The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium

被引:49
作者
Daniel, J [1 ]
Ziaee, H [1 ]
Salama, A [1 ]
Pradhan, C [1 ]
McMinn, DJW [1 ]
机构
[1] McMinn Ctr, Birmingham B15 3DP, W Midlands, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2006年 / 88B卷 / 04期
关键词
D O I
10.1302/0301-620x.88B4.17355
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The recent resurgence in the use of metal-on-metal bearings has led to fresh concerns over metal wear and elevated systemic levels of metal ions. In order to establish if bearing diameter influences the release of metal ions, we compared the whole blood levels of cobalt and chromium (at one year) and the urinary cobalt and chromium output (at one to three and four to six years) following either a 50 mm or 54 mm Birmingham hip resurfacing or a 28 mm Metasul total hip replacement. The whole blood concentrations and daily output of cobalt and chromium in these time periods for both bearings were in the same range and without significant difference.
引用
收藏
页码:443 / 448
页数:6
相关论文
共 25 条
[1]  
AHIER S, 1966, P I MECH ENG, V181, P137
[2]   RELIABILITY OF URINARY CREATININE AS A PARAMETER USED TO ADJUST VALUES OF URINARY BIOLOGICAL INDICATORS [J].
ALESSIO, L ;
BERLIN, A ;
DELLORTO, A ;
TOFFOLETTO, F ;
GHEZZI, I .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1985, 55 (02) :99-106
[3]   How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? [J].
Back, DL ;
Young, AA ;
Shimmin, AJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) :177-181
[4]   IN-VIVO TRANSPORT AND EXCRETION OF CORROSION PRODUCTS FROM ACCELERATED ANODIC CORROSION OF POROUS-COATED F75 ALLOY [J].
BROWN, SA ;
ZHANG, K ;
MERRITT, K ;
PAYER, JH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (08) :1007-1017
[5]  
Case CP, 2001, CLIN CHEM, V47, P275
[6]   A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty [J].
Cawley, J ;
Metcalf, JEP ;
Jones, AH ;
Band, TJ ;
Skupien, DS .
WEAR, 2003, 255 :999-1006
[7]  
Chan FW, 1999, CLIN ORTHOP RELAT R, P10
[8]   Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements [J].
Clarke, IC ;
Good, V ;
Williams, P ;
Schroeder, D ;
Anissian, L ;
Stark, A ;
Oonishi, H ;
Schuldies, J ;
Gustafson, G .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H4) :331-347
[9]   Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty [J].
Clarke, MT ;
Lee, PTH ;
Arora, A ;
Villar, RN .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06) :913-917
[10]   SOLUTION TREATMENT BEHAVIOR OF CO-CR-MO ALLOY [J].
CLEMOW, AJT ;
DANIELL, BL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1979, 13 (02) :265-279