun
    Wu Aihua
    Zhang Xudong
    IEEE ACCESS, 2022, 10 : 89414 - 89427
  • [37] Scrutiny of multifarious particle swarm optimization for finding the optimal size of a PV/wind/battery hybrid system
    Maleki, Akbar
    Ameri, Mehran
    Keynia, Farshid
    RENEWABLE ENERGY, 2015, 80 : 552 - 563
  • [38] Increasing PV penetration level in low voltage distribution system using optimal installation and operation of battery energy storage
    Khaboot, Nathphol
    Chatthaworn, Rongrit
    Siritaratiwat, Apirat
    Surawanitkun, Chayada
    Khunkitti, Pirat
    COGENT ENGINEERING, 2019, 6 (01):
  • [39] Implementation of a novel hybrid BAT-Fuzzy controller based MPPT for grid-connected PV-battery system
    Ge, Xun
    Ahmed, Faraedoon Waly
    Rezvani, Alireza
    Aljojo, Nahla
    Samad, Sarminah
    Foong, Loke Kok
    CONTROL ENGINEERING PRACTICE, 2020, 98
  • [40] Hybrid PV and Battery System Sizing for Commercial Buildings in Malaysia: A Case Study of FKE-2 Building in UTeM
    Hossain, Jahangir
    Shareef, Hussain
    Hossain, Md. Alamgir
    Kalam, Akhtar
    Kadir, Aida Fazliana Abdul
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (03) : 4933 - 4945