Thermoeconomic analysis of a micro-CHP installation in a tertiary sector building through dynamic simulation

被引:54
作者
Campos-Celador, Alvaro [1 ]
Perez-Iribarren, Estibaliz [1 ]
Maria Sala, Jose [1 ]
Alfonso del Portillo-Valdes, Luis [1 ]
机构
[1] Univ Basque Courmy, ENEDI Res Grp, Bilbao, Spain
关键词
Thermoeconomics; Exergy; Micro-cogeneration; Dynamic simulation; TRNSYS; LIFE-CYCLE ASSESSMENT; EXERGOECONOMIC ANALYSIS; COGENERATION SYSTEMS; HEATING-SYSTEM; ENERGY; ALLOCATION; COSTS;
D O I
10.1016/j.energy.2012.01.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
A thermoeconomic analysis has been applied to the annual operation of a micro-cogeneration installation in a tertiary sector building combining the capabilities of dynamic simulation with the thermoeconomic analysis. The SenerTec's DACHS micro-cogeneration unit is considered integrated in a heating and domestic hot water installation, meeting the electric and thermal loads of a residential building. A six minute-based exergy analysis has been implemented in the TRNSYS v.16 thermal simulation software, while the Life Cycle Analysis (LCA) has been developed to determine the cumulative exergy consumption of the different components of the plant. The thermoeconomic analysis of the micro-CHP installation is performed for its annual operation which includes the analysis of the entire system, considering the costs and exergy content of both flows and components. The relationship between the annual contribution to the costs of the components and the energy consumption has resulted equal to 34.2%. A combined production cost value has been defined and has been compared with the micro-CHP unit and the conventional production system, being 34.6 and 45.42 c(sic)/kWh(ex) respectively, underlying the opportunity that micro-CHP units provide in residential installations. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 33 条
[21]   Thermoeconomic assessment of a multi-engine, multi-heat-pump CCHP (combined cooling, heating and power generation) system - A case study [J].
Roque Diaz, P. ;
Benito, Y. R. ;
Parise, J. A. R. .
ENERGY, 2010, 35 (09) :3540-3550
[22]   Exergetic analysis of cogeneration-based district energy systems [J].
Rosen, MA ;
Le, MN ;
Dincer, I .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2004, 218 (A6) :369-375
[23]   Allocating carbon dioxide emissions from cogeneration systems: descriptions of selected output-based methods [J].
Rosen, Marc A. .
JOURNAL OF CLEANER PRODUCTION, 2008, 16 (02) :171-177
[24]   Low exergy systems for high-performance buildings and communities [J].
Schmidt, Dietrich .
ENERGY AND BUILDINGS, 2009, 41 (03) :331-336
[25]  
SenerTec, SENERTECS DACHS TECH
[26]   INTERNATIONAL PROGRESS IN 2ND LAW ANALYSIS [J].
SZARGUT, J .
ENERGY, 1980, 5 (8-9) :709-718
[27]   EXERGOECONOMIC ANALYSIS AND EVALUATION OF ENERGY-CONVERSION PLANTS .1. A NEW GENERAL METHODOLOGY [J].
TSATSARONIS, G ;
WINHOLD, M .
ENERGY, 1985, 10 (01) :69-80
[28]   Exergoeconomic analysis and optimization of a solar-assisted heating system for residential buildings [J].
Ucar, A. ;
Inalli, M. .
BUILDING AND ENVIRONMENT, 2006, 41 (11) :1551-1556
[29]   Thermoeconomic analysis of energy utilization in the residential-commercial sector: An application [J].
Utlu, Zafer ;
Hepbasli, Arif .
BUILDING AND ENVIRONMENT, 2008, 43 (05) :896-904
[30]  
Valero A, 1986, ASME AES COMPUTER AI, V3, P1