Impact of patient-prosthesis mismatch on 30-day outcomes in young and middle-aged patients undergoing aortic valve replacement

被引:13
作者
Hernandez-Vaquero, Daniel [1 ]
Llosa, Juan C. [1 ]
Diaz, Rocio [1 ]
Khalpey, Zain [2 ]
Morales, Carlos [1 ]
Alvarez, Ruben [1 ]
Lopez, Jose [1 ]
Boye, Francisco [3 ]
机构
[1] Hosp Univ Cent Asturias, Dept Cardiac Surg, Oviedo, Spain
[2] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Cardiac Surg, Boston, MA USA
[3] Harvard Univ, Sch Med, Children Hosp Boston, Dept Cardiac Surg, Boston, MA USA
来源
JOURNAL OF CARDIOTHORACIC SURGERY | 2012年 / 7卷
关键词
Patient-prosthesis mismatch; Severe aortic stenosis; ECHOCARDIOGRAPHIC DESCRIPTION; CLINICAL IMPACT; HEART-VALVE; MORTALITY; SURVIVAL; PERFORMANCE; PREVENTION; POSITION; EVENTS; SIZE;
D O I
10.1186/1749-8090-7-46
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The impact of patient-prosthesis mismatch (PPM) on early outcomes in young and middle-aged patients undergoing conventional aortic valve replacement for severe aortic stenosis remains unknown. Our objective was to evaluate the incidence of some degree of PPM and its influence on early mortality and morbidity. Methods: We analyzed our single center experience in all patients <70 years undergoing first-time isolated aortic valve replacement for severe stenosis in our center from September 2007 to September 2011. PPM was defined as an indexed effective orifice area <= 0,85 cm(2)/m(2). The influence of PPM on early mortality and postoperative complications was studied using propensity score analysis. Follow up at 30 postoperative days was 100% complete. Results: Of 199 patients studied, 61 (30,7%) had some degree of PPM. PPM was associated with an increased postoperative mortality (OR = 8,71; 95% CI = 1,67-45,29; p = 0,04) and major postoperative complications (OR = 2,96; CI = 1,03-8,55; p = 0,044). However, no association between PPM and prolonged hospital or ICU stay was demonstrated. Conclusions: Moderate PPM is a common finding in young and middle-aged patients undergoing surgery for aortic valve replacement due to severe stenosis. In addition, its influence on early outcomes may be relevant.
引用
收藏
页数:6
相关论文
共 23 条
  • [1] Apostolakis E, 2011, HELL J CARDIOL, V52, P41
  • [2] Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve
    Bach, DS
    Sakwa, MP
    Goldbach, M
    Petracek, MR
    Emery, RW
    Mohr, FW
    [J]. ANNALS OF THORACIC SURGERY, 2002, 74 (06) : 2003 - 2009
  • [3] Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    Blais, C
    Dumesnil, JG
    Baillot, R
    Simard, S
    Doyle, D
    Pibarot, P
    [J]. CIRCULATION, 2003, 108 (08) : 983 - 988
  • [4] Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method?
    Bleiziffer, Sabine
    Eichinger, Walter B.
    Hettich, Ina
    Guenzinger, Ralf
    Ruzicka, Daniel
    Bauernschmitt, Robert
    Lange, Ruediger
    [J]. HEART, 2007, 93 (05) : 615 - 620
  • [5] Association between indices of prosthesis internal orifice size and operative mortality after isolated aortic valve replacement
    Bridges, Charles R.
    O'Brien, Sean M.
    Cleveland, Joseph C.
    Savage, Edward B.
    Gammie, James S.
    Edwards, Fred H.
    Peterson, Eric D.
    Grover, Frederick L.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (04) : 1012 - +
  • [6] Routine enlargement of the small aortic root: A preventive strategy to minimize mismatch
    Castro, LJ
    Arcidi, JM
    Fisher, AL
    Gaudiani, VA
    [J]. ANNALS OF THORACIC SURGERY, 2002, 74 (01) : 31 - 36
  • [7] A randomized comparison of the MCRI On-X and CarboMedics Top Hat bileaflet mechanical replacement aortic valves: Early postoperative hemodynamic function and clinical events
    Chambers, J
    Roxburgh, J
    Blauth, C
    O'Riordan, J
    Hodson, F
    Rimington, H
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (03) : 759 - 764
  • [8] ECHOCARDIOGRAPHIC DESCRIPTION OF THE CARBOMEDICS BILEAFLET PROSTHETIC HEART-VALVE
    CHAMBERS, J
    CROSS, J
    DEVERALL, P
    SOWTON, E
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (02) : 398 - 405
  • [9] Chambers J, 2000, J HEART VALVE DIS, V9, P661
  • [10] Chambers J, 1998, J HEART VALVE DIS, V7, P569