Simultaneous determination of 13 aminoglycoside residues in foods of animal origin by liquid chromatography-electrospray ionization tandem mass spectrometry with two consecutive solid-phase extraction steps

被引:115
作者
Zhu, Wei-xia [1 ,2 ]
Yang, Ji-zhou [1 ]
Wei, Wei [1 ]
Liu, Ya-feng [1 ]
Zhang, Shu-sheng [2 ]
机构
[1] Henan Entry Exit Inspect & Quarantine Bur China, Zhengzhou 450003, Peoples R China
[2] Zhengzhou Univ, Dept Chem, Zhengzhou 450001, Peoples R China
关键词
Aminoglycosides; Animal-origin foods; LC-MS/MS; Solid-phase extraction; Residue analysis; Method validation;
D O I
10.1016/j.chroma.2008.08.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A confirmatory and quantitative method based on liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) has been developed for simultaneous determination of 13 aminoglycoside antibiotics in various samples. The aminoglycoside analytes were released and extracted from different matrices with 5% trichloroacetic acid. The influence of pH values on the solid-phase exaction (SPE) procedure has been studied. Due to different pK(a) values of the compounds, seven aminoglycosides (AGs) were quantitatively retained on Oasis HLB cartridges at pH < 1 and then six aminoglycosides were retained at pH 8.5. Thus, the combination of two HLB SPE cartridges with different pH values was involved to simultaneously purify 13 aminoglycosides. The proposed two SPE steps produced high recovery yields for every aminoglycoside in five different matrices. The LC-MS/MS method was validated according to the European Union Commission directive 2002/657/EC. Good performance characteristics were obtained for recovery, precision, calibration curve, stability, specificity, decision limits (CC alpha) and detection capabilities (CC beta) in different matrices. The optimized procedure has been successfully applied to real samples in our laboratories (n >= 200) for 1 year. It demonstrated that the new method was robust and useful for identification and quantification of 13 aminoglycosides residues in foods of animal origin. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 26 条
[1]  
Babin Y, 2007, J AOAC INT, V90, P1418
[2]   Simple confirmatory assay for analyzing residues of aminoglycoside antibiotics in bovine milk:: hot water extraction followed by liquid chromatography-tandem mass spectrometry [J].
Bogialli, S ;
Curini, R ;
Di Corcia, A ;
Laganà, A ;
Mele, M ;
Nazzari, M .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1067 (1-2) :93-100
[3]   Comparative study on the analytical performance of three waveforms for the determination of several aminoglycoside antibiotics with high performance liquid chromatography using amperometric detection [J].
Cai, YQ ;
Cai, W ;
Cheng, J ;
Mou, SF ;
Lu, YQ .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1085 (01) :124-130
[4]   Determination of gentamicin sulfate and related compounds by high-performance liquid chromatography with evaporative light scattering detection [J].
Clarot, I ;
Chaimbault, P ;
Hasdenteufel, F ;
Netter, P ;
Nicolas, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1031 (1-2) :281-287
[5]  
GRAHAM AE, 2006, J PHARM BIOMED ANAL, V40, P1114
[6]   Measurement of tobramycin by reversed-phase high-performance liquid chromatography with mass spectrometry detection [J].
Guo, MXM ;
Wrisley, L ;
Maygoo, E .
ANALYTICA CHIMICA ACTA, 2006, 571 (01) :12-16
[7]   Multi-screening approach to monitor and quantify 42 antibiotic residues in honey by liquid chromatography-tandem mass spectrometry [J].
Hammel, Yves-Alexis ;
Mohamed, Rayane ;
Gremaud, Eric ;
LeBreton, Marie-Helene ;
Guy, Philippe A. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1177 (01) :58-76
[8]   Quantitation of spectinomycin residues in bovine tissues by ion-exchange high-performance liquid chromatography with postcolumn derivatization and confirmation by reversed-phase high-performance liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry [J].
Hornish, RE ;
Wiest, JR .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :123-133
[9]  
Kaufmann A, 2005, J AOAC INT, V88, P1118
[10]   Development of liquid chromatographic method for the analysis of kanamycin residues in varicella vaccine using phenylisocyanate as a derivatization reagent [J].
Kim, BH ;
Kim, YK ;
Ok, JH .
JOURNAL OF CHROMATOGRAPHY B, 2001, 752 (01) :173-177