18FDG-positron emission tomography (PET) has a role to play in the diagnosis and therapy of infective endocarditis and cardiac device infection

被引:48
作者
Millar, B. Cherie [1 ]
Prendergast, Bernard D. [2 ]
Alavi, Abass [3 ]
Moore, John E. [1 ]
机构
[1] Belfast City Hosp, Dept Bacteriol, Northern Ireland Publ Hlth Lab, Belfast BT9 7AD, Antrim, North Ireland
[2] John Radcliffe Hosp, Dept Cardiol, Oxford OX3 9DU, England
[3] Univ Penn, Sch Med, Hosp Univ Penn, Dept Radiol,Div Nucl Med, Philadelphia, PA 19104 USA
关键词
Cardiac device; Culture-negative; Infective endocarditis; Pacemaker; Positron emission tomography (PET); Infection; FDG-PET; MOLECULAR DIAGNOSIS; POSITION STATEMENT; EUROPEAN-COUNCIL; MYCOTIC-ANEURYSM; VALVE INFECTION; AORTIC-VALVE; PACEMAKER; CARDIOLOGY; MEDICINE;
D O I
10.1016/j.ijcard.2012.12.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In recent years, molecular imaging with positron emission tomography (PET) and more recently, PET coupled with computed tomography (CT) have made a valuable impact in various clinical arenas, primarily within the field of oncology, but also in cardiovascular medicine, particularly in detecting coronary artery disease and myocardial viability. More recently, PET imaging has been proven useful in the diagnosis and evaluation of inflammation and infection at different organ sites. Application of PET in the case of Infective Endocarditis (IE) is still in its infancy and indeed the value of this application in the detection of vegetations is debated primarily due to sensitivity issues of the tracer in cardiac tissue and small vegetations. Interestingly, however, reports are now emerging highlighting the role that this application has played in the diagnosis, assessment of complications such as emboli and metastatic infection and the monitoring of therapeutic treatment of IE. More recently, PET/CT has proven valuable in the diagnosis and assessment of cardiac implantable electronic device (CIED)-related infection and its use has highlighted the contribution that this imaging modality may play in assessing the need for surgery in patients with such infections. This article reviews the literature with regard to the potential value of 2-deoxy-2-[F-18]fluoro-D-glucose ((18)FDG)-PET, as well as the pitfalls and limitations of this imaging modality, in relation to cardiac infection. The emerging role (18)FDG-PET/CT has in the diagnosis and monitoring of IE, particularly prosthetic valve IE and CIED-related infections should be considered, particularly in difficult cases. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1724 / 1736
页数:13
相关论文
共 75 条
[1]   Uptake of FDG in the area of a recently implanted bioprosthetic mitral valve [J].
Abidov, A ;
D'agnolo, A ;
Hayes, SW ;
Berman, DS ;
Waxman, AD .
CLINICAL NUCLEAR MEDICINE, 2004, 29 (12) :848-848
[2]   Infected pacemaker causing septic lung emboli detected on FDG PET/CT [J].
Abikhzer, Gad ;
Turpin, Sophie ;
Bigras, Jean-Luc .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (03) :514-515
[3]   PET: a revolution in medical imaging [J].
Alavi, A ;
Lakhani, P ;
Mavi, A ;
Kung, JW ;
Zhuang, HM .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2004, 42 (06) :983-+
[4]   PET scan in suspected but unproven pacemaker endocarditis [J].
Amraoui, Sana ;
Texier-Maugein, Jeannette ;
Bordachar, Pierre .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (02) :125-126
[5]   Update on Cardiovascular Implantable Electronic Device Infections and Their Management A Scientific Statement From the American Heart Association [J].
Baddour, Larry M. ;
Epstein, Andrew E. ;
Erickson, Christopher C. ;
Knight, Bradley P. ;
Levison, Matthew E. ;
Lockhart, Peter B. ;
Masoudi, Frederick A. ;
Okum, Eric J. ;
Wilson, Walter R. ;
Beerman, Lee B. ;
Bolger, Ann F. ;
Estes, N. A. Mark, III ;
Gewitz, Michael ;
Newburger, Jane W. ;
Schron, Eleanor B. ;
Taubert, Kathryn A. .
CIRCULATION, 2010, 121 (03) :458-477
[6]  
Baddour LM, 2005, CIRCULATION, V111, pE394, DOI 10.1161/CIRCULATIONAHA.105.165564
[7]  
Basu S, 2008, J NUCL MED, V49, p17N
[8]   Functional Imaging of Inflammatory Diseases Using Nuclear Medicine Techniques [J].
Basu, Sandip ;
Zhuang, Hongming ;
Torigian, Drew A. ;
Rosenbaum, Joshua ;
Chen, Wengen ;
Alavi, Abass .
SEMINARS IN NUCLEAR MEDICINE, 2009, 39 (02) :124-145
[9]   The detection of aortic valve infection by FDG-PET/CT in a patient with infection following total knee replacement [J].
Belohlavek, O ;
Votrubova, J ;
Skopalova, M ;
Fencl, P .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (04) :518-518
[10]   Cardiovascular Infection and Inflammation [J].
Ben-Haim, Simona ;
Gacinovic, Svetislav ;
Israel, Ora .
SEMINARS IN NUCLEAR MEDICINE, 2009, 39 (02) :103-114