Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy

被引:62
|
作者
Lee, EK [1 ]
Fox, T
Crocker, I
机构
[1] Georgia Inst Technol, Sch Ind & Syst Engn, Ctr Operat Res Med, Atlanta, GA 30332 USA
[2] Emory Univ, Sch Med, Dept Radiat Oncol, Atlanta, GA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 64卷 / 01期
关键词
intensity-modulated radiation therapy; radiotherapy; optimization; mixed integer programming; beam angles; intensity map optimization;
D O I
10.1016/j.ijrobp.2005.08.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In current intensity-modulated radiation therapy (IMRT) plan optimization, the focus is on either finding optimal beam angles (or other beam delivery parameters such as field segments, couch angles, gantry angles) or optimal beam intensities. In this article we offer a mixed integer programming (MIP) approach for simultaneously determining an optimal intensity map and optimal beam angles for IMRT delivery. Using this approach, we pursue an experimental study designed to (a) gauge differences in plan quality metrics with respect to different tumor sites and different MIP treatment planning models, and (b) test the concept of critical-normal-tissue-ring-a tissue ring of 5 mm thickness drawn around the planning target volume (PTV)-and its use for designing conformal plans. Methods and Materials: Our treatment planning models use two classes of decision variables to capture the beam configuration and intensities simultaneously. Binary (0/1) variables are used to capture "on" or "off" or "yes" or "no" decisions for each field, and nonnegative continuous variables are used to represent intensities of beamlets. Binary and continuous variables are also used for each voxel to capture dose level and dose deviation from target bounds. Treatment planning models were designed to explicitly incorporate the following planning constraints: (a) upper/lower/mean dose-based constraints, (b) dose-volume and equivalent-uniform-dose (EUD) constraints for critical structures, (c) homogeneity constraints (underdose/overdose) for PTV, (d) coverage constraints for PTV, and (e) maximum number of beams allowed. Within this constrained solution space, five optimization strategies involving clinical objectives were analyzed: optimize total intensity to PTV, optimize total intensity and then optimize conformity, optimize total intensity and then optimize homogeneity, minimize total dose to critical structures, minimize total dose to critical structures and optimize conformity simultaneously. We emphasize that the objectives that include optimizing conformity make use of the critical-normal-tissue-ring. Three tumor sites: head-and-neck, pediatric brain, and prostate are used for comparison. Results: The ctitical-norinal-tissue-ring acts as a good device for enforcing conformity. Trends in the characteristics and quality of plans resulting from each model were observed. Attempts to reduce dose to critical structures tend to worsen PTV conformity (1.542 to 3.092) and homogeneity (1.223 to 1.984), depending on the relative size and spatial distance of the critical structures to the PTV. When the critical structures are relatively small compared with the PTV (as in the case for the pediatric brain tumor, where each is less than 15% in volume), dose reduction to critical structures is accompanied by much worse scores in conformity (2.482) and homogeneity (1.984). When the critical structures are larger, as in the case of head-and-neck (similar to 50%), the conformity and homogeneity deterioration is less significant (1.542 and 1.239, respectively). There is a clear tradeoff between homogeneity, conformity, and minimum dose to organs at risk (OARs). For head-and-neck and pediatric brain tumor, the model that minimizes total dose to critical structures and optimizes conformity simultaneously offers a compromise among these factors, resulting in reduced critical structure dose with conformal and homogeneous plans. In the prostate case, the tumor is smaller than the two large nearby critical structures, and all models provide very homogeneous PTV dose distribution. However, minimizing dose to critical structures worsens conformity, as it spreads the radiation to the area surrounding the PTV. The maximum dose to the critical structures also increases slightly. Compared with plans used in the clinic which generally have uniformly spaced beam angles, the optimal clinically acceptable plans obtained via the methods herein do not have equispaced beams. The optimal beam angles returned appear to be nonintuitive, and depend on PTV size and geometry and the spatial relationship between the tumor and critical structures. Conclusions: The MIP model described allows simultaneous optimization over the space of beamlet fluence weights and beam and couch angles. Based on experiments with tumor data, this approach can return good plans that are clinically acceptable and practical. This work distinguishes itself from recent IMRT research in several ways. First, in previous methods beam angles are selected before intensity map optimization. Herein, we employ 0/1 variables to model the set of candidate beams, and thereby allow the optimization process itself to select optimal beams. Second, instead of incorporating dose-volume criteria within the objective function as in previous work, herein, a combination of discrete and continuous variables associated with each voxel provides a mechanism to strictly enforce dose-volume criteria within the constraints. Third, using the construct of critical-normal-tissue-ring within the objective function can enhance the achievement of conformal plans. Based on the three tumor sites considered, it appears that volume and spatial geometry with respect to the PTV are important factors to consider when selecting objectives to optimize, and in estimating how well suited a particular model is for achieving a specified goal. (c) 2006 Elsevier Inc.
引用
收藏
页码:301 / 320
页数:20
相关论文
共 50 条
  • [21] Beam orientation optimization in intensity-modulated radiation treatment planning
    Pugachev, AB
    Boyer, AL
    Xing, L
    MEDICAL PHYSICS, 2000, 27 (06) : 1238 - 1245
  • [22] Decoding the Beam Complexity in Intensity-Modulated Radiation Therapy Plans
    Du, W.
    Cho, S.
    Zhang, X.
    Hoffman, K.
    Kudchadker, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 305 - +
  • [23] Optimal selection of beam orientations in intensity-modulated radiation therapy
    Wen, Ue-Pyng
    Yu, Ru-Siou
    Tsui, Che-Wei
    JOURNAL OF INDUSTRIAL AND PRODUCTION ENGINEERING, 2011, 28 (04) : 316 - 326
  • [24] Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming
    Yang, Ruijie
    Dai, Jianrong
    Yang, Yong
    Hu, Yimin
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (15): : 3653 - 3666
  • [25] Robust Beam Orientation Optimization for Intensity-Modulated Proton Therapy
    Gu, W.
    Neph, R.
    Ruan, D.
    Zou, J.
    Dong, L.
    Sheng, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E257 - E258
  • [26] Improving intensity-modulated radiation therapy using the anatomic beam orientation optimization algorithm
    Potrebko, Peter S.
    McCurdy, Boyd M. C.
    Butler, James B.
    El-Gubtan, Adel S.
    MEDICAL PHYSICS, 2008, 35 (05) : 2170 - 2179
  • [27] Reflections on beam configuration optimization for intensity-modulated proton therapy
    Cao, Wenhua
    Rocha, Humberto
    Mohan, Radhe
    Lim, Gino
    Goudarzi, Hadis M.
    Ferreira, Brigida C.
    Dias, Joana M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (13):
  • [28] Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming
    Yang, Ruijie
    Dai, Jianrong
    Yang, Yong
    Hu, Yimin
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1758 - +
  • [29] The Scatter Search Based Algorithm for Beam Angle Optimization in Intensity-Modulated Radiation Therapy
    Ghanbarzadeh, Ali
    Pouladian, Majid
    Monfared, Ali Shabestani
    Mahdavi, Seied Rabi
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2018, 2018
  • [30] Robust beam orientation optimization for intensity-modulated proton therapy
    Gu, Wenbo
    Neph, Ryan
    Ruan, Dan
    Zou, Wei
    Dong, Lei
    Sheng, Ke
    MEDICAL PHYSICS, 2019, 46 (08) : 3356 - 3370