Zenith p-branch standard fenestrated endovascular graft for juxtarenal abdominal aortic aneurysms

被引:83
|
作者
Kitagawa, Atsushi [1 ]
Greenberg, Roy K. [2 ]
Eagleton, Matthew J. [1 ]
Mastracci, Tara M. [1 ]
机构
[1] Cleveland Clin Fdn, Dept Vasc Surg, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44195 USA
关键词
REPORTING STANDARDS; CLINICAL-TRIAL; UNITED-STATES; STENT GRAFTS; HIGH-RISK; REPAIR; ENDOGRAFTS; MORTALITY;
D O I
10.1016/j.jvs.2012.12.087
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This article reports the early clinical outcomes and experiences of Zenith pivot branch device (p-branch) standard fenestrated endovascular graft (Cook, Bloomington, Ind) for treating juxtarenal abdominal aortic aneurysm (AAA) originating below the superior mesenteric artery (SMA). Methods: A physician-sponsored investigational device exemption study was used to assess enrolled elective and emergency patients from August 2011 to September 2012 for treatment with an off-the-shelf Zenith p-branch device. Patients were included provided an anatomic seal could be established 4 mm below the SMA and the renal geometry fit the protocol based on reconstructed computed tomography data. The celiac artery was addressed with a scallop and the SMA with an 8-mm fenestration. The renal fenestrations were constructed as a modified design to allow a range of renal locations (7.5 mm radially from the center of the fenestration) to be acceptably treated with a single configuration. Two anatomic configurations were created for renal arteries (origins at the same level, or disparate renal arteries with left lower than right). Outcomes are reported in coherence with endovascular reporting standards documents. Results: The study enrolled 16 patients (94% men; median age, 75 years [range, 59-87 years]) with a mean aneurysm size of 61 mm (range, 52-82 mm). Two were treated for aneurysm rupture. Technical success was achieved in all patients. The median fluoroscopy time was 62 minutes (range, 38-105 minutes), and the amount of contrast media was 69 mL (range, 31-121 mL). There were no aortic-related deaths, aneurysm ruptures, open surgical conversion, or type I/III endoleaks. One right renal artery occluded during follow-up in the setting of a conically shaped visceral aortic segment and was successfully treated with endovascular recanalization. Conclusions: The use of the p-branch device for aneurysms originating infra-SMA is associated with a high rate of technical success and minimal problems during the short follow-up duration. The off-the-shelf design allows for the treatment of ruptures and other urgent situations. Additional patients and more follow-up will be required to further define the risks and benefits of such a treatment strategy.
引用
收藏
页码:291 / 300
页数:10
相关论文
共 50 条
  • [1] Suitability of the Zenith p-Branch Standard Fenestrated Endovascular Graft for Treatment of Ruptured Abdominal Aortic Aneurysms
    Kristmundsson, Thorarinn
    Sveinsson, Magnus
    Bjorses, Katarina
    Tornqvist, Per
    Dias, Nuno
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (05) : 760 - 764
  • [2] Postapproval outcomes of juxtarenal aortic aneurysms treated with the Zenith fenestrated endovascular graft
    Vemuri, Chandu
    Oderich, Gustavo S.
    Lee, Jason T.
    Farber, Mark A.
    Fajardo, Andres
    Woo, Edward Y.
    Cayne, Neal
    Sanchez, Luis A.
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (02) : 295 - 300
  • [3] Technical aspects of repair of juxtarenal abdominal aortic aneurysms using the Zenith fenestrated endovascular stent graft
    Oderich, Gustavo S.
    Correa, Mateus P.
    Mendes, Bernardo C.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (05) : 1456 - 1461
  • [4] The compatibility of p-branch "off-the-shelf" fenestrated endovascular graft in Asian patients with juxtarenal aortic aneurysm
    Ou, Jiale
    Cheng, Stephen W. K.
    Chan, Yiu Che
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (06) : 1417 - 1423
  • [5] Applicability of Zenith p-branch Standard Fenestrated Endograft in Our Series
    Bargay-Juan, Pau
    Julian Gomez-Palones, Francisco
    Ariel Pepen-Moquete, Luis
    Plaza-Martinez, Angel
    Miguel Zaragoza-Garcia, Jose
    Mercedes Morales-Gisbert, Sara
    ANNALS OF VASCULAR SURGERY, 2016, 33 : 187 - 193
  • [6] Fenestrated Endovascular Repair for Pararenal or Juxtarenal Abdominal Aortic Aneurysms: a Systematic Review
    Mohamed, Naser
    Galyfos, George
    Anastasiadou, Christiana
    Sachmpatzidis, Ioannis
    Kikiras, Konstantinos
    Papapetrou, Anastasios
    Giannakakis, Sotirios
    Kastrisios, Georgios
    Papacharalampous, Gerasimos
    Geroulakos, Georgios
    Maltezos, Chrisostomos
    ANNALS OF VASCULAR SURGERY, 2020, 63 : 399 - 408
  • [7] Fenestrated endovascular aortic repair for juxtarenal abdominal aortic aneurysm
    Guo Wei
    Zhang Hong-peng
    Liu Xiao-ping
    Jia Xin
    Xiong Jiang
    Ma Xiao-hui
    CHINESE MEDICAL JOURNAL, 2013, 126 (03) : 409 - 414
  • [8] Anatomical Suitability of the Zenith Off-the-Shelf (p-Branch) Endograft in Juxtarenal Aortic Aneurysms Previously Treated Using the Chimney Technique
    Schroeder, Martin
    Donas, Konstantinos P.
    Stavroulakis, Konstantinos
    Stachmann, Arne
    Torsello, Giovanni
    Bisdas, Theodosios
    JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (02) : 223 - 229
  • [9] Juxtarenal aortic aneurysms: preliminary experience with fenestrated E-vita abdominal stent-graft
    Ricci, C.
    Ceccherini, C.
    Cini, M.
    Vigni, F.
    Leonini, S.
    Puliti, A.
    Benvenuti, A.
    Tucci, E.
    Tommasino, G.
    Muzzi, L.
    Neri, E.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2013, 54 (04): : 491 - 497
  • [10] Fenestrated EVAR for juxtarenal aortic aneurysms
    Stana, J.
    Fernandez Prendes, C.
    Konstantinou, N.
    Rantner, B.
    Banafsche, R.
    Tsilimparis, N.
    GEFASSCHIRURGIE, 2020, 25 (06): : 475 - 484