Effect of Porcelain Shade and Application Time on Shade Reproduction

被引:8
作者
Bahannan, Salma Ahmed [1 ]
Awad, Mohamed Abdelmageed [1 ]
机构
[1] King Abdulaziz Univ, Fac Dent, Oral & Maxillofacial Prosthodont Dept, Jeddah, Saudi Arabia
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2018年 / 27卷 / 03期
关键词
Color; ceramic; esthetics; restoration; technician; CERAMIC RESTORATIONS; COLOR; THICKNESS; ABILITY; ALLOYS; GUIDE;
D O I
10.1111/jopr.12498
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To determine the variability in shade reproduction of metal ceramic restorations fabricated by different laboratory technicians at different fabrication times. Materials and Methods: One hundred thirty five metal copings for metal ceramic restorations were fabricated with a standardized method and distributed among three dental laboratory technicians (n = 45). Each technician was requested to match three different shade specifications including 2L1.5, 3M2, 4R2.5 shade tabs of 3D Master shade guide following the manufacturer's instructions. The technicians were instructed to build up each shade 15 times using the same porcelain at three time periods namely first thing in the morning (T-1), middle of the work day (T-2), and at the end of the work day (T-3) (n = 5). Color difference (Delta E) was determined with a spectrophotometer. Each restoration was measured and recorded nine times. Data were tabulated and statistically analyzed using a univariate general linear model with Scheffe post hoc test, and one-way ANOVA at 5% level of significance Results: The color difference (Delta E) was significantly different among technicians, time of application, and shade matched. Technician 1 demonstrated good color reproduction for all shades in T-1. That was the same as technician 2 for shades 3M2 and 4R2.5, but the lighter shade (2L1.5) was better in T-2 and T-3. Technician 3 had better results at T-3. The lowest mean value of Delta E was calculated with technician 3 while the highest mean value was with technician 2. T-2 was associated with higher Delta E values in contrast to the other two times for technicians 1 and 2, while T-3 was associated with lower Delta E values for technicians 2 and 3. Conclusion: Within the limitations of this study, it can be concluded that the shade reproduction is affected by the time of porcelain application. The ability to reproduce the target shade differed among laboratory technicians. No specific time can be considered for all technicians to reproduce the shades with more accuracy.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 27 条
[1]  
Ahmad S, 2011, Pak Oral Dent J, V31, P222
[2]   Evaluation of self shade matching ability of dental students using visual and instrumental means [J].
AlSaleh, Samar ;
Labban, Manal ;
AlHariri, Morouj ;
Tashkandi, Esam .
JOURNAL OF DENTISTRY, 2012, 40 :E82-E87
[3]  
Anitha K V, 2013, J Indian Prosthodont Soc, V13, P296, DOI 10.1007/s13191-013-0267-5
[4]   Shade matching quality among dental students using visual and instrumental methods [J].
Bahannan, Salma A. .
JOURNAL OF DENTISTRY, 2014, 42 (01) :48-52
[5]  
Chu SJ, 2010, FUNDAMENTALS OF COLOR: SHADE MATCHING AND COMMUNICATION IN ESTHETIC DENTISTRY, SECOND EDITION, P1
[6]  
Chu Stephen J, 2007, Dent Clin North Am, V51, P473, DOI 10.1016/j.cden.2007.02.004
[7]   Variability of porcelain color reproduction by commercial laboratories [J].
Douglas, RD ;
Brewer, JD .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (04) :339-346
[8]   The influence of porcelain layer thickness on the final shade of ceramic restorations [J].
Dozic, A ;
Kleverlaan, CJ ;
Meegdes, M ;
van der Zel, J ;
Feilzer, AJ .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (06) :563-570
[9]   Color Variation Between Matched and Fabricated Shades of Different Ceramics [J].
Ghulman, Motaz Ahmed ;
Awad, Mohamed Abdelmageed .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (06) :472-477
[10]  
Ginzburg M, 2012, Refuat Hapeh Vehashinayim (1993), V29, P28