Determination of the Dynamics of Healing at the Tissue-Implant Interface by Means of Microcomputed Tomography and Functional Apparent Moduli

被引:11
作者
Chang, Po-Chun [1 ,2 ]
Seol, Yang-Jo [1 ]
Goldstein, Steven A. [2 ,3 ]
Giannobile, William V. [1 ,2 ,4 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Coll Engn, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Sch Med, Dept Orthoped Surg, Ann Arbor, MI USA
[4] Univ Michigan, Sch Dent, Michigan Ctr Oral Hlth Res, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
biomechanics; dental implants; finite element analysis; microcomputed tomography; MICRO-COMPUTED TOMOGRAPHY; FINITE-ELEMENT-ANALYSIS; DENTAL IMPLANTS; BONE; OSSEOINTEGRATION; STABILITY; RADIOGRAPHY; INTEGRATION; PLACEMENT; ARTIFACTS;
D O I
10.11607/jomi.2614
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: It is currently a challenge to determine the biomechanical properties of the hard tissue-dental implant interface. Recent advances in intraoral imaging and tomographic methods, such as microcomputed tomography (micro-CT), provide three-dimensional details, offering significant potential to evaluate the bone-implant interface, but yield limited information regarding osseointegration because of physical scattering effects emanating from metallic implant surfaces. In the present study, it was hypothesized that functional apparent moduli (FAM), generated from functional incorporation of the peri-implant structure, would eliminate the radiographic artifact-affected layer and serve as a feasible means to evaluate the biomechanical dynamics of tissue-implant integration in vivo. Materials and Methods: Cylindric titanium mini-implants were placed in osteotomies and osteotomies with defects in rodent maxillae. The layers affected by radiographic artifacts were identified, and the pattern of tissue-implant integration was evaluated from histology and micro-CT images over a 21-day observation period. Analyses of structural information, FAM, and the relationship between FAM and interfacial stiffness (IS) were done before and after eliminating artifacts. Results: Physical artifacts were present within a zone of about 100 to 150 mu m around the implant in both experimental defect situations (osteotomy alone and osteotomy + defect). All correlations were evaluated before and after eliminating the artifact-affected layers, most notably during the maturation period of osseointegration. A strong correlation existed between functional bone apparent modulus and IS within 300 mu m at the osteotomy defects (r > 0.9) and functional composite tissue apparent modulus in the osteotomy defects (r > 0.75). Conclusion: Micro-CT imaging and FAM were of value in measuring the temporal process of tissue-implant integration in vivo. This approach will be useful to complement imaging technologies for longitudinal monitoring of osseointegration.
引用
收藏
页码:68 / 76
页数:9
相关论文
共 36 条
[1]  
ALBREKTSSON T, 1981, CLIN ORTHOP RELAT R, P269
[2]  
Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
[3]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[4]  
Berzins A, 1997, J BIOMED MATER RES, V34, P337
[5]   Biomechanical characterization of osseointegration:: An experimental in vivo investigation in the beagle dog [J].
Brånemark, R ;
Öhrnell, LO ;
Skalak, R ;
Carlsson, L ;
Brånemark, PI .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (01) :61-69
[6]   Ridge Preservation With or Without an Osteoinductive Allograft: A Clinical, Radiographic, Micro-Computed Tomography, and Histologic Study Evaluating Dimensional Changes and New Bone Formation of the Alveolar Ridge [J].
Brownfield, Lauren A. ;
Weltman, Robin L. .
JOURNAL OF PERIODONTOLOGY, 2012, 83 (05) :581-589
[7]  
Butz F, 2006, INT J ORAL MAX IMPL, V21, P687
[8]   PDGF-B gene therapy accelerates bone engineering and oral implant osseointegration [J].
Chang, P-C ;
Seol, Y-J ;
Cirelli, J. A. ;
Pellegrini, G. ;
Jin, Q. ;
Franco, L. M. ;
Goldstein, S. A. ;
Chandler, L. A. ;
Sosnowski, B. ;
Giannobile, W. V. .
GENE THERAPY, 2010, 17 (01) :95-104
[9]   Functional apparent moduli as predictors of oral implant osseointegration dynamics [J].
Chang, Po-Chun ;
Seol, Yang-Jo ;
Kikuchi, Noboru ;
Goldstein, Steven A. ;
Giannobile, William V. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 94B (01) :118-126
[10]  
Ersoy AE, 2008, J PERIODONTOL, V79, P1339, DOI [10.1902/jop.2008.080059, 10.1902/jop.2008.080059 ]