Aeolian Vibration and Its Suppression Methods of Long Crossing Span Overhead Electric Transmission line

被引:2
|
作者
Ji, Kunpeng [1 ]
Liu, Bin [1 ]
Wang, Jingchao [1 ]
Li, Peng [1 ]
Li, Danyu [1 ]
Zhang, Lichun [1 ]
Han, Jingshan [1 ]
Wang, Yifeng [2 ]
机构
[1] China Elect Power Res Inst, Dept Transmiss & Distribut, Beijing, Peoples R China
[2] State Grid Zhejiang Elect Power Co LTD, Res Inst Econ & Technol, Beijing, Peoples R China
来源
2019 6TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE 2019) | 2019年
关键词
overhead electric transmission line; wind induced vibration; aeolian vibration; long crossing span project; conductor; tubular tower;
D O I
10.1109/ICISCE48695.2019.00137
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
As the large-scale construction of AC-DC power grid project, the long crossing span projects of overhead electric transmission lines are increasing dramatically. Due to the particularity of the long crossing span project, the wind induced vibration has become one of the main factors threatening its structure safety. In this paper, the research progress of wind induced vibration of long crossing span conductor is summarized, the commonly used suppression schemes for wind induced vibration in the existing long crossing span projects are compared and the challenges in the research of wind induced vibration and its suppression are discussed. This paper is of great importance in engineering meaning to the systematic research of the wind induced vibration characteristics and anti-vibration technologies of long crossing span lines, to the comprehensive improvement of the design level of long crossing span lines against the wind induced vibration and to the protection of the safe and stable operation of power grid.
引用
收藏
页码:663 / 667
页数:5
相关论文
共 50 条
  • [21] VIBRATION BEHAVIOR OF OVERHEAD TRANSMISSION-LINE COMPONENTS IN THE PRESENCE OF CONDUCTOR VIBRATION
    GIESE, K
    ENERGIETECHNIK, 1978, 28 (11): : 433 - 437
  • [22] Forced Vibration of Overhead Transmission Line: Analytical and Experimental Investigation
    Barry, O.
    Zu, J. W.
    Oguamanam, D. C. D.
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2014, 136 (04):
  • [23] Fault Investigation and Analysis of an Overhead Transmission Line Vibration Damper
    Hickey, Conor
    Young, Paul
    Mayomi, Tolulope
    Noctor, Jason
    2021 56TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC 2021): POWERING NET ZERO EMISSIONS, 2021,
  • [24] Analysis of Dicing Techniques and Methods of Overhead Transmission Line
    Lv, Xifeng
    He, Qing
    CEIS 2011, 2011, 15
  • [25] ANALYSIS OF ELECTRIC FIELD IN 330 kV OVERHEAD TRANSMISSION LINE
    Deltuva, Ramunas
    Virbalis, Juozapas Arvydas
    Zebrauskas, Stasys
    ELECTRICAL AND CONTROL TECHNOLOGIES, 2011, : 255 - 259
  • [26] Optimal mechanical sag estimator for leveled span overhead transmission line conductor
    Kumar, Pradeep
    Singh, Asheesh K.
    MEASUREMENT, 2019, 137 : 691 - 699
  • [27] Response characteristics for aeolian vibration of long-span conductors under local excitation
    Chen X.-J.
    Wang Z.-Q.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2021, 34 (02): : 262 - 270
  • [28] Analysis of Vibration Characteristics for Overhead Transmission Line based on the Finite Model
    Fan Lijiang
    Yangguofeng
    Xue Bin
    Du Jia
    Li Shudong
    PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING, 2016, 53 : 390 - 397
  • [29] Analysis of Vibration Characteristics for Overhead Transmission Line based on the Finite Model
    Zhang Guojun
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON MEASUREMENT, INSTRUMENTATION AND AUTOMATION (ICMIA 2016), 2016, 138 : 262 - 269
  • [30] Ice shedding and vibration suppression of a transmission line system
    Yang, Feng-Li
    Yang, Jing-Bo
    Li, Zheng
    Han, Jun-Ke
    Fu, Dong-Jie
    Zhendong yu Chongji/Journal of Vibration and Shock, 2010, 29 (05): : 20 - 25