Patient dosimetry in diagnostic and interventional radiology: A practical approach using trigger levels

被引:11
作者
Faulkner, K
Ortiz-Lopez, P
Vano, E
机构
[1] Qual Assurance Reference Ctr, Wallsend NE28 9ND, Tyne & Wear, England
[2] Int Atom Agcy, A-1400 Vienna, Austria
[3] Univ Complutense, Med Phys Serv, San Carlos Univ Hosp, E-28040 Madrid, Spain
[4] Univ Complutense, Dept Radiol, Sch Med, E-28040 Madrid, Spain
关键词
D O I
10.1093/rpd/nci737
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Patient dosimetry is performed in radiology and interventional radiology to assess whether deterministic injuries may occur and to establish the risk of stochastic effects. A fundamental problem for patient dosimetry is that no single quantity can be used to accurately assess both the risk of stochastic effects and whether deterministic injuries will occur following a specific examination or procedure. In cardiology and interventional radiology, two different approaches to patient dosimetry are commonly used. Effective dose is a quantity which correlates reasonably well with the risk of stochastic effects. Effective dose may be deduced from the dose-area product (DAP) for the procedure if sufficient information is known. DAP does not correlate with maximum skin dose, which may be used to predict whether deterministic injuries may occur. DAP meter readings may be used as a trigger level for the investigation of maximum skin entrance dose. Trigger levels for different procedures are proposed.
引用
收藏
页码:166 / 168
页数:3
相关论文
共 12 条
[1]  
[Anonymous], ICRP PUBL
[2]   Patient dosimetry measurement methods [J].
Faulkner, K ;
Broadhead, DA ;
Harrison, RM .
APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) :113-123
[3]   A new Diamentor for measuring kerma-area product and air-kerma simultaneously [J].
Gfirtner, H ;
Stieve, FE ;
Wild, J .
MEDICAL PHYSICS, 1997, 24 (12) :1954-1959
[4]  
Gleichmann U, 1997, Z KARDIOL, V86, P879
[5]   RADIATION-INDUCED TEMPORARY EPILATION AFTER A NEURORADIOLOGICALLY GUIDED EMBOLIZATION PROCEDURE [J].
HUDA, W ;
PETERS, KR .
RADIOLOGY, 1994, 193 (03) :642-644
[6]   Radiation-induced skin injuries from fluoroscopy [J].
Shope, TB .
RADIOGRAPHICS, 1996, 16 (05) :1195-1199
[7]  
Sovik E, 1996, ACTA RADIOL, V37, P305
[8]  
TAKEYAMA Y, 1997, MED DRUG J, V33, P2141
[9]   Skin radiation injuries in patients following repeated coronary angioplasty procedures [J].
Vano, E ;
Goicolea, J ;
Galvan, C ;
Gonzalez, L ;
Meiggs, L ;
Ten, JI ;
Macaya, C .
BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (887) :1023-1031
[10]   Dosimetric and radiation protection considerations based on some cases of patient skin injuries in interventional cardiology [J].
Vañó, E ;
Arranz, L ;
Sastre, JM ;
Moro, C ;
Ledo, A ;
Gárate, MT ;
Minguez, I .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (845) :510-516