A low-cost particle counter as a realtime fine-particle mass monitor

被引:96
作者
Northcross, Amanda L. [1 ]
Edwards, Rufus J. [2 ]
Johnson, Michael A. [3 ]
Wang, Zhong-Min [4 ]
Zhu, Kunning [4 ]
Allen, Tracy [5 ]
Smith, Kirk R. [1 ]
机构
[1] Univ Calif Berkeley, Sch Publ Hlth, Dept Environm Hlth Sci, Berkeley, CA 94720 USA
[2] Univ Calif Irvine, Sch Med, Irvine, CA 92717 USA
[3] Berkeley Air Monitoring Grp, Berkeley, CA USA
[4] Calif Dept Publ Hlth, Environm Hlth Lab, Richmond, CA 94804 USA
[5] Elect Monitored Ecosyst, Berkeley, CA 94710 USA
关键词
PARTICULATE AIR-POLLUTION; MORTALITY; ASSOCIATION; SYMPTOMS; EXPOSURE; ASTHMA;
D O I
10.1039/c2em30568b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Exposure to particles with aerodynamic diameters less than 2.5 mu m is estimated to cause significant morbidity and mortality worldwide leading many countries to develop ambient air pollution standards and guidelines. At local scales, community and environmental justice groups are also concerned about PM2.5 concentrations that may be elevated above regional concentrations typically measured by centrally located monitors and standards as well. In an attempt to develop a low cost, easy to use monitor we evaluated a low-cost optical particle counter, the Dylos (TM), as a fine particulate mass sensor. Modified into a system called the Berkeley Aerosol Information Recording System (BAIRS), we compared performance against standard commercial instruments in chambers using polystyrene latex spheres, ammonium sulphate, and woodsmoke and in an urban ambient setting. Overall we find that the limit of detection of the BAIRS is less than 1 mu g m(-3) and the resolution is better than 1 mu g m(-3) for PM2.5. The BAIRS sizes small (<0.5 mu m) particles, and is able to accurately estimate the mass concentration of particles of varying composition including organic, inorganic, and ambient particles. It is able to measure concentrations up to 10.0 mg m(-3). In an ambient roof-top test of the BAIRS and a more expensive commercially available light scattering particle monitor the BAIRS response tracked well with the commercial monitor and daily means were within 80% of each other. We conclude that with appropriate modification the system could be developed into an accurate low cost realtime particle mass monitor for use in a wide range of applications.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 19 条
[1]  
[Anonymous], 2005, OZ NITR DIOX SULF DI
[2]  
[Anonymous], 2004, Comparative quantification of health risks: global and regional burden of disease attributable to selected major risk factors
[3]  
[Anonymous], PARTICLE SENSOR RELA
[4]  
[Anonymous], J GEOPHYS RES
[5]  
Baron P.A., 2011, Aerosol measurement: principles, techniques, and applications
[6]   An inexpensive light-scattering particle monitor: field validation [J].
Chowdhury, Zohir ;
Edwards, Rufus D. ;
Johnson, Michael ;
Shields, Kyra Naumolf ;
Allen, Tracy ;
Canuz, Eduardo ;
Smith, Kirk R. .
JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (10) :1099-1106
[7]   Temporal patterns in daily measurements of inorganic and organic speciated PM2.5 in Denver [J].
Dutton, Steven J. ;
Rajagopalan, Balaji ;
Vedal, Sverre ;
Hannigan, Michael P. .
ATMOSPHERIC ENVIRONMENT, 2010, 44 (07) :987-998
[8]   Geographies of risk in studies linking chronic air pollution exposure to health outcomes [J].
Jerrett, M ;
Finkelstein, M .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2005, 68 (13-14) :1207-1242
[9]   Spatial analysis of air pollution and mortality in Los Angeles [J].
Jerrett, M ;
Burnett, RT ;
Ma, RJ ;
Pope, CA ;
Krewski, D ;
Newbold, KB ;
Thurston, G ;
Shi, YL ;
Finkelstein, N ;
Calle, EE ;
Thun, MJ .
EPIDEMIOLOGY, 2005, 16 (06) :727-736
[10]   Comparison of sources of submicron particle number concentrations measured at two sites in Rochester, NY [J].
Kasumba, John ;
Hopke, Philip K. ;
Chalupa, David C. ;
Utell, Mark J. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2009, 407 (18) :5071-5084