Reproducibility of Nerve Fiber Layer Thickness Measurements Using 3D Fourier-Domain OCT

被引:84
作者
Menke, Marcel N. [1 ]
Knecht, Pascal [1 ]
Sturm, Veit [1 ]
Dabov, Simeon [2 ]
Funk, Jens [1 ]
机构
[1] Univ Zurich USZ, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[2] Univ Munster, Sch Med, Munster, Germany
关键词
D O I
10.1167/iovs.07-1435
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Conventional time-domain optical coherence tomography (OCT) has been shown to provide reproducible retinal nerve fiber layer (RNFL) measurements. Recently, high-speed, high-resolution Fourier-domain 3D-OCT has been introduced to improve OCT quality. It can provide 6-mm(2) high-density scans to provide RNFL thickness measurements. The purpose of this study was to test the reproducibility of 3D-OCT RNFL thickness measurements in healthy volunteers. METHODS. Thirty-eight eyes were included in the study. High-density 6-mm(2) 3D scans were registered by two independent operators. RNFL thickness was calculated for eight areas corresponding to the ETDRS areas and for two ring areas. The ETDRS grid was centered on the optic disc. Intraclass correlation coefficients (ICC) and coefficients of variation (COV) were calculated. Interobserver reproducibility was visualized by using Bland-Altman analysis. RESULTS. Intrasession reproducibility was good with a mean ICC of 0.90. The mean COV for operator 1 and 2 was 4.2% and 4%, respectively (range, 1.9%-6.7%). Highest reproducibility was found for the two ring areas and the superior and inferior quadrants. Mean differences in RNFL thickness measurements for ring 1 and 2 between operator 1 and 2 were 0.9 mu m (limits of agreement, -11.4 to +9.6 mu m) and 0.1 mu m (limits of agreement -4.1 to +3.9 mu m), respectively. CONCLUSIONS. 3D-OCT RNFL thickness measurements in healthy volunteers showed good intra- and interobserver reproducibility. 3D-OCT provides more RNFL thickness information compared to conventional time-domain OCT measurements and may be useful for the management of glaucoma and other optic neuropathies. (Invest Ophthalmol Vis Sci. 2008;49:5386-5391) DOI: 10.1167/iovs.07-1435
引用
收藏
页码:5386 / 5391
页数:6
相关论文
共 18 条
[1]   Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography [J].
Blumenthal, EZ ;
Williams, JM ;
Weinreb, RN ;
Girkin, CA ;
Berry, CC ;
Zangwill, LM .
OPHTHALMOLOGY, 2000, 107 (12) :2278-2282
[2]   Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments [J].
Bourne, RRA ;
Medeiros, FA ;
Bowd, C ;
Jahanbakhsh, K ;
Zangwill, LM ;
Weinreb, RN .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) :1280-1285
[3]   Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes [J].
Budenz, DL ;
Chang, RT ;
Huang, XR ;
Knighton, RW ;
Tielsch, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2440-2443
[4]   Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes [J].
Budenz, Donald L. ;
Fredette, Marie-Josee ;
Feuer, William J. ;
Anderson, Douglas R. .
OPHTHALMOLOGY, 2008, 115 (04) :661-666
[5]   Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes [J].
Carpineto, P ;
Ciancaglini, M ;
Zuppardi, E ;
Falconio, G ;
Doronzo, E ;
Mastropasqua, L .
OPHTHALMOLOGY, 2003, 110 (01) :190-195
[6]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[7]   Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning [J].
Gabriele, Michelle L. ;
Ishikawa, Hiroshi ;
Wollstein, Gadi ;
Bilonick, Richard A. ;
Kagemann, Larry ;
Wojtkowski, Maciej ;
Srinivasan, Vivek J. ;
Fujimoto, James G. ;
Duker, Jay S. ;
Schuman, Joel S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) :3154-3160
[8]  
Gurses-Ozden R, 1999, J GLAUCOMA, V8, P238
[9]   The Humphrey optical coherence tomography scanner: quantitative analysis and reproducibility study of the normal human retinal nerve fibre layer [J].
Jones, AL ;
Sheen, NJL ;
North, RV ;
Morgan, JE .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (06) :673-677
[10]  
Knighton RW, 2000, J GLAUCOMA, V9, P56