Internal flange stiffened moment connections with low-damage capability under seismic loading

被引:3
作者
Chou, Chung-Che [1 ,2 ]
Lo, Sheng-Wei [3 ]
Liou, Gin-Show [3 ]
机构
[1] Natl Taiwan Univ, Dept Civil Engn, Taipei 10764, Taiwan
[2] Natl Ctr Res Earthquake Engn, Taipei, Taiwan
[3] Natl Chiao Tung Univ, Dept Civil Engn, Hsinchu, Taiwan
关键词
IFS steel moment connection; Low-damage capability; Test; Finite element analysis; WELDED HAUNCH; STEEL BEAM; REHABILITATION; PERFORMANCE; PLATE; DESIGN; STATES;
D O I
10.1016/j.jcsr.2013.04.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study presents the seismic performance of steel moment connections using internal flange stiffeners (IFSs) welded at the face of the wide-flange column and inner side of the beam flange. The objective is to develop a steel moment connection that can achieve good seismic performance with low-damage capability during a large earthquake loading and minimize the repair cost. Four large-scale moment connections were tested to validate the cyclic performance. One connection which represented a welded-unreinforced flange-bolted web connection failed before finishing cyclic tests at a drift of 4%. Three IFS moment connections showed excellent performance and low damage after experiencing the AISC seismic load twice up to the target drift of 4%, without strength reduction. The specimens were also modeled using the computer program ABAQUS to further verify the effectiveness of the IFS in transferring beam moment to the column and to investigate potential sources of connection failure. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:38 / 47
页数:10
相关论文
共 19 条
[1]  
AISC, 2010, SEISM PROV STRUCT ST
[2]  
[Anonymous], 2009, ABAQUS US MAN VERS 6
[3]  
[Anonymous], 2000, FEMA350
[4]  
[Anonymous], 2006, STRUCTURAL WELDING C
[5]  
ASTM, 1988, SPEC STRUCT STEEL
[6]   Seismic rehabilitation of pre-Northridge steel moment connections: A case study [J].
Chi, Brandon ;
Uang, Chia-Ming ;
Chen, Albert .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (08) :783-792
[7]   Cyclic performance of a type of steel beam to steel-encased reinforced concrete column moment connection [J].
Chou, CC ;
Uang, CM .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2002, 58 (5-8) :637-663
[8]   Performance evaluation of steel reduced flange plate moment connections [J].
Chou, Chung-Che ;
Wu, Chia-Ching .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2007, 36 (14) :2083-2097
[9]   Seismic Rehabilitation of Welded Steel Beam-to-Box Column Connections Utilizing Internal Flange Stiffeners [J].
Chou, Chung-Che ;
Jao, Chih-Kai .
EARTHQUAKE SPECTRA, 2010, 26 (04) :927-950
[10]   Seismic rehabilitation performance of steel side plate moment connections [J].
Chou, Chung-Che ;
Tsai, Keh-Chyuan ;
Wang, Yuang-Yu ;
Jao, Chih-Kai .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (01) :23-44