A disposable electrochemical sensor based on protein G for High-Density Lipoprotein (HDL) detection

被引:10
作者
Chammem, H. [1 ]
Hafaid, I. [1 ]
Bohli, N. [1 ]
Garcia, A. [3 ]
Meilhac, O. [4 ]
Abdelghani, A. [1 ]
Mora, L. [2 ]
机构
[1] Carthage Univ, Natl Inst Appl Sci & Technol, Dept Phys, Charguia 1080, Tunisia
[2] Univ Paris 13, Inst Galilee, Sorbonne Paris Cite, LVTS,INSERM,U1148, F-93430 Villetaneuse, France
[3] Univ Paris 13, Lab Sci Prod & Mat, Sorbonne Paris Cite, CNRS,UPR 3407, F-93430 Villetaneuse, France
[4] Univ La Reunion, CHU CIC La Reunion, INSERM, Diabet Atherothrombose Therapies Reunion Ocean In, St Denis, France
关键词
Protein G; HDL; AFM; Contact angle; Impedance spectroscopy; BIOMARKERS; PROTECTION; BIOSENSORS;
D O I
10.1016/j.talanta.2015.06.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, two biosensors were developed for the detection of High-Density Lipoproteins (HDL) particles, which are biomarkers inversely correlated with cardiovascular risk and which represent therapeutic targets for atherosclerosis. The electrochemical properties of the grafted antibody on interdigitated gold electrode were achieved by Impedance Spectroscopy (IS). The used deposition method was based on oriented antibody Anti-ApoA1 with an intermediate thin layer of protein G. The developed biosensor was able to detect both native plasma HDL and reconstituted HDL (rHDL) particles respectively with the detection limit of 50 ng/mL and 1 ng/mL, respectively. Dynamic contact angle and atomic force microscopy were used. The developed biosensors are able to differentiate the HDL particles according to their differences in size and interactions with the immobilized antibody. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:466 / 473
页数:8
相关论文
共 31 条
[1]  
[Anonymous], NATL VITAL STAT REP
[2]   Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework [J].
Atkinson, AJ ;
Colburn, WA ;
DeGruttola, VG ;
DeMets, DL ;
Downing, GJ ;
Hoth, DF ;
Oates, JA ;
Peck, CC ;
Schooley, RT ;
Spilker, BA ;
Woodcock, J ;
Zeger, SL .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 2001, 69 (03) :89-95
[3]  
Baccar H., 2014, J NANOMED NANOTECHNO, V5, P1
[4]  
Bhalla V., 2011, SENSOR ACTUAT B-CHEM, V161, P761
[5]   Comparative wettability study of polystyrene functionalized with different proteins [J].
Bouafsoun, Amira ;
Ponsonnet, Laurence ;
Kerkeni, Abdelhamid ;
Jaffrezic, Nicole ;
Othmane, Ali .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2007, 27 (04) :709-715
[6]  
Cai D, 2010, NAT NANOTECHNOL, V5, P597, DOI [10.1038/nnano.2010.114, 10.1038/NNANO.2010.114]
[7]  
Chammem H., 2014, J. Biomater. Nanobiotechnol, V5, P153, DOI [DOI 10.4236/JBNB.2014.53018, 10.4236/jbnb.2014.53018]
[8]   The current status of cancer biomarker research using tumour-associated antigens for minimal invasive and early cancer diagnostics [J].
Coronell, Johana A. Luna ;
Syed, Parvez ;
Sergelen, Khulan ;
Gyurjan, Istvan ;
Weinhaeusel, Andreas .
JOURNAL OF PROTEOMICS, 2012, 76 :102-115
[9]  
Finkelstein AV, 2014, Physics of protein molecules
[10]   Effect of electrical conditions on an impedimetric immunosensor based on a modified conducting polypyrrole [J].
Hafaid, Imen ;
Chebil, Syrine ;
Korri-Youssoufi, Hafsa ;
Bessueille, Francois ;
Errachid, Abdelhamid ;
Sassi, Zina ;
Ali, Zulfiqur ;
Abdelghani, Adnane ;
Jaffrezic-Renault, Nicole .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (01) :323-331