摘要
Performance of two microbial fuel cells (MFCs) was investigated under batch and continuous mode of operation using different cathodic electrolyte. The wastewater was supplied from the bottom port provided to the anode chamber in both the MFCs and the effluent left the anode chamber from the top port in MFC-1, whereas in MFC-2, the effluent exit was provided close to membrane. Stainless steel (SS) mesh anode was used in both the MFCs with surface area of 167 and 100 cm(2) in MFC-1 and MFC-2, respectively. Under batch mode and continuous mode of operation, these MFCs gave chemical oxygen demand removal efficiency more than 85% and about 68%, respectively. Under batch mode of operation, maximum power density of 39.95 and 56.87 mW/m(2) and maximum current density of 180.83 and 295 mA/m(2) were obtained in MFC-1 and MFC-2, respectively. Under continuous mode of operation, a reduction in power and current density was observed. Even with less surface area of the anode, MFC-2 produced more current (1.77 mA) than MFC-1 (1.40 mA). Among the cathodic electrolyte tested, these can be listed in decreasing order of power density as aerated KMnO4 solution > KMnO4 solution without aeration > aerated tap water > aerated tap water with NaCl.
引用
收藏
页码:319 / 332
页数:14
相关论文
共 21 条
[1]   Production of bioenergy and biochemicals from industrial and agricultural wastewater [J].
Angenent, LT ;
Karim, K ;
Al-Dahhan, MH ;
Domíguez-Espinosa, R .
TRENDS IN BIOTECHNOLOGY, 2004, 22 (09) :477-485
[2]  
*APHA AWWA WPCF, 1998, STAND METH EX WAT WA
[3]   Oxygen exposure promotes fuel diversity for Shewanella oneidensis microbial fuel cells [J].
Biffinger, Justin C. ;
Byrd, Jacqueline N. ;
Dudley, Breanna L. ;
Ringeisen, Bradley R. .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (06) :820-826
[4]   Increased performance of single-chamber microbial fuel cells using an improved cathode structure [J].
Cheng, S ;
Liu, H ;
Logan, BE .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (03) :489-494
[5]   Performance of membrane-less microbial fuel cell treating wastewater and effect of electrode distance and area on electricity production [J].
Ghangrekar, M. M. ;
Shinde, V. B. .
BIORESOURCE TECHNOLOGY, 2007, 98 (15) :2879-2885
[6]   Operational parameters affecting the performance of a mediator-less microbial fuel cell [J].
Gil, GC ;
Chang, IS ;
Kim, BH ;
Kim, M ;
Jang, JK ;
Park, HS ;
Kim, HJ .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) :327-334
[7]   Construction and operation of a novel mediator- and membrane-less microbial fuel cell [J].
Jang, JK ;
Pham, TH ;
Chang, IS ;
Kang, KH ;
Moon, H ;
Cho, KS ;
Kim, BH .
PROCESS BIOCHEMISTRY, 2004, 39 (08) :1007-1012
[8]   Challenges in microbial fuel cell development and operation [J].
Kim, Byung Hong ;
Chang, In Seop ;
Gadd, Geoffrey M. .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2007, 76 (03) :485-494
[9]   Electricity generation using an air-cathode single chamber microbial fuel cell in the presence and absence of a proton exchange membrane [J].
Liu, H ;
Logan, BE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (14) :4040-4046
[10]   Power generation in fed-batch microbial fuel cells as a function of ionic strength, temperature, and reactor configuration [J].
Liu, H ;
Cheng, SA ;
Logan, BE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (14) :5488-5493