Extending ac-dc current transfer measurement to 100 A, 100 kHz

被引:8
|
作者
Rydler, Karl-Erik [1 ]
Tarasso, Valter [1 ]
机构
[1] SP Tech Res Inst Sweden, Boras, Sweden
来源
2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST | 2008年
关键词
D O I
10.1109/CPEM.2008.4574636
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the design and verification of current shunts for ac-dc transfer measurements in the range 20A to 100 A. The measured ac-dc current transfer difference of the 100 A shunt is -36 mu A/A at 100 kHz with an uncertainty of 200 mu A/A.
引用
收藏
页码:28 / 29
页数:2
相关论文
共 50 条
  • [1] Extending AC-DC Current Transfer to 100 A, 100 kHz in UME
    Arifovic, Mehedin
    Kanatoglu, Naylan
    Uzun, Serdar
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [2] Extension of the NIST AC-DC difference calibration service for current to 100 kHz
    Kinard, JR
    Lipe, TE
    Childers, CB
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1997, 102 (01) : 75 - 83
  • [3] 20-A to 100-A AC-DC coaxial current shunts for 100 kHz frequency range
    Filipski, Piotr S.
    Boecker, Michael
    Garcocz, Martin
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 518 - +
  • [4] 20-A to 100-A AC-DC coaial current shunts for 100-kHz frequency range
    Filipski, Piotr S.
    Boecker, Michael
    Garcocz, Martin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (08) : 1637 - 1641
  • [5] Characterization of AC-DC Transfer Shunts up to 100 A at 100 kHz Using Two-Stage, Amplifier-Aided Current Transformers
    Kinard, Joseph
    Laug, Owen
    Waltrip, Bryan
    Lipe, Thomas
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 107 - 110
  • [6] TEE CONNECTORS FOR AC-DC CURRENT SHUNTS UP TO 100 A
    Garcocz, M.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 591 - 592
  • [8] Establishment of High-Voltage AC-DC Voltage Transfer Standards in 1-100-kHz Range at NMIJ
    Fujiki, Hiroyuki
    Amagai, Yasutaka
    Okawa, Kenjiro
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (06) : 1921 - 1926
  • [9] 100A AC-DC current measurements to within ±25ppm from 3 Hz to 1kHz
    Clarke, KK
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2000, 147 (04) : 186 - 189
  • [10] AC-DC transfer difference measurement of AC shunts
    Konjevod, Jure
    Dadic, Martin
    Malaric, Roman
    Kunst, Ivica
    2018 FIRST INTERNATIONAL COLLOQUIUM ON SMART GRID METROLOGY (SMAGRIMET), 2018,